NEED LABORATORIES OR LAB SUPPLIERS?

ARE YOU A LABORATORY OR LAB SUPPLIER?

SUPPORT

Questions / Comments?
Call 1-855-377-6821or

Incoming Industrial Laboratory Testing and Scientific Research Requests

Contract Laboratory has received the following incoming Laboratory Testing and Scientific Research Requests which need to be fulfilled! These Laboratory Test Requests are received from a variety of sources ranging from start-up companies to large, multinational Fortune 500 corporations, international organizations, well-respected universities and government agencies that are actively seeking Labs to perform their Laboratory Testing and Scientific Research. If you need a Laboratory, please Submit a Laboratory Testing Request. If you need assistance or have questions email us or call toll free 1-855-377-6821.

19-00509

Industrial

Industrial Laboratory needed for ASHRAE HVAC air registers testing for home HVAC systems for air flow, static pressure drop and throw, sound testing for a number of different sizes of our products

Submit Response

19-00487

Industrial

USA Automotive Laboratory needed for certification of motor vehicle parts to specifically adult car seat safety to FMVSS.

Submit Response

19-00477

Industrial

LEGAL Industrial Environmental Microbiology laboratory needed for settled dust testing for water soluble proteolytic enzymes substilins. A reputable laboratory has identified B. substilin in a dust sample collected in an HVAC air duct, so we would like to know if the settled dust contains water soluble proteolytic enzymes substilins.

Closed

19-00455

Industrial

START-UP Air filtration company needs Laboratory for AHAM AC1 CADR Dust challenge testing

Closed

19-00454

Industrial

Packaging Laboratory needed for OTR, WVTR and MVTR testing in related to packaging (sachet, foil)

Closed

19-00440

Industrial

Industrial Laboratory needed for carbide tip saw blade wear testing on common particle board vs. a particle board that was pressed.

Closed

19-00433

Industrial

Canada Research Facility needed for studying the staining profile of smoke residue on glass substrates.

Submit Response

19-00430

Industrial

URGENT Accredited Materials Laboratory needed for bonding suitability testing of a glue product in an art glass and metal sculpture. The sculpture is of a series of glass balloons of 1.2 kg It will be connected to the wall using a metal fixture specifically manufatured for glass. Glass glue product will be used for the bonding the metal fixing to the glass. The client needs it to be proven that the proposed glue product is suitable for connecting the balloon to the metal tree fixings. This must be tested and signed off by an accredited, independent lab. 2 A glue product will be used for glueing glass balloons sheet glass using a UV glue. This needs to be tested and signed off by an accredited, independent lab. I am based in Ireland but can ship to USA. The testing is urgent.

Submit Response

19-00418

Industrial

Papermill needs Europe Food Laboratory for starch type identification from samples (wheat, potato, corn, tapioca)

Submit Response

19-00415

Industrial

Materials Laboratory needed for SASO certification testing of 3 adhesives: 1. PURLIN TAPE 2 X 30.YRD 2. EPDM FOAM ONE-SIDE ADHESSIVE TAPE (Various width) 3MM / 4MM THICK ROLL SIZE : 7.5MTR /ROLL 3. SELF ADHESIVE TAPE (CLEAR TAPE)

Submit Response

19-00404

Industrial

Nano-Pharmaceutical Company needs Laboratory for containment performance testing for its contained equipment such as isolators. Please answer the following questions: - Do test procedures differ based on different APIs? - Which APIs can you analysis? Do you already have a data base? - Do you supply the filters and cassettes

Submit Response

19-00403

Industrial

Industrial Laboratory needed for rockwool pipe testing to be in compliance to enter the USA market

Submit Response

19-00399

Industrial

Consumer Products Laboratory needed for ASTM testing of 6 colors of artists oil paints tested to be in compliance with ASTM D4302 Standard Specification for Artists? Oil, Resin-Oil, and Alkyd Paints

Submit Response

19-00386

Industrial

Small Construction Co needs Construction Materials Lab for evaluation of driveway glue tile adhesive used with waterproofing that has been comedrummy and not bonded with the waterproof.

Submit Response

19-00381

Industrial

Third-Party Laboratory needed for ISO testing on sports protective padding to ISO 10819:2013. Mechanical vibration and shock Hand-arm vibration Measurement and evaluation of the vibration transmissibility of gloves at the palm of the hand

Submit Response

19-00374

Industrial

Packaging Laboratory needed for UN HAZMAT testing of corrugated packaging to issue UN certification.

Submit Response

19-00371

Industrial

Biopharmaceutical needs FDA GMP Packaging Laboratory for Container Closure Integrity test (CCIT) with validated method.The package integrity verification will be performed on the final drug product as release and stability test.The drug product, is water based, supplied as a liquid in 15 ml glass vials stored at 5°C under nitrogen.

Submit Response

19-00364

Industrial

Oil Laboratory needed for Discous Oil Analysis of Machinery Fundamentals lubrication.

Submit Response

19-00363

Industrial

Wallpaper Producer needs Industrial Laboratory for fire testing according to the EUROCLASS system (Reaction to fire in accordance with EN 13501-1 - in the UK the rule is called BS EN 13501-1). Please provide a quote

Submit Response

19-00362

Industrial

Nanotechnology Laboratory needed for nanoparticle coating solutions testing based on metal dioxide Nano particles used for coating of SS steel.we have 2 needs .1.. Establish a laboratory and and a procedure of making the nanoparticle SOL. We need to know how to control the process to obtain the specification of the product, as well as we do not have any equipment to check the final product.2 to act as quality control of the final product , and to act as a adviser regarding how to deal with product / process variations as well as assist in feather development

Submit Response

19-00359

Industrial

Technology Laboratory needed for Industrial Robotics Application Testing in Multiple areas: System reliability Accuracy Test Repeatability Functional testing

Submit Response

19-00358

Industrial

Packaging Laboratory needed for ASTM testing of pop top bottle to ASTM D3475 Standard Classification of Child-Resistant Packages

Submit Response

19-00353

Industrial

Materials Laboratory needed for NRC testing and fire rating of acoustical polyester fiber sheets.

Submit Response

19-00344

Industrial

Manufacturer needs Construction Materials Laboratory for ASTM testing on curing compounds for concrete to ASTM C309 ( A standard test method for water loss through liquid membrane-forming curing compounds for concrete). We would require this testing to be done on a steel trowel surface rather than a more porous surface like a broom finish. Steel trowel finishes result in a harder, tighter surface that reduces moisture loss, this is the type of surface our client will be using our curing compound product on. Please respond with the fee for the test and when would you be able to do the test?

Submit Response

19-00342

Industrial

Materials Laboratory needed for textile testing for far infrared reflection

Submit Response

19-00336

Industrial

Materials Laboratory needed for ANSI ballistic testing for monolitic glass to ANSI Z26.1 lab tests applied to six different references of ballistic level ( IB, IIB, IIIC, IVC, VA y VC ) :ANSI Z26 TEST 30 Light StabilityANSI Z26 TEST 31 Luminous TransmittanceANSI Z26 TEST 29 Impact (Ball drop)ANSI Z26 TEST 32 Optical Deviation and Visibility Distortion Additionally one (1) ANSI Z26 TEST 18 Abrasion Resistance test for 1 mm monolitic glass.Thanks in advance for your prompt response and collaboration

Submit Response

19-00334

Industrial

Large Food Company needs Europe Independent Industrial Laboratory for ISBN certificate, for nitrogen and CO2 analysis used in the food industry

Submit Response

19-00331

Industrial

Consumer Products Laboratory needed for microwave safety testing for molded fiber food service container packaging.

Submit Response

19-00300

Industrial

Packaging Laboratory needed for Child Resistant Packaging testing for the cannabis industry to get CRP certification.

Submit Response

19-00291

Industrial

Vape Company needs Product Safety Laboratory needed for e-vape packaging testing to comply to canada CCCR2001 Canada's Consumer Chemicals and Containers Regulations

Submit Response

19-00276

Industrial

Mining Company needs Laboratory for failure analysis investigation of seat belt failure at one of their mines which caused the operator to fall out of the cab of his loader. If I send this seat belt to you would you be able to examine and test it to determine why or how this happened?

Closed

19-00270

Industrial

Supply Company needs Packaging Laboratory for ISTA Package Certification Testing to ISTA-3A General Simulation Performance Tests

Submit Response

19-00264

Industrial

USA Packaging Laboratory needed for Medication Child Resistant CR paperboard cartons testing in accordance with the USA and European Child Resistant Packaging Certification

Seeking lab for CR certification.

Submit Response

19-00262

Industrial

US Company needs exporting adhesive tapes to Saudi Arabia needs ISO 17025 Accredited Laboratory with SASO certification to carry out these two ASTM testing: ASTM D 5486- Standard Specification for Pressure-Sensitive Tape for Packaging, Box Closure, and Sealing ASTM D 6123- Standard Specification for Pressure-Sensitive Tape for Light-Duty Packaging and General Purpose Masking

Do you carry out these tests and are you accredited ISO 17025?

We would need a quote for our request.

Thank you Best regards

Submit Response

19-00260

Industrial

Independent Packaging Laboratory needed for Oxygen Transmission Rate OTR Testing in laminated foil pouch.

Submit Response

19-00256

Industrial

Nanotechnology laboratory needed for synthesis and characterization of new thermoset nanocomposites based on polymer and montmorillonite clay to be used for new applications. The aim of this work is the synthesis and characterization of thermoset nanocomposite based on poly (e-caprolactone) and Montmorillonite clay which present a new class of biodegradable materials allowing them to be an environment-friendly alternative .

Characterization techniques required : ? NMR Analysis ? FTIR Analysis ? Thermogravimetric Analysis (TGA, DTA) ? Differential Scanning Calorimetry (DSC) ? X-Ray Diffraction ? Transmission Electron Microscopy (TEM) ? Atomic Force Microscopy (AFM)

Submit Response

19-00255

Industrial

Independent Laboratory needed for failure analysis of Car Air Freshener Gel that is experiencing a dispensing problem

Submit Response

19-00246

Industrial

Independent Laboratory needed for TXL and GXL cable testing to SAE J1128 Low Voltage Primary Cable

Submit Response

19-00236

Industrial

India Automotive Laboratory needed for AIS Anti theft testing of keyset to AIS 075 Approval of Vehicles with regards to their protection against unauthorised use-four wheeled vehicles

Submit Response

19-00232

Industrial

Food Laboratory needed for testing of a vegan coating after spray coating 4 food compounds with the coating.

Submit Response

19-00229

Industrial

Pharmaceutical Laboratory needed for Complete Excipients and Packaging Material testing as per USP/NF, Ph.Eur. and Vendor In-House Method including elemental impurity and microbial testing.

Submit Response

19-00225

Industrial

Performance Laboratory needed for filter testing as per KEBS Standards

Submit Response

19-00224

Industrial

Large Packaging Corporation needs Materials Laboratory for testing to the following test methods standards: EN12068, ASTM E96, ASTM D1000/D257, ASTM G21 and IRAM 14546-3.

Closed

19-00211

Industrial

Experienced Materials Laboratory needed for analysis of novel carbon powder samples containing fluorine surface functional groups and having its F content analyzed. Techniques of interest include IC, Potentiometric titration, FTIR, XPS etc. The material is novel

Laboratory must be familiar with this combination of material and analysis. Attaching a quote or order form with a response is also appreciated.

Submit Response

19-00210

Industrial

Consumer Products Laboratory needed for assistance on development of testing for claims substantiation of a garment that could protect against lower extremity injuries.

