Incoming Physical Laboratory Test Requests

Contract Laboratory has received the following Physical Laboratory Test Requests which need to be fulfilled! These Laboratory Test Requests are received from a variety of sources ranging from start-up companies to large, multinational Fortune 500 corporations, international organizations, well-respected universities and government agencies that are actively seeking Independent, Third-Party Physical Laboratories to perform their Physical Testing, Analysis, Assays, Product Development, Scientific Research Experiments, Inspections, Certifications, and Engineering Projects. If you are a Physical laboratory that would like more information on these Physical projects, please visit our registration page or call toll us free 1-855-377-6821.

Below are our 50 most recent Physical laboratory test requests. Please log in to see more.

Test Request 17-01790

Physical

Physical laboratory needed for OSHA testing verify heights and weights/limatations to OSHA 1926.701b
Testing U-Posts, T,Posts and Rebar. I would like a test performed dropping a 250lb bag of sand 3',5',8', and 10' also the same using a 200lb bag of sand

Submit Response

Test Request 17-01778

Physical

Pharmaceutical Analytical Chemistry Laboratory needed for conducting studies on the Active Pharmaceutical Ingredients APIs in an oil in water emulsion. We need to arrive at following conclusions by morphological/physical/chemical testing etc

1. Whether APIs are dispersed or solubilized (both APIs).
2. Phase in which each API is present (dispersed phase of emulsion or continuous phase of emulsion)
3. Particle size of API (for dispersed API). Separate PSD for each API if both are dispersed.
4. Globule size of emulsion.

Submit Response

Test Request 17-01751

Physical

Physical Laboratory needed for dimensional testing of pre-mold straight joings and pre-termination kits - 8.7/15 kV 3 core x 400sq mm Pre-Mold straight joints 2) 8.7/15 kV 3 core x 400sq mm Pre- Termination KitsPre- Termination Kits

Submit Response

Test Request 17-01690

Physical

Physical Laboratory needed for nut chipping testing using SAE J400 equipment of non-wovens.

Submit Response

Test Request 17-01519

Physical

Large Pharma needs polymer laboratory to study and develop new blends of polymers including the characterization (mechanical, physical) of the produced blends and supply of samples.

Closed

Test Request 17-01485

Physical

Medical device laboratory needed for physical testing of transfusion sets to the physical requirements of ISO 1135-4, Transfusion equipment for medical use -- Part 4: Transfusion sets for single use, gravity feed

Closed

Test Request 17-01355

Physical

Medical device laboratory needed for drug compatiblity testing and testing of parenteral IV containers to ISO 15747:2010 which contains requirements that relate to the safe handling and the physical, chemical and biological testing of plastic containers for parenterals.
ISO 15747:2010 is applicable to plastic containers for parenterals having one or more chambers and having a total nominal capacity in the range of 50 ml to 5 000 ml such as film bags or blow-moulded plastic bottles for direct administration of infusion (injection) solutions.

On the same lines I need to collaborate to test the following in my products:

(i) Ideal Uniform Self Collapsibility
(ii) logarithmic volume measurement for infused volume
(iii) No Exchange of Hazardous Contaminants with Environment
(iv) Residual Volume in Container
(v) No Suck Back in the container
(vi) No Contamination during Admixing
(vii) Drug Compatibility

Closed

Test Request 17-01338

Physical

Large corporation needs physical laboratory for failure analysis of injection molded waterproof housing submitted to a leak test, t. It has been observed that air bubbles are coming out at some locations that coincide with a knit line, there is a theory that the knit line is actually a mico crack that allow air to come out. I'd like to perform an x-ray of the area and then perform a cross section to determine how this knit line propagates if this in fact a microcrack.

