Incoming Optics Laboratory Test Requests

Contract Laboratory has received the following Optics Laboratory Test Requests which need to be fulfilled! These Laboratory Test Requests are received from a variety of sources ranging from start-up companies to large, multinational Fortune 500 corporations, international organizations, well-respected universities and government agencies that are actively seeking Independent, Third-Party Optics Laboratories to perform their Optics Testing, Analysis, Assays, Product Development, Scientific Research Experiments, Inspections, Certifications, and Engineering Projects. If you are a Optics laboratory that would like more information on these Optics projects, please visit our registration page or call toll us free 1-855-377-6821.

Below are our 50 most recent Optics laboratory test requests. Please log in to see more.

Test Request 17-01686

Optics

Independent, Third-Party Laboratory needed for LED lighting performance comparison study for a couple of LED lighting products in order to make a quality decision between two competing suppliers. The testing required is a Photometric report simple integrating sphere test giving metrics such as total lumen output, spectrum, CCT, lumens per watt etc would suffice. 4 reports in total.

Closed

Test Request 17-01666

Optics

Materials laboratory needed for measurements on an anti-reflection coating on both external surfaces of a cemented doublet measured. The diameter of the doublet is 110mm, and the focal length 500m. The reflectance of the coatings is specified as < 0.2% at 632.8nm and normal incidence, whereas we measure > 0.4%. I am looking for measurements from an independent laboratory to convince the vendor to take the lens back.

Closed

Test Request 17-01020

Optics

Medical device laboratory needed for ISO testing of blue light and UV ray blocking optical lenses including ISO 8980-3, Ophthalmic Optics - Uncut Finished Spectacle Lenses - Part 3 Transmittance Specification and Test Methods.

ISO 14889, Ophthalmic Optics - Spectacle Lenses - Fundamental Requirements for Uncut Finished Lenses.

Closed

Test Request 17-00979

Optics

Electrical laboratory needed for comparison study of two light products for distribution of light, light intensity, and energy output.

Closed

Test Request 17-00847

Optics

Materials laboratory needed for determination of optical transmission characteristics of red plastic lens resin used in laser receiver products. The optical transmission characteristics are important for this part so that it can filter sunlight while passing near IR laser wavelengths.

The study involves determination of the total transmissibility vs. wavelength for various red plastic lens samples. The wavelength range of interest is roughly 250-1250 nanometers (in 1 nm increments) at a minimum. A report shall be provided that includes the following at a minimum, test lab name, test date, test equipment used, test specimen condition, and graphical results of the optical transmission range, minimally including 250-1250 nm in 1 nm increments, for each sample

Closed

Test Request 17-00712

Optics

LONG-TERM TESTING Lighting manufacturer needs physical laboratory for SAE and NFPA certification testing of LED lighting products to SAE J595, SAE J845, California Title 13, NFPA 1901-2009, KKK-A-1822F

Closed

Test Request 17-00588

Optics

Materials laboratory needed for ANSI Testing of LED Smart Film products to meet welding filter requirements of ANSI Z87.1-2015 table 6, American National Standard for Occupational and Educational Personal Eye and Face Protection Devices

Closed

Test Request 17-00435

Optics

Medical Device (Optics) laboratory needed for analytical chemistry testing of potential contaminants in a product coating liquid via NMR and FTIR. GC/MS may also be necessary for analysis.

Closed

Test Request 17-00359

Optics

LONG-TERM TESTING Manufacturer needs Aerospace laboratory for FAA Testing of air field lighting transformers.

Closed

Test Request 17-00273

Optics

Electrical laboratory needed for SAE compliance testing of optical warning devices used on authorized emergency, maintenance, and service vehicles to SAE J845 Class 1 . Recommended practice providing design guidelines, test procedures, and performance requirements for 360 degree optical warning devices and selective coverage defined as any light that provides greater coverage then 40 degrees left-to-right but less than 360 degrees. Intended for authorized emergency, maintenance and service vehicles. Lighting tested from 5 degrees upward to 5 degrees downward.

Closed

Test Request 17-00199

Optics

Optical filter laboratory needed for transmissivity from UV testing through the visible spectrum of three filter glasses with the assumption two are band pass filters--the first centered around 430nm, the second around 365nm, and the third is short pass.

Closed

Test Request 17-00019

Optics

Accredited Photometry laboratory needed for testing functional and climatic tests on retroreflectors.

Closed

Submit Optics Testing Requests for Optics testing and Optics Scientific Research