Submit Response

19-00201

Industrial

Materials Laboratory needed for ASTM E595 testing for encapsulation resins and conformal coatings. Please provide one set price per product and another for multiple products tested together?Can you please give me prices for 1, 5 or 10 resins for example?

Submit Response

19-00195

Industrial

Packaging Laboratory needed for ASTM packaging transportation testing for medical product which comply to ASTM D4169 Standard Practice for Performance Testing of Shipping Containers and Systems

Submit Response

19-00189

Industrial

MULTIPLE LABORATORIES NEEDED Research Center needs Laboratory for some TGA and DSC testing on some shared samples as part of interlaboratory tests of proficiency.

Submit Response

19-00175

Industrial

Materials Laboratory needed for lifetime testing of a new adhesive coating we are planning on using on an aerospace and defense application.

Submit Response

19-00174

Industrial

FUNDING APPROVED Preclinical CRO needed for in vivo acute toxicity and product safety study of pharmaceutical drug coating using 5 different medical devices and 2 different non-drug coating controls. This study . which is a modification of Rabbit intramuscular implant study (~ISO 10993-6) - 5 separate PVC-based devices with different coatings - 2 pieces per device - 3 time points (6hr, 24hr, 1 week)

Submit Response

19-00168

Industrial

USA Physical Laboratory needed for ANSI flat glass and tempered glass testing including:

Ball Drop test, Edge stress, surface stress, laminated glass clarity test, Edge condition, Printing and Obscuration Band test (Frit), and any other ANSI and FMVSS tests required. And similar tests for Tempered glass as well.

Submit Response

19-00167

Industrial

Third-Party Laboratory needed for lab analysis of depth filters (filter media) which contains resin according to 21CFR 177.2260 Filters, resin-bonded with: water, hexane, acetic acid, 8% ethanol and 50% ethanol. Thanks

Submit Response

19-00149

Industrial

LONG-TERM TESTING PARTNERSHIP Analytical Instrument Manufacturer needs Food Laboratory to support them on an evaluation of the testing various agriculture, food, and potentially cannabis applications using their analytical instruments to show proof of concept

Submit Response

19-00138

Industrial

Large Mechanical Contracting Company needs Industrial Hygiene Laboratory for combustible dust analysis at a company's facility

Closed

19-00137

Industrial

Company would like to speak to Laboratory on scheduling soda loss testing on a pulp mill washer line.

Submit Response

19-00135

Industrial

Materials Laboratory needed for ASME testing of plastic bags to ASME D6400 Standard Specification for Labeling of Plastics Designed to be Aerobically Composted in Municipal or Industrial Facilities

Submit Response

19-00134

Industrial

Performance Laboratory needed for ANSI certification testing of Hi-Vis safety vest to ANSI/ISEA 107. Our target is ANSI Class 2 Type R. If you are able to run these tests please let me know what it would cost and what is provided at the end of the test

Submit Response

19-00127

Industrial

PRODUCT DEVELOPMENT Research and Development Laboratory needed for caffeine inhaler in the laboratory.

Submit Response

19-00116

Industrial

USA Physical Laboratory for Vacuum Seal Test and Torque testing to ensure dietary supplement product are not leaking.

Submit Response

19-00109

Industrial

Packaging Company needs Microbiology Laboratory for testing antibacterial cloth according to REACH 155 SVHC HEAVY METAL IN PACKAGING ANTIBACTERIA JIS L 1902-2008

There will be 2 types, I believe the only difference is the colour, but we will need to test both just in case.

Please can you confirm the lead time, price and how many samples you will need for the tests?

Thank you .

Closed

19-00106

Industrial

Packaging Laboratory needed for ASTM distribution and environmental testing of cartons and blister packs of liquid-filled product to ASTM Test Standards ASTM D4169 DC13 ASTM G155 60C/90%RH testing -25C testing

Closed

19-00102

Industrial

Medical Device Safety Performance Laboratory needed for EN Spectral transmittance in the ultraviolet for phototherapy masks using the European Standard EN 170 Personal eye-protection - Ultraviolet filters - Transmittance requirements and recommended use

Closed

19-00080

Industrial

Reputable USA Industrial Testing Facility needed to measure activated carbon filter media efficiency according to Ashrae 145-1

Closed

19-00076

Industrial

FDA GMP Packaging Laboratory needed for USP testing of pharmaceutical packaging material as LDPE, HDPE and different blister like PVC,PVDC, Aclar and Alu/Alu as per USP general chapter 661,662 and 671

Closed

19-00074

Industrial

Large Electrical Company needs Laboratory for glass gems composition testing

Closed

19-00061

Industrial

Polymer Laboratory needed for oxygen and moisture barrier testing on plastic bags.

Closed

19-00051

Industrial

FDA GMP Laboratory needed for ISO VOC, particulate, CO, CO2 and Ozone testing for respiratory monitoring device (dry gas pathway).

Closed

19-00045

Industrial

Large Cleaning Products Company needed for 30-day vibrio challenge testing after treatment with proprietary products. Test will contain at least 4 treatments. Need multiple replicates for each treatment.

Closed

19-00043

Industrial

Third-Party Laboratory needed for environmental simulation and packaging testing of new foam composite packaging materials made from wood and nanocellulose. drop test, humidity (climate) test to measure the amount of moisture adsorption using the humidity chambers and the compression test. Please give us a cost estimation of these tests also how long time it takes for each test? What are the sample size and quantity requirements for the drop test, compression test and the climate test?

Closed

19-00038

Industrial

Large Pharmaceutical Company needs ISO 17025 Packaging Laboratory for ASTM distribution/transit testing for pharmaceutical products to the following standards: ASTM D4169, ASTM D4728, ASTM D5276, ASTM D6653, ASTM D999

Closed

19-00033

Industrial

Materials Laboratory needed for ASTM testing of coating material in accordance to ASTM C1305 Standard Test Method for Crack Bridging Ability of Liquid-Applied Waterproofing Membrane

Closed

19-00023

Industrial

Safety Laboratory needed for safety apparel testing as per ANSI/ ISEA 107 Type R Class 2 American National Standard for High-Visibility Safety Apparel and Accessories testing requirement

Closed

19-00020

Industrial

Laboratory needed for welding helmet testing for compliance to the ANSI and CSA standards and issue a certificate of compliance with test report.

Closed

19-00008

Industrial

Microbiology Laboratory needed for DIN microbial barrier testing of packaging to (DIN58953 - 6 Sterilization; sterile supply; sterilization paper for bags and tube packings; test) for my sample meant for packaging.

QUESTIONS: Please answer the following questions: How much will it cost? How much samples should I send for testing? What will be the turn around time for the results?

Closed

18-01928

Industrial

Materials Laboratory needed for Nitrile Glove Testing to Chemotherapy Drugs and Concentration ( Tested for Resistance to Permeation by Chemotherapy Drugs as per ASTM D6979-05 Standard Test Method for Polyurethane Raw Materials: Determination of Basicity in Polyols, Expressed as Percent Nitrogen

Closed

18-01925

Industrial

Green company needs laboratory for all required testing on eco-friendly shower filter for sale to the US including whether it is compatible with related necessary tests and certificates or not ? , Please be so kind and send us quote ASAP.

Closed

18-01923

Industrial

Large Chemical Company needs Clinical Research Laboratory for the following dematological studies: Patch Testing and Repeat Insult Patch Testing RIPT.

Closed

18-01910

Industrial

Polymer Laboratory needed for semicarbazide testing on polypropylene bottle caps.

Closed

18-01901

Industrial

Physical Laboratory needed for ASTM testing to ASTM E756-05 Standard Test Method for Measuring Vibration-Damping Properties of Materials

Test conditions to be specified at the frequency of 200Hz at the following range(10, 15, 20, 25 °C) Specimen is ready for your test.

Closed

18-01895

Industrial

Industrial Laboratory needed for the following IEC wire assembly testing: wire pull testing, hi-pot testing of crimped wire assemblies in passenger rail car manufacturing for compliance to IEC 60523 Direct-current potentiometers

Closed

18-01891

Industrial

Laboratory needed for performance testing of road traffic noise reducing devices to standard: EN 1794 Road traffic noise reducing devices. Non-acoustic performance. Mechanical performance and stability requirements

Closed

18-01889

Industrial

Materials Laboratory needed for ASTM Testing of coating to ASTM F519 Standard Test Method for Mechanical Hydrogen Embrittlement Evaluation of Plating/Coating Processes and Service Environments

Closed

18-01878

Industrial

ISO 17025 Forensics Laboratory needed for failure investigation analysis of PET preforms. One PET preform has a grey shade and another PET preforms has a pink shade. Both preforms made from the same materials. Pink preforms overheated at the temperature that grey preforms not. In this case we think that investigation of carbon content in both preforms will help us to find the cause of problem.

Closed

18-01876

Industrial

USA Microbiology Laboratory needed for Antibacterial Resistance Testing of door handle surface in compliance with the US requirements.

Closed

18-01875

Industrial

Large Corporation needs Laboratory for transmittance and anti-fog verification testing of goggle lens' used in clean rooms.

Closed

18-01865

Industrial

Large Pharmaceutical Company needs Packaging Laboratory for testing 3 different EPS foam containers in compliance to ISTA 7E. We currently ship Pharmacy goods across 4 provinces within 2-8°C and wish to provide updated qualification documentation for our packaging. We are located in Vancouver BC

Closed

18-01862

Industrial

Laboratory needed for filter media collection efficiency by using PAO. DOP is currently used for Collection Efficiency testing to using PAO and firm wishes to compare or switch to revised method ASTM D 2986-91 showing a different substance than DOP

Closed

18-01844

Industrial

Materials Laboratory needed for ASTM peel off performance testing of reduced graphene oxide rGO coated textiles with adhesive tapes. The process for common peel off tests are 90, 180, circular and T-shape test standards for common adhesive materials Flexible-rigid, Flexible-Flexible contact which ever is suitable according to ASTM standards for Textile substrates such as woven, knitted fabrics.

Closed

18-01843

Industrial

Large Industrial Manufacturing Company needs Laboratory for SAE Air Dryer Testing to SAE J2384 Air Dryer Test Procedure, This Standard defines the Test Procedures for desiccant Air Dryers used in vehicles with compressed air systems

Submit Response

18-01840

Industrial

LONG-TERM TESTING Laboratory needed for verification of the contents of 2-3 gas samples/ a week (in 500-1000 mL Tedlar bags) via gas chromatography. The gas is created in a hydrogen reformer that creates a H2 rich gas from oxisteam reformation of methanol. The reformat gas that we produce consists of the following: H2 (37%) N2 (45%) CO (6%) CO2 (12%)

We would like to have gas samples tested (via gas chromatography) by an independent lab so as to verify results.

Closed

18-01832

Industrial

PROCESS DEVELOPMENT Polymer Laboratory needed for working on a project that wants to create an optimized process of polyurethane injection, that´s including the simulation using finite elements, but we are stopped in the characterization of the foam for the input data in the software.

Closed

18-01823

Industrial

Materials Laboratory needed for adhesives comparison study testing for peel adhesion, temperature range for double coated tape for corrugated application. Comparison of various tapes provided by our supplier.Thickness (not including liner), adhesive thickness, carrier, liner thickness, peel adhesion, temp range to current customers specifications.

Closed

18-01822

Industrial

Medical Device Company needs Performance Laboratory for ISO Testing for pressure drop and moisture loss and salt testing on heat and humidity exchangers(HME) in order to obtain product performance data according to standards: ISO 9360 and ISO 23328-1:2003

Closed

18-01811

Industrial

Laboratory needed that is capable of performing chemical tests for the pigment Carbon Black Powder, according to Brazilian Ordinances RDC 17 (page 20) and RDC 52 (Item 2).