Closed

Test Request 17-01189

Physical

URGENT Large company needs physical laboratory for environmental simulation testing of 2 pallets of products. Laboratory must have walk in environmental chamber capable of handling 2 pallets 42x42x48 to cycle for 3 weeks between 95%RH, 95% and 20%RH, 70F

Closed

Test Request 17-01146

Physical

Physical laboratory needed for SAE testing on fuel lines to SAE J2027 Standard for Protective Covers for Gasoline Fuel Line Tubing

Closed

Test Request 17-01139

Physical

Laboratory needed to measure thermo-physical properties of fuel additive mixtures containing ethylene, vinyl acetate and cyclohexane. Properties to measure include: critical point determination, viscosity of mixtures, density of mixtures, vapour pressures, compressibility factor, specific heat capacity, pressure-vapour temperature in liquid (supercritical and vapour phase), Vapour-liquid equilibrium data of mixtures

Closed

Test Request 17-01115

Physical

Physical laboratory needed for flame retardant testing to Information Technology Industry Council. standard 'M1', Biometrics

Closed

Test Request 17-01091

Physical

Construction materials laboratory needed for physical testing of Fiber Reinforced Polymer (FRP) Reinforcing Bar including 160 samples tested for durability in accordance with the following standards:

-AC320 (an acceptance criteria from ICC)
-Conditioned for 1000 and 3000 hours using ASTM D 2247
-ASTM C 581 Standard Practice for Testing Water Resistance of Coatings in 100?% Relative Humidity

Closed

Test Request 17-01011

Physical

URGENT Physical laboratory needed for ASTM composite testing to test method of ASTM E 756: Vibration Dampening Testing

The testing sample will be a 2-4 mm thick non-ferrous metal composite material.

Closed

Test Request 17-01006

Physical

Physical laboratory needed for basic drop/vibration ISTA testing of a lamp packaging in single parcel - 16.

Closed

Test Request 17-00951

Physical

Physical laboratory needed for EN fire safety testing (90min) for storage cabinets as per EN 14470, European
Standard for Safety Storage
Cabinets

Closed

Test Request 17-00908

Physical

LONG-TERM TESTING Physical laboratory needed for ASTM flammability testing of paint to ASTM D822 Open-Flame Carbon-Arc Exposures of Paint and Related Coatings, test to four 4x6 samples.

Closed

Test Request 17-00900

Physical

Medical device laboratory needed for physical ASTM testing of a range of titanium surgical-grade products to the following ASTM Standards: ASTM F2052 Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment, ASTM F2119 Test Method for Evaluation of MR Image Artifacts from Passive Implants, ASTM F2182 Test Method for Measurement of Radio Frequency Induced Heating On or Near Passive Implants During Magnetic Resonance Imaging, and ASTM F2213 Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment

Closed

Test Request 17-00888

Physical

Orthopedics medical device laboratory needed for physical certification testing of prosthetic devices to ISO10328 (Prosthetics - Structural) for a lower limb prosthesis

Closed

Test Request 17-00881

Physical

Medical Device Laboratory needed for microbiology and physical testing of medical drapes and surgical gowns to several EN ISO standards:
1. EN ISO 22612 Resistance to Microbial Penetration - Dry,
2. EN ISO 22610 Resistance to Microbial Penetration - Wet,
3. EN ISO 11737-1 Cleanliness - Microbial,
4. EN ISO 9073-10 Cleanliness - Particulate Matter/Linting,
5. EN 20811 Resistance to Liquid Penetration
6. EN ISO 13938-1 Bursting Strength - Dry,
7. EN ISO 13938-1 Bursting Strength - Wet,
8. EN 29073-3 Tensile Strength - Dry and,
9. EN 29073-3 Tensile Strength - Wet

Closed

Test Request 17-00720

Physical

University researcher needs physical laboratory for doppler radar vibration measurement of sensor, receiver and software to model the receiving data and any other related components.

Closed

Test Request 17-00712

Physical

LONG-TERM TESTING Lighting manufacturer needs physical laboratory for SAE and NFPA certification testing of LED lighting products to SAE J595, SAE J845, California Title 13, NFPA 1901-2009, KKK-A-1822F

Closed

Test Request 17-00696

Physical

LONG-TERM TESTING Pharmaceutical company needs physical chemistry laboratory for particle size analysis of bulk drug active pharmaceutical ingredient (API) using Malvern 2000 or 3000 (laser technique).