Closed

18-01808

Industrial

Manufacturer needs Third-Party CPSC Consumer Products Laboratory for General Certificates of Conformity (GCC) testing for 3 different types of imported mirrors

Closed

18-01803

Industrial

Pharmaceutical Packaging Laboratory needed for USP MVTR (Moisture vapor transmission rate) of Blister packs as per the USP 671.

Closed

18-01802

Industrial

Industrial Laboratory needed for propellant testing to industry standard qualifications and certifications including: 1. Thermal stability and JANNAF thermal stability test results 2.Card gap data 3. Impact test data 4. Detonation test results 5. Unconfined burning test results 6. Adiabatic compression test results 7. Critical diameter test data 8. Flashpoint test results 750C (propane flame) 9. Minimum pressure for vapor phase ignition test results 10. Electrostatics tests results (1 gf and 12.5 Joules at 5 kV)

Closed

18-01801

Industrial

Safety Lighting Manufacturer needs component tested for multiple temperature and vibration conditions

Closed

18-01798

Industrial

Materials Laboratory needed for OECD testing of Automotive Sealer Coating in compliance to Transport of UN Dangerous Goods including the following testing

1. Test of chemical products no.404 Acute dermal Irritation / corrosion 2002 guideline of the OECD 2. Determination of the PH 3. Assess the acid or alkaline reserve 4. Test for solid substances that enter easily in combustion (igniting the substance and calculating the duration of the combustion according to page 383 of the manual Recommendations regarding the TRANSPORT OF UN DANGEROUS GOODS

Closed

18-01793

Industrial

Automotive Laboratory needed for DIN testing of polycarbonate sheet for determining The Optical Distortion And Refractive Power Of Safety Glazing Material For Road Vehicles to DIN 52305:1995 Testing material - polycarbonate sheet

Closed

18-01781

Industrial

Food Company needs Microbiology Laboratory for anaerobic biodegradable testing on food contact plastic container

Closed

18-01776

Industrial

Asia Packaging Company needs Packaging Laboratory to provide outgas testing, ionic contamination, FTIR testing

Closed

18-01762

Industrial

LONG-TERM TESTING US Plastics Laboratory needed for quarterly ASTM testing of thermoformed plastic food packaging with biodegradable additives for PP and PET to standard ASTM D5511-11 as required by our customers.

1.One treated PP sample - 19 gms (2-compartment tray) 2.One treated PET sample ? 10 gms (12oz PET cup )

Kindly send us your quotation, lead time and other inclusions/information needed. We would at least require a report every 3 months, if possible and a Certificate or Letter

Closed

18-01759

Industrial

Laboratory needed to test flake graphite concentrate for carbon content levels, particle size distribution, bulk and tap density, thermo gravimetric analysis and an exhaustive list of the impurities in the graphite.

Closed

18-01758

Industrial

PRODUCT DEVELOPMENT Materials Laboratory needed for testing to certify a Plastic Child safety device to sell on Amazon. The device has already passed the initial pass on the prototype phase. Will need the first few hundred tested from a new mold manufactured in the US. I think 1 of every thousand to comply And to comply with Amazon.

Submit Response

18-01752

Industrial

Electrical Laboratory needed for modular wiring products tested and certificated to BS8488 Prefabricated wiring systems intended for permanent connection in fixed installations..

Closed

18-01749

Industrial

Pharmaceutical Company needs Packaging Laboratory for FDA and MHRA 16CFR1700.20 testing to some HDPE bottles and caps.

This products are a Pharmaceutical drug product (Rx) to be commercialized in USA. The child resistant test report will be reviewed by FDA in our application.  Our package is : PUSH, DOWN AND TURN - CLOSE TIGHTLY.  The packages will be used for solid dosage form.

Closed

18-01739

Industrial

Fortune 500 Company needs Packaging Laboratory for Mil-Spec package testing for bags Mil-spec 2073 appendix g Standard Practice for Military Packaging.

Closed

18-01737

Industrial

Optical Laboratory needed to determine the transmission properties of glass to determine it's use in solar panels

Closed

18-01724

Industrial

AIHA Certified Laboratory needed for analysis of 3 sorbent tubes of two gaseous samples plus a blank for piperidine via OSHA CSI.

Closed

18-01722

Industrial

Third-Party Mechanical Laboratory needed for certification testing on 3 different Cables Lugs ( 120 Sq.mm , 240 Sq.mm, 300 Sq.mm).:

Closed

18-01712

Industrial

Large Motorcycle Company needs test facility who has the capabilities to perform testing on protective gear for hi-visibility. Garments will be tested and certified (if applicable) to IS 15809: 2008 and AS/NZS 4062.1: 2011 (+A1).

Closed

18-01706

Industrial

Tree Nurseries needs United Kingdom Agriculture Laboratory for air and surface pesticide residues (dust/droplets/vapours) are on the inside of the equipment used to apply the range of plant protection products including equipment attached to a tractor - boom sprayer, granular applicator and orchard sprayer. We would like to find out if any pesticide are getting to the inside of the enclosed tractor cab. To achieve this we would like to carry air testing and possibly cabs surface testing within the cab during pesticide applications using methodology as/or similar to what's outlined in this link: http://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs94-2.pdf (surface exposure section). Using fluorescein as a 'visual' is unlikely to work given the potential aerosol size BUT possible using analytical equipment (maybe using a different tracer).

Pleas

Closed

18-01704

Industrial

Packaging Laboratory needed for burst testing for a 20L plastic container with UN rating 3H1/Y1.8/300 to evaluate if they have degraded over repeat usage. During our process we pressurize the containers and have noticed discoloration but so far none have failed. Our pressure holds at no more than 150kpa during the process but would like to know what capacity they can hold.

Closed

18-01698

Industrial

Coatings Company needs Polymer Laboratory for ASTM testing on polyurethane based membrane to ASTM C836 Standard Specification for High Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course Please send me quotation and the sample requirements. Thank you,

Closed

18-01695

Industrial

Electrical Laboratory needed for SAE certification and testing of single conductor wires to SAE J1128 Low Voltage Primary Cable

Closed

18-01689

Industrial

Materials Laboratory needed for epoxy phenolic coating testing according to EI 1541 (Standard for aviation fuel coating)

Submit Response

18-01684

Industrial

Forensics Laboratory needed for Forensic Ink Date Testing for a one page document believed to be 19 years old. Would interested in professional opinion general age or a window of time that you can use in negotiations and/or in an official capacity. Please contact requester with questions.

Closed

18-01681

Industrial

Advanced Materials Company needs Materials Laboratory for ASTM testing of metal clad fibers to ASTM E595 Standard Test Method for Total Mass Loss and Collected Volatile Condensable Materials from Outgassing in a Vacuum Environmentfor TML (Total Mass Loss) and CVCM (Collected Volatile Condensable Materials) data.

Closed

18-01658

Industrial

California Materials Laboratory needed for confirmation testing on cut rubber ties. The original test report was done in Australia and can be provided for reference.

Closed

18-01651

Industrial

India Industrial Laboratory needed for for quality control certificate of analysis for PET flakes made from pet crushing and washing business prior to selling to buyer

Closed

18-01645

Industrial

LONG-TERM TESTING Glass corporation needs a partnership with a large international laboratory for testing their glass used in the transportation sector. Once we receive company's interest, we can attach the testing matrix

Closed

18-01637

Industrial

Large Chemical Company needs Germany Polymer Laboratory for Investigation of Polymer Materials in view of material characterization according to USP <661> and Reference EPA method.

Reference method is USP , <661>: Container plastic.

- Analysis for Metals

Closed

18-01632

Industrial

PRODUCT DEVELOPMENT USA Biotechnology Laboratory needed for formulation of a biological/enzyme based RV holding tank deodorizer

Closed

18-01624

Industrial

Automotive Company needs Industrial Microbiology Laboratory needed for microbiological study in which the reproduction is determined on 6 different bacteria. The research study is similiar to ISO 22196 Measurement of antibacterial activity on plastics and other non-porous surfaces

Closed

18-01608

Industrial

USA Third party Industrial Laboratory needed for ASME Testing of the quality of spiral wound gasket in accordance with ASME B16.20 Metallic Gaskets for Pipe Flanges

If so, please send me a quotation and hope to receive today.

Closed

18-01602

Industrial

Automotive Laboratory needed for GMW testing of labels to against the GM spec GMW 14573 Global Performance Requirements for Labels

Closed

18-01591

Industrial

USA Product Safety Laboratory needed for multiple tests on electric polyester heating element including:

CSA, NEC/CEC, NFPA 70,CSA CEC 22.1 IEEE 215 or IEC 62395-1, water resistance test integral components resistance to water elevated temperature exposure to dielectric test deformation test

94 V0 flammability, VW1 for AC wiring hi Pot per 60950 60950-22 creepage, clearance,flammability and insulation for basic isolation UL water test submersion wire pullout test per UL 486 GR-487 R3-32 Chemical resistance cabinet components of polymeric materials R3-36 flammability resistance R3-39 fungus resistance R3-260 salt fog resistance R3-261 all cabinet components shall be resistant to corrosion OSP battery drop test OSP TP000113-TP-01-AA Heater assy. drop test per OSP TP000114-TP-AA gr-487-CORE. Resistant to Potas

Closed

18-01584

Industrial

Europe Materials Laboratory needed for penetrability testing for rubber stoppers according to European Pharmacopoeia

Closed

18-01570

Industrial

Air Purification Company needs Industry Laboratory for ASHRAE H2S removal efficiency to ASHRAE 145.2 Laboratory Test Method for Assessing the Performance of Gas-Phase Air-Cleaning Systems: Air-Cleaning Devices for .

Closed

18-01562

Industrial

Automotive Laboratory needed for automotive adhesive testing to GMW14573 Label specification testing. Automotive adhesive label testing.

Closed

18-01553

Industrial

Pharmaceutical Third-Party Laboratory needed to conduct on-site surrogate testing for containment equipment according to ISPE SMEPAC method guidelines for particulate containment performance.

Closed

18-01551

Industrial

Materials Laboratory needed for ASTM testing of Coatings to ASTM E-1795 Standard Specification for Non-Reinforced Liquid Coating Encapsulation Products for Leaded Paint in Buildings

Closed

18-01526

Industrial

Laboratory needed for ASTM testing on fiberglass / Glassfiber reinforced plastic FRP/GRP pipes needed for oil and gas project 1. Full regression test according to ASTM D2992:1996-Procedure B) 2. 1000 hours survival tests according to ASTM D1598

Closed

18-01520

Industrial

Pharmaceutical Company needs IAS Packaging Laboratory needed for US 16 CFR 1700.20 Testing procedure for special packaging.

Closed

18-01512

Industrial

Polymer Laboratory needed for % ash testing for in HDPE bottles.

Closed

18-01497

Industrial

Europe Materials Laboratory needed for waterproofing testing as per EN 13948: 2007 Flexible sheets for waterproofing. Bitumen, plastic and rubber sheets for roof waterproofing. Determination of resistance to root penetration.. Please provide an estimate on cost.

Closed

18-01496

Industrial

PRODUCT DEVELOPMENT Packaging Laboratory needed for certification testing of several new child resistant products. Please provide a quote for the services .Thank you for your soonest reply. .

Closed

18-01495

Industrial

NEW PRODUCT DEVELOPMENT Microbiology Laboratory needed for Research and Development (R&D) assessment of a new Rapid Bacterial Enumeration and Identification System Prototype with comparison to existing .Standard Plate Count bacteria study methods. and become a true breakthrough in the field. We would like to work with you in the assessment of this technology, testing the prototype.

Closed

18-01469

Industrial

Performance Laboratory needed for : protective glove testing as per the following standards: -EN388:2016 -ISO13997 -EN420

Closed

18-01466

Industrial

URGENT urgently needs Laboratory for the following tests

1. ASTM F2992-15 - TDM for Cut resistance. 2. ASTM D3389-10 and D3884-09 for Abrasion 3. EN 388:2003 for Puncture (2016 Update) 4. For Impact protection since there is no set standard under the URGENT ANSI/ISEA 105 2016, can we request and EN 388 Impact test? Goat shin gloves with aramid Lining and TPR (Leather Work Gloves)

We need quote ASAP. We have samples on hand and would like to proceed with testing.

Jelena Ozgur Sales and Marketing Manager www.keruigroup.com 832 506 7728 6303 N Sam Houston Pkwy W Houston TX 77086

Closed

18-01457

Industrial

Packaging Laboratory needed for ASTM Testing of a 15 ml jar with a CR cap to ASTM Type 1 re closable packaging continuous thread

Closed

18-01451

Industrial

Cosmetics Company needs Packaging Laboratory for failure analysis for the cause of leakage from our product packed in bottles with caps to determine if the caps not the proper fit for the bottles or the caps has not been sealed properly?

Closed

18-01429

Industrial

Additive manufacturing researcher needs Metallurgical Laboratory for elemental analysis of metal powders before printing and bulk materials after printing. We would also like particle size and shape analysis, O-H-N analysis.

Closed

18-01423

Industrial

Large Materials Laboratory needed for multiple tests on automotive coating including: EU REACH Phys. Chem properties OECD Tests Auto flammability Biodegradation in water: screening tests Boiling point Flash point Melting point / freezing point Identifiers Oxidizing properties

Closed

18-01409

Industrial

Industrial Laboratory needed for cable compression connection testing on 750MCM cable with compression lug. The test connections shall then be heated to 464 degrees Fahrenheit by passing an electric current through the connection. After the temperature equalizes at 464 degrees Fahrenheit, the connection shall be cooled to 75.2 degrees Fahrenheit. A heating phase and a cooling phase shall constitute one cycle. The test connections shall undergo 100 cycles without increasing the resistance beyond that specified.

Please provide the per unit price per sample to conduct such a testing

Closed

18-01402

Industrial

Materials Laboratory needed for leather testing to EN 45545 R21 artificial leather for railvways

Closed

18-01398

Industrial

Italy or Europe NATA Electrical Testing Laboratory with mutual recognition agreement in place for RCM Mark and IEC EMC testing to IEC61000-6-2 and IEC61000-6-4

Closed

18-01394

Industrial

Packaging Laboratory needed for Hexavalent versus Trivalent Chromium Testing in packaging for Toxics in packaging testing.

Closed

18-01392

Industrial

USA Performance Laboratory needed for ANSI testing of half-length, nylon safety harness used for sports climbing according to ANSI Z133 Standard for Safety Requirements in Arboricultural Operations

Closed

18-01381

Industrial

Tests according ISO 12944-1:2018-06 Paints and varnishes Corrosion protection of steel structures by protective paint systems Part 5: Protective paint systems

Closed

18-01377

Industrial

Independent Laboratory needed for wavefront error measurements of parabolic mirrors (FL=50mm, F/0.5) with a central 30-mm hole by interferometric measurement.

Closed

18-01370

Industrial

Independent Third-Party Laboratory needed with testing capabilities to test as per SASO 1959, SASO 1958, SASO 494 for the product - TOILET DEODORANTS BATHROOM ODOR REMOVERS.

Closed

18-01368

Industrial

Textiles Laboratory needed for unsaponifiables testing in jute bags, which are used for coffee transport and storage.

Closed

18-01360

Industrial

Materials Laboratory needed for FTIR microscopy analysis of coating defects, and determination of what the defect is. For example, if the defect is a fish-eye, what is the central spot composed of, e.g. not completely disssolved coating resin, pigment particle, silicone.

Closed

18-01353

Industrial

Laboratory needed for performing the following bench top filtration research study:

Step 1 - Filter Step 2 - PH adjust result of 1 Step 3 - Centrification of result of Step 2 Step 4 - PH adjust result of Step 3 Step 5 - Centrification of result of Step 3

Batches of 1 - 5 gallons of starting material 2 - 3 batches per run.

Closed

18-01352

Industrial

Third-Party Laboratory needed for ASHRAE testing of carbon filter 400x340x25mm to be tested with TBD standard challenge gases. ASHRAE 145.2 Laboratory Test Method for Assessing the Performance of Gas-Phase Air Cleaning Systems: Air Cleaning Devices

Closed

18-01350

Industrial

Performance Laboratory needed for AATCC and ASTM water and blood penetration resistance testing of non-woven used in protective clothing to the following standards: AATCC42 Water Resistance: Impact Penetration Test AATCC127 Water Resistance: Hydrostatic Pressure Test ASTM F1670 Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Synthetic Blood, ASTM F1671 Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174 Bacteriophage Penetration as a Test System

Closed

18-01341

Industrial

Cannabis Company Packaging Laboratory needed for Child-Resistant Certification for Beverage Twist Cap

Closed

18-01339

Industrial

Large Consumer Products Company needs USA Third-Party Laboratory for ASHRAE Testing to the following ASHRAE Standards: ANSI/ASHRAE Standard 145.2-2016 Perf. of Gas Phase Air Cleaning Systems: Air-Cleaning Devices ANSI/ASHRAE Standard 145.1-2015 Perf. of Gas Phase Air Cleaning Systems: Loose Granular Media

Closed

18-01335

Industrial

Materials Laboratory needed for determining the vapor pressure of a chalcogenide glass sample at 800C.

Closed

18-01331

Industrial

FDA GMP Food Laboratory needed for testing of food contact coatings testing to obtain FDA or USDA R-1 approval for a couple coatings. This is for incidental food contact. I was hoping for a quote and rough time table to get this done.

Closed

18-01330

Industrial

Independent Adhesives Test Laboratory needed for confirmation of results from the manufacturing lab for the adhesive performance of a production coated PSA laminate under the following conditions: 180º Peel from stainless steel (PSTC 101), Loop Tack (PSTC 16), Shear -1"x1"x1 kg (PSTC 7) and various chemical resistance tests of pressure sensitive adhesive laminates for under the hood applications.

Closed

18-01329

Industrial

Industrial Analytical Chemistry Laboratory needed for formulation of a heat seal lacquer that would be used industrial production

Closed

18-01326

Industrial

Packaging Laboratory needed for spectral transmission testing on plastic containers to USP <671> Containers - Performance Testing

Closed

18-01314

Industrial

LONG-TERM USA or Korea Polymer Materials Laboratory needed for ASTM Elastomeric Coating properties as per ASTM D6083

Closed

18-01300

Industrial

Asia Mechanical Laboratory needed for burst testing of Air filters used in gas turbines

Closed

18-01296

Industrial

Elastomeric Coating to ASTM D6083 Standard Specification for Liquid Applied Acrylic Coating Used in Roofing

Closed

18-01292

Industrial

Large Corporation needs Performance Laboratory for ANSI Safety Testing to ANSI/ASSE Z359 American National Standard Safety Requirements for Personal Fall Arrest Systems, Subsystems and Components

Closed

18-01286

Industrial

PRODUCT DEVELOPMENT Product Design Company needs India Optical Laboratory for measuring the tint of plastic or glass

Closed

18-01280

Industrial

Environmental Laboratory needed for hydrogen sulphide removal capacity of impregnated granular media to ASHRAE 145.1 Laboratory Test Method for Assessing the Performance of Gas-Phase Air-Cleaning Systems: Loose Granular Media (ANSI Approved)

Closed

18-01278

Industrial

Third-Party Materials Laboratory needed for ASTM testing of hardwood floor cleaner (UL 2759) and restorer (UL 2777). to the following ASTM standards: ASTM D3052-87, ASTM D2047-93, and product efficacy testing in accordance with section 10.2 of UL standard 2759.

Closed

18-01272

Industrial

Materials Laboratory needed for ASTM spontaneous combustion testing of a paint stripping product applied to cloth according to ASTM D6801-07, Standard Test Method for Measuring Maximum Spontaneous Heating Temperature of Art and Other Materials. The paint stripping product to be tested contains 3 solvents (methyl acetate CAS# 79-20-9, dimethyl sulfoxide CAS#67-68-5, and 1,3 dioxolane CAS#646-06-0) and two additives (paraffin wax, and hydroxypropyl methylcellulose). The viscosity for this product is approximately 1,800 cp.

Closed

18-01262

Industrial

Third-Party laboratory needed for biodegradability testing via either ISO 9888 or DIN-EN 29888 methods. Please provide a quote.

Closed

18-01261

Industrial

Materials Laboratory needed for ASTM Testing of Decorative Coating Thermal Insulation Panel to ASTM E2430 .

Closed

18-01256

Industrial

PRODUCT DEVELOPMENT California company needs Packaging laboratory needed for child-resistant CR testing on new mylar pouch with a type of ziploc closure for multiples uses

Please let us know what your general turn around times are as well as costing structure.

Looking forward to working with you,

Regards,

Jane

Closed

18-01249

Industrial

Packaging Laboratory needed for ASTM child resistant certification testing of new cannabis containing beverage line.

Closed

18-01215

Industrial

Materials Laboratory needed for ASTM thermal conductivity measurements of laminate films to ASTM E1530, performed with a TA Instruments DTC-300 or equivalent, at both ambient and elevated temperatures. We would require a calibration report, and bracketing, traceable standards as necessary to justify a Quality decision.

Closed

18-01204

Industrial

Large Corporation needs Materials Laboratory for unknown materials identification to determine if the piece is is glass or acrylic.

Closed

18-01203

Industrial

Paper company needs Packaging Laboratory for the following TAPPI/ASTM testing on corrugated paper bins under standard conditioning, Basis weight analysis, Edge Crush Test ECT and Mullen testing

Closed

18-01200

Industrial

Third-Party Laboratory needed for anti-carbonation certification testing of exterior paint coating

Closed

18-01198

Industrial

LONG-TERM TESTING Laboratory needed for electrostatic discharge ESD testing on ESD protection jackets on a monthly basis.

Closed

18-01194

Industrial

Laboratory needed for ASTM Testing of a non-woven product to ASTM F739-07 Standard Test Method for Permeation of Liquids and Gases through Protective Clothing Materials under Conditions of Continuous Contact .

Closed

18-01193

Industrial

Large corporation needs Laboratory for certification of refrigerators fridges in accordance with US 10 CFR 430.32 Energy and Eater Conservation Standards for the consumption of energy by year

Closed

18-01166

Industrial

Forensics Laboratory needed for failure analysis of a notable color difference between glass bottles used for bottling whiskey including a chemical analysis of the liquid whiskey in the bottles.

Closed

18-01163

Industrial

Materials Laboratory needed for normal and hemispherical emissivity testing as per ASTM E408 Standard Test Methods for Total Normal Emittance of Surfaces Using Inspection-Meter Techniques.The sample will be a coating applied on the aluminum plate or a piece of coating free film.

Closed

18-01153

Industrial

Performance Laboratory needed for ASTM performance testing of work boot to ASTM F2413 Standard Specification for Performance Requirements for Foot Protection.