Closed

Test Request 17-00679

Physical

Automotive parts company needs physical materials laboratory for ASTM flammability testing to ASTM D6668 - 01(2016) Standard Test Method for Discrimination Between Flammability Ratings of F=0 and F=1

Closed

Test Request 17-00677

Physical

Medical Device company needs physical chemistry laboratory for surface tension and surface energy testing

Closed

Test Request 17-00672

Physical

ISO 17025 certified laboratory needed for OECD physical / chemical testing of solid materials and an octanol / water solution as per three OECD standard methods: OECD107 Partition Coefficient (n-octanol/water): shake flask method , OECD 117 Partition Coefficient (n-octanol/water), HPLC method, and OECD123 Partition Coefficient (1-octanol/water): slow-stirring method

Closed

Test Request 17-00652

Physical

LONG-TERM TESTING Materials laboratory needed for ASTM physical, mechanical, and accelerated aging testing of polymer auto parts to car manufacturers specifications WSS-M2D496 (Ford), GMW 14196 (General Motors), MS-AY-549 (Chrysler-Fiat) including:
WSS-M2D496
Density to ASTM D3574-16 Test A
Tensile Strength to ASTM D3574-16 Test E
Elongation at Break to ASTM D3574-16 Test E
Tear Strength to ASTM D624 Die C
Compression Set to ISO 1856 Method A
Compression Deflection Stress ISO 3386-1 +A1
Heat Aging to ASTM D3574-16 Test K, ISO 3386-1 +A1
Humidity Aging to ASTM D3574-16 Test J, ISO 3386-1 +A1
Dimensional Stability to WSS-M2D496, 3.5.10
Fogging to SAE J1756
Odor to FLTM BO 131-03 Variant B
Cold Flexibility to FLTM BN102-01 Method A
Solvent Resistance to WSS-M2D496
Flammability to ISO 3795
GMW 14196 Testing
Emissions per GMW 15634 (VOCs, SVOCs)
Emissions per GMW 15635 (Carbonyls)
Emissions per GMW 3205 (Odor)
Emissions per GMW 3235 (Fog)
Compression Force Deflection per ISO 3386-1 40% Compression
Mass per GMW 3182
Thickness per ISO 1923 or ISO 2589 depending on Type
Flammability per GMW 3232/FMVSS-302
MS-AY-549 Chrysler Fiat
Compression Deflection per ASTM D 3574-16 Test C 25% Compression
Aged Compression/Deflection Humidity Aged per ASTM D3574-16 Test C and J at 25% deflection
Aged Compression/Deflection Oven Aged per ASTM D3574-16 Test C and K at 25% deflection


Closed

Test Request 17-00650

Physical

Packaging laboratory needed for physical testing of pharmaceutical corrugated shippers including burst strength, compression strength, and moisture content

Closed

Test Request 17-00641

Physical

LONG-TERM TESTING Pharmaceutical analytical laboratory needed for in vitro release testing & physical characterization (viscosity and rheology) for drugs in solid oral dosage form.

Closed

Test Request 17-00626

Physical

Large electronics company needs product safety laboratory for fall hazard, structural integrity / physical stability / product safety testing of a commercial product to ensure it does not present "fall" or "tilt" hazard.

Closed

Test Request 17-00592

Physical

Packaging laboratory needed for physical testing of corrugated box for burst strength and edge crush tests.

Closed

Test Request 17-00574

Physical

Polymer laboratory needed for nondestructive NDT Testing: heat resistance testing of an acrylic lens according to IWA MIL-PRF-5425. Also, need physical properties such as elongation, tensile strength testing of O-rings made out of 51+/-5 durometer EP rubber compounds according to E5001B, E1100-50, EA454-50 or chemically equivalent.

Closed

Test Request 17-00529

Physical

Physical laboratory needed for mechanical durability testing of industrial glass tubes.

Closed

Test Request 17-00502

Physical

Physical chemistry laboratory needed for OECD testing to OECD Test No.123 Partition Coefficient (1-Octanol/Water): slow-stirring method or shake flask method.

Closed

Test Request 17-00501

Physical

Consumer product laboratory needed for physical testing of baby pacifier clip for length, Impact resistance, durability of the garment fastener, and tensile strength.

Closed

Test Request 17-00499

Physical

Aerospace company needs materials laboratory needed for polymer testing for the dielectric strength in cured poly-sulfide rubber.

Closed

Test Request 17-00485

Physical

Pharmaceutical laboratory needed for particle size determination of a pharmaceutical powder testing using an alpine air jet instrument.