Closed

18-01132

Industrial

Polymer Company needs Materials Laboratory for ASTM testing of polymer coating films to a) solar Reflectance as per ASTM E 903 and b) as per ASTM E 1225 Standard Test Method for Thermal Conductivity of Solids Using the Guarded-Comparative-Longitudinal Heat Flow Technique

Closed

18-01130

Industrial

Materials Laboratory needed for ANSI, AAMI and ASTM Testing of medical protective gowns made out SMMS Material to ANSI/AAMIPB70 Liquid barrier performance and classification of protective apparel and drapes intended for use in health care facilities and ASTM F739 Standard Test Method for Permeation of Liquids and Gases through Protective Clothing Materials under Conditions of Continuous Contact

Closed

18-01116

Industrial

FDA Registered, GMP Laboratory needed to carry out testing on ion exchange resins.(TOC extraction) to show compliance to US Code of Federal Regulations fTitle 21  Chapter I  Subchapter B  Part 173  Subpart A  §173.25

Closed

18-01108

Industrial

Industrial Laboratory needed for ASHRAE of t air filter as per ASHRAE 52.2 Standard, Testing for HVAC Air Filtration.

Closed

18-01098

Industrial

Third-Party Laboratory needed for ASTM Materials Thermal and Shock Resistance of glass candle holders to ASTM( AMERICAN STANDARD TESTING MATERIAL) ASTM F2179 which is for Thermal and Shock Resistance

Closed

18-01088

Industrial

Third-Party USA Laboratory needed for DIN testing of glass type S1, S2, S3 as per DIN 12116 Resistance to attack by a boiling aqueous solution of hydrochloric acid

Closed

18-01085

Industrial

Packaging Laboratory needed for Child Resistant Packaging testing of boxes used for cannabis product. Please provide quote for one box size.

Closed

18-01084

Industrial

Forensics Laboratory needed for on-site inspection and failure investigation of failed industrial propane-fired heater involved in a fire and also possible testing of an exemplar heater including the storage unit.

Closed

18-01079

Industrial

Large Paint Company needs experience laboratory for total solar reflectance (TSR) testing of coatings applied to Laboratory Applied Testing Panels. Please provide costing.

Closed

18-01072

Industrial

Large Manufacturer needs Physical Laboratory for ASME testing of Fiberglass Product FRP for the following: Lap shear test Compress test Glass content test

Closed

18-01065

Industrial

Materials Laboratory needed for food contact surface testing of polymers PP and PBT nonwoven meltblown to the following FDA Code of Federal Requlations:

-Title 21 CFR-177.1660 INDIRECT FOOD ADDITIVES: POLYMERS, Substances for Use as Basic Components of Single and Repeated Use Food Contact Surfaces POLY (TETRAMETHYLENE TEREPHTHALATE)

-Title 21 CFR-177.1520 INDIRECT FOOD ADDITIVES: POLYMERS, Substances for Use as Basic Components of Single and Repeated Use Food Contact Surfaces Olefin polymers.

Closed

18-01064

Industrial

Laboratory needed for NSF / ANSI testing of water purifier and filter according to NSF/ANSI 177 standard Shower filtration systems Aesthetic effects

Closed

18-01062

Industrial

Dairy Company needs Materials Laboratory for quality control testing of printed laminated film material.

Closed

18-01061

Industrial

Large Industrial Company needs Electrical Laboratory for UL DC short circuit testing at 1500VDC

Closed

18-01058

Industrial

Industrial Laboratory needed for glass testing for the below mentioned details 1. Thickness , 2. Light Stability 3. Boil Test, 4. Penetration Test, 5. Impact Resistance

Closed

18-01057

Industrial

Electrical Laboratory needed for IEC testing for garment use in high voltage environment according to 60895 © IEC:2002 numeral 6.

Closed

18-01046

Industrial

Manufacturer needs Materials Laboratory for ASTM testing of glass bottles and glass jars exported to the US markets.as per ASTM ( AMERICAN STANDARD TESTING MATERIAL) F 2179 Code for Thermal Shock and Resistance.

Closed

18-01044

Industrial

High Tech Firm needs Laboratory with a HALT and thermal chamber to conduct ALT thermal cycling tests We require the thermal chamber to be capable of a ramp rate of 5-10 °C/min and a HALT chamber capable of at least 45°C/min. IMPORTANT NOTE: Please provide dimensions and chamber availability for the month of August

Closed

18-01043

Industrial

Aerospace Laboratory needed for AMS and BMS Testing of aerospace wipers to AMS 3819C Cloths, Cleaning, for Aircraft Primary and Secondary Structural Surfaces and BMS 15-5 Rev G BMS 15-5 - Wiper, Absorbent, Process Cleaning

Closed

18-01035

Industrial

Industrial Laboratory needed for ASHRAE and ASTM testing of air vents and ducting accessories for HVAC. diffuser and sound attenuator ducting accessories for HVAC to ASHRAE 70 Method of Testing the Performance of Air Outlets and Air Inlets or ASTM E477 Standard Test Method for Laboratory Measurements of Acoustical and Airflow Performance of Duct Liner Materials and Prefabricated Silencers

Closed

18-01021

Industrial

Laboratory needed for ANSI compliance testing of six safety labels for ANSI Z535.4 compliance for Color and Text Height and Fonts.

Closed

18-01001

Industrial

Microbiology Laboratory needed for n neutralization confirmation and sanitizer study on antimicrobial coating with 2 strains of the following organisms:

1. Staphylococcus aureus ATCC 6538 2. Pseudomonas aeruginosa ATCC 15442 Contact Time : 5 mins, 10 mins, 30 mins, 60 mins, 2 hours, 4 hours, 6 hours 8 hours and 24 hours. Test surface : stainless steel.

Total no. of coated surfaces : of each test surface Total no. of uncoated surfaces : of each test surface No. of test products : 3 No. of test products details : 3

Closed

18-00988

Industrial

Large Beverage Company needs Third-Party Laboratory for failure analysis of beverage cans to determine root cause of failure (leakers).

Closed

18-00984

Industrial

Materials Laboratory needed for pH and UV longevity testing of adhesive tapes to confirm adhesive tapes longevity/resistance to long-term light exposure..

Closed

18-00971

Industrial

Life Science Laboratory needed for third-party validation testing (physical, microbiology, biological) of manufacturer's specifications of sterile personal protection products including: -Anti-Bacterial (99.9%) -Anti-Fungal -Anti-Static -Ambient Temperature Conducive -Flame Resistant (up to 800°) -Biologically Safe

Closed

18-00970

Industrial

Packaging Laboratory needed for transportation study and ASTM conditioning and environmental simulation testing of shipping containers and boxes to clarify that the 10 boxes must first pass through ASTM D4332-14 ASTM D4332 - 14 Standard Practice for Conditioning Containers, Packages, or Packaging Components for Testing and then through ASTM D4169-16 # 1 Environmental Conditioning (Static) per ASTM D4332-14 ASTM D4169 - 16 Standard Practice for Performance Testing of Shipping Containers and Systems, (Laboratory Ambient Temperature & Humidity for 6 hours) 40°C ± 2°C @ 90% RH ± 5% RH for 48 hours - Tropical 60°C ± 2°C @ 15% RH ± 5% RH for 48 hours - Desert -18°C ± 2°C @ Uncontrolled RH for 48 hours - Frozen # 2 Shipping and Handling Simulation (Dynamic) per ASTM D4169-16 Distribution Cycle 13, AL 1 - Test Sequence This test sequence inv

Closed

18-00969

Industrial

Materials Laboratory needed for DIN Testing of technical fibers Meta Aramid Yarn for DIN certification

Closed

18-00961

Industrial

ISO / iEC 17025 Laboratory needed for ISO Anti-vibration glove test to ISO 10819 Mechanical vibration and shock Hand-arm vibration Measurement and evaluation of the vibration transmissibility of gloves at the palm of the hand

Closed

18-00959

Industrial

URGENT Industrial Laboratory needed for ASTM testing of EPDM waterproofing membrane splice samples in accordance with ASTM D 7272 Standard Test Method for Determining the Integrity of Seams Used in Joining Geomembranes by Premanufactured Taped Methods. Sampling will be for a 0.35 m x 0.45 m piece which will be cut as required in your lab. I will need to conduct 5 samples for Shear and another 5 for peel.This subject is very urgent from my side, so i would appreciate your soonest feedback with any requirement for you to prepare a quote

Closed

18-00956

Industrial

CNAS/ NATA Accredited Construction Materials Testing Facility needed for BS Glass impact test based on BS EN356 Glass in building. Security glazing. Testing and classification of resistance against manual attack

Closed

18-00953

Industrial

Electrical Laboratory needed for IEC design testing to IEC61109 of High Voltage Equipment insulators

Closed

18-00952

Industrial

Packaging Laboratory needed for the follow ASTM packaging testing

- ASTM D-4169 o 28 cases

- Tensile Testing per ASTM F88 method C o 740 individual samples o Sample would need to be cut from pouches - Bubble Leak Testing per ASTM F2096 o 185 individual test samples - Vacuum testing o 37 bottle samples - Removal torque testing o 37 bottle samples

Closed

18-00951

Industrial

UKAS Accredited Industrial Laboratory needed for cable tray testing including the following:

1. Salt spray test - 600hours - UKAS accredited- Salt mist test, ASTM B117 2. SWL test 3. Thickness of the material. 4. Powder coated thickness.

Closed

18-00949

Industrial

Pharmaceutical Company needs Packaging Laboratory for drop testing of two different shippers with different configurations.

Closed

18-00945

Industrial

Industrial Laboratory needed for European Committee for Electrotechnical Standardization CENELEC compliance testing for generators.

Closed

18-00937

Industrial

Industrial Laboratory needed for ASTM fire resisting duct work testing to ASTM E2336-16 Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems and ASTM E2816-18 Standard Test Methods for Fire Resistive Metallic HVAC Duct Systems

Closed

18-00924

Industrial

LONG-TERM TESTING Industrial Laboratory needed for evaluation of high-density polyethylene HDPE dust to get a report on flammability to determine the level of dust collection protection required and to share with insurance companies.

Closed

18-00919

Industrial

Packaging Laboratory needed for child-resistant tin packaging testing to ASTM D3475 Standard Classification of Child-Resistant Packages

Closed

18-00917

Industrial

Large Pharma needs Nanotechnology Laboratory for analysis of inorganic salts.

Closed

18-00914

Industrial

Industrial Laboratory needed for split unit air conditioner energy performance testing in conformance with standard (AS/NZS 3823.1.1:1998 ,AS/NZS 3823.2:2011)

Closed

18-00908

Industrial

Bioanalytical Laboratory needed for Cellular Adherence R&D Study on 2D glass samples with 4 different types of nanotechnology surface coating on 3 different types of cells. . On each surface, we would like to test 1) cellular adherence to the surface, and 2) cellular proliferation rate. The cell types we want assessed are: 1) HeLa (epithelial) cells 2) BAE-1 (endothelial) cells 3) SH-SY5Y (neuroblast) cells

The 2D glass samples would have a thin surface coating of: 1) Nothing (plain glass control) 2) Proprietary 'adhesive' coating #1 (non-hazardous, non-toxic) 3) Proprietary coating #2 (non-hazardous, non-toxic) 4) Commercial Adhesive coating (control #2)

It is important that testing methods include: - microscopic imaging (i.e. provide us with images) of each cell type on each of the 4 surfaces outlined above at three dif

Closed

18-00903

Industrial

Industrial Laboratory needed for GMW cable testing to GM Worldwide Engineering Standard GMW14327-2015

Closed

18-00902

Industrial

Food Laboratory needed for shelf-life study of fresh produce fruit and vegetables.Shelf life test comparing different packaging supplied for test including Active Packaging, regular pe packaging and no packaging , at room temperature and cold storage

Closed

18-00900

Industrial

Third-Party Laboratory needed for ANSI safety testing of ladders to ANSI A14.3 American National Standards for Ladders - Fixed - Safety Requirements

Closed

18-00895

Industrial

Automotive Laboratory needed for SAE testing of truck air dryer as per SAE J2383 Air Dryer Installation Procedure testing procedure.

Closed

18-00879

Industrial

Electrical Laboratory needed for SAE Certification testing to certify telematics products to SAE J1113 Electromagnetic Compatibility Measurement Procedures and Limits for Components of Vehicles, Boats (up to 15 m), and Machines and SAE J1455 Environmental Practices for Electronic Equipment Design in Heavy-Duty Vehicle Applications and . It is a telematics device with a mining application project pending.

Closed

18-00853

Industrial

I am looking for someone who can perform testing on labels for wire and fuel line markers to Mil-T-9906C MIL-T-9906C, MILITARY SPECIFICATION: TAPE, IDENTIFICATION, AEROSPACE VEHICLE TUBING MARKER (08-DEC-1988),

Closed

18-00842

Industrial

Packaging Laboratory needed for performance testing of packaging to ASTM Testing D4169 Standard Practice for Performance Testing of Shipping Containers and Systems

Closed

18-00838

Industrial

Industrial Laboratory needed for the testing for strobe lighting used for emergency services to the following Test Methods SAE J595, SAE J845, CALIFORNIA table

Closed

18-00835

Industrial

Bonding validation by ageing test according to appendix 3 of the DVS1618 is needed for glazing that is produced for the train industry.

Closed

18-00830

Industrial

Materials Laboratory needed for failure analysis of construction materials adhesive that moisture has infiltrated compared to the same adhesive in ideal conditions to determine if the adhesives have failed due to weather, product reaction with other chemicals, etc. Adhesive used in construction industry applications.

Closed

18-00826

Industrial

Packaging Laboratory needed for California Child Resistant compliant packaging testing of 3 different sizes of compostable bags used for marijuana distributors.

Closed

18-00822

Industrial

Materials Laboratory needed for flash point testing for coating product by closed-cup test method.

Closed

18-00816

Industrial

Auto Parts Manufacturer needs Automotive Laboratory for DOT Testing of windshields

Closed

18-00811

Industrial

Third-Party Laboratory needed for environmental simulation and salt spray testing of a variety of products in a variety of different environments including climate controlled environments to deserts for identification tags . Testing is being performed to guarantee indoor and outdoor life in different environments.

Closed

18-00798

Industrial

Materials Laboratory needed for ASTM adhesion testing for metal coatings on a metal substrate to ASTM D4541, Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers

Closed

18-00793

Industrial

Laboratory needed for SAE testing of reflective wrap for harnesses and other applications. Need to test the thermal effectiveness per SAE J2302 Thermal Effectiveness of Sleeve Insulation

Closed

18-00789

Industrial

Manufacturer needs Packaging Laboratory for burst and leak testing of aerosol cans.

Closed

18-00786

Industrial

Gloves manufacturer needs Laboratory for ANSI puncture testing of glove for ANSI A7 and Puncture 5,

Closed

18-00771

Industrial

Packaging Laboratory needed for packaging study iof food pre-formed pouches / bags filled with Nitrogen gas to increase the shelf life of the food product. The quantity of the oxygen presence in the pouch also needs to be tested.. .

Closed

18-00770

Industrial

Packaging Laboratory needed for child resistance safety testing of a variety of jars, pouches and cartons used in packaging medicinal cannabis products.

Closed

18-00758

Industrial

Manufacturer needs Laboratory for investigation including heavy metal testing to see if incident was work related. Employee was welding a piece of metal that they claim made them sick. Therefore, we would like heavy metals testing. May need site visit to our facility.

Closed

18-00756

Industrial

Large food processor needs Analytical Chemistry Laboratory for identification testing of unknown powder sample collected from our equipment in out production facility. It could be made up of vegetable oil(s), protein and /or silicon oil. We are trying to determine what exactly is collecting to make up this powder.

Likely require a GC analysis of the product. More information can be provided if there is interest in analyzing this unknown product.

Closed

18-00737

Industrial

Safety Laboratory needed for ANSI / ISEA cut resistant testing of safety gloves to, ANSI / ISEA 105-2016, standards

Closed

18-00735

Industrial

Third-Party Laboratory needed for ASHRAE testing of carbon grid block/ honeycomb filter 594x594x95mm to be tested with toluene, H2S and SO2. ASHRAE 145.2 Laboratory Test Method for Assessing the Performance of Gas-Phase Air Cleaning Systems: Air Cleaning Devices

Closed

18-00729

Industrial

Large Corporation needs Performance Laboratory for ASHARE testing of an air cleaning device to ASHARE 145.2 Laboratory Test Method for Assessing the Performance of Gas-Phase Air Cleaning Systems: Air Cleaning Devices

Closed

18-00719

Industrial

Safety Laboratory needed for ANSI/ ISEA testing of construction safety glasses to ANSI/ISEA Z87.1-2015 American National Standard for Occupational and Educational Personal Eye and Face Protection Devices

Closed

18-00713

Industrial

Materials Laboratory needed for ASTM Testing of several waxes to the following ASTM Standards: Melting Point, Ash Content, Congealing point (ASTM D938) Drop point (ASTM D3954) Penetration (ASTM D1321) Acid value (ASTM D1386) Particle Size (ASTM D185, <106 micron, >2000 micron)

Closed

18-00711

Industrial

Pharmaceutical Company needs Packaging Laboratory needed for ASTM burst testing on around 90 plastic heat-sealed 8 x 5 packages as part of the qualification for our sealing process according to ASTM F1140 Standard Test Methods for Internal Pressurization Failure Resistance of Unrestrained Packages

Closed

18-00707

Industrial

Environmental Toxicology needed for ecotoxicity studies of industrial waste as well as the composition of dangerous, hazardous substances in waste.including 1. Methyl acrylate, Cas No .: 96-33-32. Methyl methacrylates, Cas No .: 80-62-63. n-octylmercapta, Cas No .: 111-88-64. 2H-benzotriazole Creole, No. 2440-22-45. 2,2- (2-methylpropionitrile), CAS No.: 78-67-

Closed

18-00704

Industrial

Safety Laboratory needed for earplug Noise Reduction Rating testing compliant with ANSI STD S3.19-1974 for a new earplug design. Mean attenuation values of earplug design at 125hz, 250hz, 500hz, 1000hz, 2000hz, 3150hz, 4000hz, 6300hz, 8000hz as well as Standard Deviation in dB for each as explained in ANSI "Method for the Measurement of Real-Ear Protection of Hearing Protectors"

Closed

18-00700

Industrial

Company needs forensics laboratory for industrial hygiene investigation for heavy metals in a specific garment and respirator filter f

Closed

18-00699

Industrial

Safety Laboratory needed for ASTM testing of safety shoes to ASTM standards including (e.g. impact resistance, compression resistance).

Closed

18-00697

Industrial

Polymer Laboratory needed for ASTM testing of a polyimide film with a proprietary coating for printed circuit boards including reflectivity with the integrated sphere measurement testing for scattered light

Closed

18-00685

Industrial

Laboratory needed for comparison study of the mechanical and physical properties of several different PVC extruded tubes for urometer, column strength, elasticity, tensile strength, crush and to the extent possible, chemical composition.

Closed

18-00677

Industrial

Large Industrial Company needs Physical Laboratory for stress relief testing not exceeding 4% per 1000h at initial force making 70% of maximum force corresponding to ultimate tensile strength.

Closed

18-00674

Industrial

URGENT Large Corporation needs Industrial Forensics Laboratory for failure analysis and identification of contaminate affecting composites part quality.

Closed

18-00672

Industrial

Packaging Laboratory needed for ISTA testing of 3 different Thermal Passive Package as per ISTA 7D ambient condition.

Closed

18-00664

Industrial

Materials Laboratory needed for NFPA and ANSI testing of 3 different types of personal protective equipment and rescue equipment harnesses. to the following standards NFPA 1893:2017 and ANSI Z359.11:2014.

Closed

18-00651

Industrial

Large Pharma needs CPSC Packaging Laboratory for child resistant and senior friendly testing of blisters and bottle packs.

Closed

18-00648

Industrial

LONG-TERM TESTING Pharmaceutical Laboratory needed to assay for the presence of cytotoxic drugs on the exterior packages (internal bottle), external cardboard packaging, delivery totes for a number of different drugs and lot numbers over several months

Closed

18-00619

Industrial

Consumer Products Laboratory needed for CPSIA, California Prop65 and ASTM testing of children's robotic toys ASTM F963 full test( Part1, Part2, Part3),16CFR1505: Electrically operated toys safety test and CPSIA & Cali Pro65 test.

Closed

18-00612

Industrial

ISO 9001 MATERIALS LABORATORY NEEDED FOR CERTIFICATE OF ANALYSIS PROPERTIES TESTING OF 23,120 SUSPENSION, RIGID AND POLYMER INSULATORS.

Closed

18-00592

Industrial

Manufacturer needs Mechanical Laboratory for mechanical testing of PVC and XLPE (Cross linked polyethylene) cable includingTensile and elongation tests and water absorption tests

Closed

18-00589

Industrial

Materials Laboratory needed for fiberglass pool.coating testing to 3 ASTM Standards ( ASTM D4086, ASTM E1477, ASTM E1347) to determine a dry lightness level (CIE L value) of 80.0 or greater and a wet luminous reflectance value (CIE Y value) of 50.0 or greater, as determined by test results provided by the manufacturer, utilizing testing methodology from American Standard ASTM D4086, ASTM E1477, ASTM E1347.

Closed

18-00566

Industrial

Medical Device Laboratory needed for ISO Testing on apparatus used on ventilator according to ISO 5356-1 Anaesthetic and respiratory equipment Conical connectors Part 1: Cones and sockets

Closed

18-00541

Industrial

Packaging Laboratory need for ethyl lactate migration from printed substrate. Determination of rest solvents in the printed aluminium foil, including ethyl lactate.

Closed

18-00525

Industrial

Laboratory needed for compostability testing of plastic packaging to CAN/CSA-Z76.1-M90 (Canadian Standard) or US Standard 1700.15 and ASTM D6400 Compostability test

Closed

18-00512

Industrial

Accredited Laboratory needed for Anti vibration glove testing according to ANSI/ASA S2.73 or ISO 10819, Mechanical vibration and shock - Hand-arm vibration

Closed

18-00505

Industrial

Large corporation needs NABL Microbiology Laboratory for anti viral efficacy of paint against certain viruses.

Closed

18-00503

Industrial

Large Corporation needs Laboratory for the evaluation of a material used in the manufacturer of sanitary parts. The material is not homogeneous.The tests needed include 1.Multi-axial testing 2.Anistropic material properties determination 3.Viscoelastic properties 4.Strain rate dependent properties 5.Endurance testing

Closed

18-00500

Industrial

Third-party Laboratory needed for ASTM Testing of woven high reflective breathable membrane to ASTM E2178.Standard Test Method for Air Permeance of Building Materials

Closed

18-00495

Industrial

Industrial Laboratory needed for V2F rig testing for grease

Closed

18-00493

Industrial

Industrial Laboratory needed to provide quote for heavy metals testing in printing materials such as ink, paper, varnish, starch for Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr (VI) Polybrominated biphenyl (PBB)

Polybrominated diphenyl ethers (PBDE) Bis(2-ethylhexyl) phthalate (DEHP) Butyl benzyl phthalate (BBP) Dibutyl phthalate (DBP) Diisobutyl phthalate (DIBP)

Closed

18-00483

Industrial

Industrial Laboratory needed for TJ2384 SAE testing for 15 air dryers

Closed

18-00474

Industrial

Polymer Laboratory needed for physical testing of Polycarbonate PC extruded sheets including UV, etc.