Closed

Test Request 17-00480

Physical

Large industrial technology company needs electrical laboratory for IEC electrical performance and EMC testing of electrical substation relay to IEC 61810 or 60255 standards

Closed

Test Request 17-00461

Physical

Medical Device Laboratory needed for Acoustics and Bench Testing:  Sound Velocity, Acoustic Impedence, Sound Attenuation; Physical Measurements:  Viscosity, and Density of ultrasound gel

Closed

Test Request 17-00433

Physical

URGENT. Polymers laboratory needed for verification testing of the molecular weight of a Ultra-high-molecular-weight polyethylene (UHMWPE) polymer.

Closed

Test Request 17-00428

Physical

Physical chemistry laboratory needed for flash point testing of petroleum products in the temperature range from 40C to 370C by a manual Pensky-Martens Closed Cup Tester or an automated Pensky-Martens closed-cup apparatus.

Closed

Test Request 17-00417

Physical

Physical laboratory needed for DIN Testing of automotive parts to 5.9 Solar Radiation Test as per DIN 75220, D-OUT-F
Test duration 1 cycle = 240 hrs.
Test chamber temp = 42 oC, RH 65 %
Radiatlon intensity 1000 W/m2
Visual evaluation
5.10 Dust Test
- execution as per ISO 16750-1, resp. ISO 20653
- Preparing of the test samples; without sealing and without producing of testing 1 cycle:
- Swiriing of dust in chamber for 6s
- Dust deposits for 20 min - Total of 20 cycles
- Type of dust: Arizona dust A2
Operation mode 3.2 for 5 min (necessary to specify operating voltage)
- Evaluation - dismounting of sample and check of dust ingress (necessary to specify) - 1 sample tested in 1 load

Closed

Test Request 17-00401

Physical

Medical Device company needs microbiology laboratory for microbiological tests of diapers and underpads.

Closed

Test Request 17-00362

Physical

Water agency needs Metallurgical Laboratory needed for corrosion testing including pitting depth from corrosion on 1 Type K Soft copper tubing.

Closed

Test Request 17-00356

Physical

Plastics / Materials Laboratory needed for ASTM physical testing of plastic crates from different suppliers including:
Raw material tests as per ASTM D4976 + ASTM D5203, density, melt flow rate, elongation at break, tensile strength, UV resistance, stress crack resistant, impact test as per SASO-GSO 1863.

Closed

Test Request 17-00310

Physical

Pharmaceutical company needs Analytical Chemistry Laboratory needed for water vapor transmission testing for drug product.

Closed

Test Request 17-00306

Physical

Physical Laboratory needed for pressure drop and CFM airflow testing on HVAC cold air returns.

Closed

Test Request 17-00218

Physical

Physical laboratory needed for EN electrical wiring testing to
High temperature exposure EN 6059-302
Fluid Resistance EN 6059-303
Fluid absorption EN 6059-305
Dynamic cut through EN 6059-405
Mould growth EN 6059-306
Smoke density EN 2825 B
Tensile strength EN 6059-404

Closed

Business Request 17-0012

Physical

Wishing to purchase laboratories located near or around Central Jersey. Also, the laboratory could be purchased for licensing and moved. There are many different variables such as accreditation, insurance mix machine, and so on so I would be interested in looking at all opportunities. This would include any lab since Toxicology could be added. The price range is determined by the specific deal. Also if to only the lab could be purchased for the licensing and moved to a desirable location since servicing allows for distance from location with receiving samples of of state or geographic location of the physical lab.

Submit Response

Test Request 17-00030

Physical

Physical chemistry laboratory needed for quantitative structure activity relationships (QSAR) analysis of cosmetics containing silicone.

Closed

Test Request 17-00011

Physical

Polymer laboratory needed for EPA and ASTM materials testing of a O/W micro-emulsion matrixColor; Physical State; Odor; Explosive Properties; Oxidising Properties & Incompatibility; Flammability; pH; Non-Newtonian Fluid Dynamic Viscosity; Relative Density; Storage Stability at 54 C for 14 days and ASTM G31 Corrosion Characteristics.

Closed

Submit Physical Testing Requests for Physical testing and Physical Scientific Research