Closed

18-00470

Industrial

Materials Laboratory for tempered glass testing for possible manufacturing deficiencies

Closed

18-00465

Industrial

Engineering Firm needs Polymer Laboratory for shelf-life testing for degradation inpolyethylene film to be used for hygiene industry having oxo-biodegradable additive.

Closed

18-00463

Industrial

Materials Laboratory needed for plastics testing. 1. NFP 92 503 Electrical burner test used for flexible materials thickness no more than 5mm 2. NFPA 286 Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth 3. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

Submit Response

18-00455

Industrial

Industrial Laboratory required which can test earthing enhancing chemical compound as per IEC 62561-7 Lightning protection system components (LPSC) - Part 7: Requirements for earthing enhancing compounds 1) Leaching Test

2) Determination of Sulphur

3) Determination of resistivity

4) Corrosion test

Closed

18-00454

Industrial

Industrial Laboratory needed for DIN testing of ethanol- and isopropyl alcohol-based washer fluids tested for boiling range according to DIN 53171 Solvents for paints and varnishes - Determination of distillation characteristics (boiling range and boiling temperature as a function of distilled volume)

Closed

18-00449

Industrial

Food Company needs Materials Laboratory needed for migration studies on plastic food liner bags to test for compliance with EU Food contact regulations.

Closed

18-00440

Industrial

Microbiology Laboratory needed for 5 viral clearance studies on air purifier 1. Canine Calicivirus 2. H5N1_Influenza A Subtype. 3. H7N9 Avian Influenza 4. Human Corona virus 5. zika virus.

Closed

18-00435

Industrial

Materials Laboratory needed for plastic resin testing to determine the type of plastic resin and the melting temperature of plastic regrind.

Closed

18-00427

Industrial

Materials Laboratory needed for thermal conductivity testing and heat capacity testing on Insulation pulverized limestone products

Closed

18-00424

Industrial

Consumer Products Laboratory needed for compliance testing of two different candles with coconut wax and 2 separate fragrances to international safety standards including:

-safety of the containers that will be used Flammability) -wick size that should be used for both wood and cotton wicks including whether or not an additional wick is required? Is the candle burning safely, cleanly and at the correct pace? -How many hours of burn time

We have two fragrances and three separate containers. We are looking for our candles to achieve the following: when it eventually burns itself out, all wax should be burned from the container including the edges. It should have a steady flame that is not too high or low and that burns clean and not too fast.

Container Candles testing needed. Candles poured in coconut bark (natural and lacque

Closed

18-00423

Industrial

Polymer Laboratory needed for ASTM Testing to 3 ASTM Standards: ASTM D5526 ASTM D5988 ASTM D6691

Closed

18-00418

Industrial

Performance Laboratory needed for AHAM verification of CADR (Clean Air Delivery Rate) for air purifirers

Submit Response

18-00381

Industrial

Packaging Laboratory needed for UN Drop testing for packaged goods using new tape to UN1903, DISINFECTANTS, LIQUID, CORROSIVE, N.O.S.,

Closed

18-00374

Industrial

LONG-TERM TESTING Disposable plastics company needs microbiology laboratory for ASTM biodegradability testing of a wide range of plastic disposable products to ASTM D5511-11 Standard Test Method for Determining Anaerobic Biodegradation of Plastic Materials Under High-Solids Anaerobic-Digestion Conditions

Closed

18-00372

Industrial

Performance Test Laboratory needed to verify the physical performance of spirometer as per ATS/ERS guideline: Standardisation of spirometer,

Closed

18-00371

Industrial

Third-Party Materials Laboratory needed to test adhesion of tape to Pressure Sensitive Tape Council PSTC Standards: 180 peel to steel and 180 peel to self.

Closed

18-00369

Industrial

Packaging Laboratory needed for Child Resistant packaging certification testing for a paperboard box.

Closed

18-00368

Industrial

Third-Party Laboratory needed for ASTM coatings testing to ASTM G 122 Standard Test Method for Evaluating the Effectiveness of Cleaning Agents.

Closed

18-00358

Industrial

Third-party Packaging Laboratory needed for fluoronation gassing for determination of barrier properties for tooth paste like product

Closed

18-00348

Industrial

Engineering Firm needs Materials Laboratory for ASTM Light Reflectance Value Testing to ASTM E1347 - 06(2015) Standard Test Method for Color and Color-Difference Measurement by Tristimulus Colorimetry

Closed

18-00346

Industrial

Large corporation needs Materials Laboratory for ASTM Solar Reflectance Testing of water proofing paint: 1) Solar reflectance index (SRI value) in accordance -with ASTM E1980-01 2) Degree of solar reflectance in accordance with ASTM E-891:

Closed

18-00323

Industrial

Performance Laboratory needed for performing glove cut test

Closed

18-00319

Industrial

NEW PRODUCT DEVELOPMENT Packaging Laboratory needed for advisory and testing services on a new beverage product.

Closed

18-00315

Industrial

Third-Party, Packaging Laboratory needed for child resistant caps testing for the downward force and torque required to remove the caps need to be within defined parameters.

We would like to have of our vials to check the downward force and torque.

Closed

18-00313

Industrial

Accredited laboratory needed that can provide 3rd party fire accreditation testing for fire retardant coatings.

Closed

18-00310

Industrial

Industrial Laboratory needed for metallic value pressure testing to BS EN 12266-1:2012, P11(Annex A.3) and P12 (Annex A.4), Industrial valves. Testing of metallic valves. Pressure tests, test procedures and acceptance criteria. Mandatory requirements

Closed

18-00309

Industrial

Industrial Materials Laboratory needed for ASTM Abrasion Resistance Testing to ASTM D4060-14;

Closed

18-00306

Industrial

EPA Environmental Laboratory needed for air sampling tube testing to EPA TO-17 test on 90 tubes for Transfluthrin. Please provide quote that describes: 1.) How the standard curve will be produced (how many points in the curve, limit of detection and limit of quantitation) 2.) How many control samples will be used (probably 5-10%; should be included in the test method) 3.) Coefficient of variability For each tube we have information on the total air volume collected in that tube (stop time ? start time x flow rate).

Closed

18-00303

Industrial

Large Organization needs Medical Device Laboratory for comparison study on 3 or 6 Surgical gowns suppliers testing against BS EN 13795 , including Wet Penetration , Dry Penetration, Mircobial cleanliness , particulant matter& linting , liquid penetration and tensile strength (with various BS En references to these)

Closed

18-00302

Industrial

Automotive Industrial Laboratory needed for physical testing of powder coated metal according Ford WSS-M2P190-A Interior painted part of handbrake including 3.4.6 FLTM BN 107-01 Cure test 3.5 FLTM BN 155-01 Abrasion and paint wear resistance 3.4.9 FLTM BO 116-01 Resistance to Fade 3.4.10 FLTM BI 107-05 High performance Paint adhesion 3.4.13 SAE J365 Resistance to Marring

Closed

18-00301

Industrial

Physical Laboratory needed for ISO Abrasion resistance and durability tests for Fishing nets as per ISO 1805:2006 Fishing nets - Determination of mesh breaking force of netting (ISO 1806:2002 and Fishing nets Determination of breaking force and knot breaking force of netting yarns (ISO 1805:2006). The testing should be done under dry and wet conditions in salted water.

Closed

18-00296

Industrial

PRODUCT DEVELOPMENT Microbiology Laboratory needed for particulate and virus/bacteria count from an air purifier to be manufactured

Closed

18-00288

Industrial

Industrial Laboratory needed for testing and evaluation of automotive lighting systems, lamps and mirrors. This testing includes assisting in the development of company's own laboratory including design of facilities and purchase of equipment.

Closed

18-00286

Industrial

Large Healthcare Company needs Pharmaceuticals Laboratory for SMEPAC/Surrogate powder test as part of performance testing of equipment. using lactose monohydrate as surrogate powder. The test will be performed on 3 units: 1 isolator (OEL: 0.1ug/m3) and 2 downflow booths(OEL: 100ug/m3). The estimated total number of samples for each unit is 26.

Closed

18-00279

Industrial

Medical device manufacturer seeking testing compliant with ISO 15747:2010, Plastic containers for intravenous injections relating to safe handling and the physical, chemical, and biological testing of plastic containers for parenterals. Please inquire for further information on the product we are testing.

Closed

18-00274

Industrial

ISO 17025 Environmental Chemistry Laboratory needed for water testing for quantification of 1-(2,6-dimethylphenoxy)-2-(3,4-dimethoxyphenylethylamino)propane from a water sample. Unknown # of samples. Water is likely surface/ground water or industrial waste water. No reporting limit is specified.

Closed

18-00272

Industrial

EPA Environmental Laboratory needed for emission testing as per USEPA methods 29, 26a and 23a

Closed

18-00258

Industrial

Sensory Laboratory needed for sensory tests for odour and off-flavour on food packaging.

Closed

18-00257

Industrial

Food Packaging Laboratory for food contact applications analysis and certificate of declaration of conformity for paperboard products according to the following International regulations: Framework Regulation European Parliament and Council Regulation (EC) N:o 1935/2004/EC

BfR recommendation no. XXXVI

FDA regulations , 21 CFR, parts 170-189 ? French food contact legislation ? Regulation Packaging and Packaging Waste directive 94/62/EY (heavy metals) ? Directive 1907/2006 and 552/2009 (Phtalates in toys) ? EN 71-3 (Safety of toys: migration of certain elements) ? EN 71-9 (Safety of toys: organic chemical compounds) ? RoHs Directive EU Directive 2002/95/EC (including arsenic) ? Microwave-use ? MOH

Kindly specify the content of the test packages and state the test which you are able to perform. In addition do you

Closed

18-00254

Industrial

Materials Laboratory needed to measure the roughness and deformation of a concave mirror surface which is located on one ends of a 4-mm rod. The size of the concave mirror is 0.1mm.

Closed

18-00241

Industrial

Performance Laboratory needed for ASHRAE efficiency testing of elecctrostatic filters to Ashrae 52.2 Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size

Closed

18-00237

Industrial

Pharmaceutical Company needs packaging laboratory for container closure integrity for container.packing : 10/20 L glass bottle Volume: 1-16L

Closed

18-00212

Industrial

URGENT Company needs third-party Analytical Chemistry Laboratory for recertification testing bonding primer in which the shelf is set to expire today. The manufacturer of the primer informed us that if we can get a third party Analytical Service to recertify the primer for another 30 days, then we won't have to dispose of it and can use it.

Closed

18-00200

Industrial

Physical Laboratory needed for ASTM Testing of phenol impregnated glass fiber cloth to (ASTM 297, sandwich tensile test).

Closed

18-00197

Industrial

LONG-TERM TESTING Mechanical Laboratory needed for Burst testing for 6 models of valves for ABS certification to verify design wall thickness at 4,200 lbs.

Closed

18-00188

Industrial

LONG-TERM TESTING Materials Laboratory needed to measure the haze of a sapphire coating on glass

Closed

18-00181

Industrial

Heavy Equipment Company need Geology Laboratory for rare earth mineral analysis

Closed

18-00174

Industrial

Mechanical Laboratory needed for engine testing to determine how the connected exhaust system affects the brake power of the engine and to calculate the power required to push the exhaust gas out

Closed

18-00166

Industrial

Materials Laboratory needed for infrared transmittance testing on on laminated glass.

Closed

18-00163

Industrial

Polymer Laboratory needed for ASTM testing of polypropylene fibers to meet ASTM standards C1116/C116M, C1609, D638, and any others that may need to be done on this product.

Closed

18-00160

Industrial

Packaging Laboratory needed for child resistant packaging certification of jars

Closed

18-00150

Industrial

URGENT Large Industrial Machinery Company needs Materials Laboratory for impact, failure analysis and identification of the cause of filtration liquid turning yellowish with use of white felt bags used for filtrating liquids We need to understand the cause and if there's any impact to the liquids being filtered

Closed

18-00145

Industrial

Packaging Laboratory needed for root cause analysis / failure investigation on leakage defect on manufactured aluminum can.

Closed

18-00141

Industrial

Chemical Manufacturer needs Laboratory for GLP testing to support REACH registration of a non hazardous, insoluble, high melting point solid including the following tests: 1. Granuliometry 2. Density 3 Flash Point 4 Self Ignition

Closed

18-00119

Industrial

Materials Laboratory needed for NFPA Testing of 2 fabrics to NFPA 1971, Heat & Thermal Shrinkage (%) NFPA 1971

Submit Response

18-00116

Industrial

Material Laboratories needed for ISO leaching rate testing of coatings to ISO method 10890:2010 of marine anti-fouling paint.

Closed

18-00115

Industrial

Large manufacturer needs Textiles Laboratory for ASTM Testing of 4 fabric varieties to ASTM D2582 Puncture-propagation tear

Submit Response

18-00089

Industrial

Fine Furnishings Company needs Materials Laboratory for ASTM Testing to ASTM D648 Heat Deflection Temperature of Plastics

Closed

18-00087

Industrial

LONG-TERM TESTING Packaging Laboratory needed for multiple packaging and transportation studies such as ISTA 3A Packaged-Products for Parcel Delivery Shipment test and ISTA 6-Amazon.com Parcel delivery test.

Closed

18-00084

Industrial

Metrology Laboratory needed for calibration Reference Sound Source Fan, B&K model 4202 in a Hemi-Anechoic sound chamber per ANSI S12.5:2006/ISO 6926:1999 or newer version if available.

Closed

18-00065

Industrial

Consumer Products Safety Laboratory needed for child safety testing of several push and turn containers

Closed

18-00052

Industrial

USA Large Beverage Company needs Materials Laboratory for adhesive coat weight testing. Similar to ASTM F 2217 or FINAT Test Method 12

Closed

18-00047

Industrial

Materials Laboratory needed for analysis of the variation in dielectric strength measurement and surface analysis of an aluminum substrate that has a dielectric and various graphic inks printed on one side. The surface needs to be analyzed for variation in thickness of the inks and dielectric across a section. Multiple samples need to be evaluated to determine the percent change in thickness across a set of samples. Also, each individual layer of graphic ink needs to be tested for dielectric strength. Each individual ink can will be printed on it's own aluminum sample.

Closed

18-00045

Industrial

lead content test for metal pitcher

Submit Response

18-00018

Industrial

FDA GMP Consumer Products Laboratory needed for lead residue testing in brass food bowls (that have been manufactured in India

Closed

18-00014

Industrial

URGENT 3rd-party Laboratory to perform automotive SAE J2064 hose assembly testing (permeability and/or coupling integrity tests) using 1234yf refrigerant.

Closed

17-02000

Industrial

Polypropylene film manufacturer needs Sensory Laboratory for odor profiling on it' s polymer products.

Closed

17-01996

Industrial

Pharmaceutical company needs laboratory for USP compendial testing of HDPE Bottle as per Current USP 661.1 & 661.2 compliance methods.,

Closed

17-01988

Industrial

Polymer Laboratory needed for ASTM thermal conductivity testing of epoxy polymer matrix composites

Closed

17-01971

Industrial

Materials Laboratory needed for fire testing of automotive nylon fuel lines

Closed

17-01959

Industrial

Plastics Laboratory needed for urethane testing to HKMC spec MS300-55 (release of volatile organic compounds) testing on a UVA-cured acrylated urethane.

Closed

17-01955

Industrial

Materials Laboratory needed for REACH testing of epichlorohydrin according to REACH requirements (EUROPE regulation)

Closed

17-01944

Industrial

Physical Laboratory needed for UL555 Fire Damper Test and UL555S Smoke Damper Test

Closed

17-01943

Industrial

Medical Device Laboratory needed for ASTM Testing of Protective Clothing to the following standards: ASTM F1670/F1670M Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Synthetic Blood, ASTM F1671/ F1671M Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174 Bacteriophage Penetration as a Test System, ASTM D882 Standard Test Methods for Tensile Properties of Thin Plastic Sheeting, ASTM F1342/ F1342M Standard Test Method for Protective Clothing Material Resistance to Puncture, ASTM D1004 Standard Test Method for Tear Resistance (Graves Tear) of Plastic Film and Sheeting

Closed

17-01937

Industrial

Large Manufacturer needs A2LA Materials Laboratory for ASTM Materials Testing to following ASTM Test Methods: ASTM D695 Compressive strength, ASTM D2990 Resistance to creep, ASTM E328 Stress relaxation properties

Closed

17-01935

Industrial

Materials Laboratory needed for comparison testing of a new coating for light transmissivity test done on two pieces of glass coated with the old coating vs a new coating.

Closed

17-01932

Industrial

Laboratory needed for Clean Air Delivery Rate CADR testing on room purifier according to ANSI/AHAM AC-1-2015).

Closed

17-01930

Industrial

Automotive Laboratory needed for SAE fuel filter performance testing per SAE1985/SAEJ905, Fuel Filter Test Methods

Closed

17-01925

Industrial

Mechanical Laboratory needed for SAE testing of gasket to SAE J2659 (Test Method to Measure Fluid Permeation of Polymeric Materials By Speciation).

Closed

17-01922

Industrial

Consumer Products Laboratory needed for child safety and hygiene testing on 4mm corrugated plastic product with rounded edges that children older than 3 years can use to handle.

Closed

17-01915

Industrial

LONG-TERM TESTING Physical Laboratory needed for ISO tear and cut resistance testing to ISO Standards: ISO EN388:16 clause 6.4 for tear resistance ISO EN388:16 clause 6.3 for cut resistance (following EN ISO 13997 procedure)

Closed

17-01893

Industrial

Large Manufacturer needs Laboratory for SAE testing of fuel gasket material tested per SAE J2659 to see if it qualifies as a low permeation material per EPA and CARB evaporative emissions rules.

Closed

17-01892

Industrial

Materials Laboratory needed for ASTM thermal conductivity testing for thermal insulation of stone wool product. ( Rock wool)

Closed

17-01871

Industrial

LONG-TERM TESTING Large Manufacturer needs environmental laboratory for GWP (Global warming potential) and/or ODP (ozone depletion potential) measurements

Closed

17-01869

Industrial

Packaging Laboratory needed for semi-conductive/static dissipative L2 testing of flexible intermediate bulk containers) FIBC liner

Closed

17-01864

Industrial

Laboratory needed for respirator performance testing with powdered fentanyl.

Closed

17-01859

Industrial

Laboratory needed to provide a quotation for testing that confirms pass/fail criteria for RoHS. Specifically, we are interested in identifying the following analytes: Lead, Mercury, Cadmium, Hexavalent Chromium, Polymbrominated Biphenyls, Polybrominated Diphenyl Ethers, Bis(2-ethylhexyl) Phthalate, Benzyl Butyl Phthalate, Dibutyl Phthalate, and Diisobutyl Phthalate.

Submit Response

17-01856

Industrial

Printing company needs materials laboratory for a research study to determine the best adhesion to bottle and pouch components There 2-3 pressure materials to test on each component to learn which material works best yielding 1 material for both components.

Closed

17-01849

Industrial

Laboratory needed for UL compliance testing of regulators to UL 252.Standard for Compressed Gas Regulator Accessories Inlet pressures up to 110bar

Closed

17-01847

Industrial

Manufacturer needs Analytical Chemistry Laboratory for testing to determine the purity of beeswax.

Closed

17-01839

Industrial

URGENT Packaging Laboratory needed for testing product's packaging to ensure it adhere's to North American Child resistant packaging standards. (i) Canadian Standards Association Standard CAN/CSA-Z76.1-M90, entitled Recloseable Child-Resistant Packages, published January 1990, as amended from time to time,

(ii) European Standard EN 28317:1992, entitled Child-resistant packaging. Requirements and testing procedures for reclosable packages, as adopted by the European Committee for Standardization on October 30, 1992, recognized by the British Standards Institution, and effective February 15, 1993 and by the Association française de normalisation, and effective December 20, 1992, and which reiterates fully the international standard ISO 8317:1989, as amended from time to time, and

(iii) Code of Federal Regulations (United States), Tit

Closed

17-01815

Industrial

Electrical Laboratory needed for fir safety of electrical radiant heating systems and its ability to start a fire when installed in domestic or Commercial applications.

Closed

17-01809

Industrial

Packaging Laboratory needed for DOT UN box design qualification testing. The packaging manufacturer shall achieve successful test results for the design qualification testing at the start of production of each new or different packaging.

Closed

17-01802

Industrial

FDA cGMP packaging laboratory needed for polymer film heat shrinkage testing

Closed

17-01797

Industrial

Nitro Cold Brew Coffee in a can requires, head space gas testing and dissolved oxygen for beverage. Want to understand the oxygen level in the head space and dissolved oxygen in the product

Submit Response

17-01790

Industrial

Physical laboratory needed for OSHA testing verify heights and weights/limatations to OSHA 1926.701b Testing U-Posts, T,Posts and Rebar. I would like a test performed dropping a 250lb bag of sand 3',5',8', and 10' also the same using a 200lb bag of sand

Submit Response

17-01784

Industrial

Analytical Chemistry Laboratory needed for MSDS or SDS analysis on a salt water/methanol solution.

Closed

17-01771

Industrial

Industrial Laboratory needed for DIN Testing of Heat Shrink Sleeve as per DIN EN 12068 Stress Class C 60 UV

Closed

17-01765

Industrial

Laboratory needed for polymer testing to OECD guidelines to support regulatory submission including:

111 Hydrolysis as a Function of pH 117 Partition Coefficient (n-octanol/water), High Performance Liquid Chromatography (HPLC) Method 120 Solution/Extraction Behaviour of Polymers in Water

Closed

17-01755

Industrial

ISO 17025 Materials Laboratory needed for ASTM Testing of biodegradable plastic bags to ASTM 6954 Standard Guide for Exposing and Testing Plastics that Degrade in the Environment by a Combination of Oxidation and Biodegradation

Closed

17-01754

Industrial

Materials Laboratory needed for silicon dioxide partials testing.

Closed

17-01744

Industrial

Analytical Chemistry Laboratory needed for the following analyses in cigarette filter material:

Citrate analysis Determination of Diethylene glycol level Determination Of The Total Denier And Crimp Of Cellulose Acetate Tow Used As Filter Material Determination Of Finish Oil Content In Cellulose Acetate Tow By Soxhlet Extraction Determination of glycyrrhizic acid6Determination of glycerine, diacetate, propionate Determination of purity of liquid and/or dry materials Determination of titanium dioxide Determination of Ethanol, 2-Propanol, 1-Propanol, Ethyl Acetate, Isopropyl Acetate, 1-Methoxy-2-Propanol, Propyl Acetate, 1-Ethoxy-2-Propanol, Toluene, Ethyl Benzene, p-Xylene, o-Xylene Determination of Ethanol, Propylene Glycol, Menthol, Benzylic Alcohol And Glycerin In Solutions By Gc Softening Point For Hotmelt Adhesives Ash Tr

Closed

17-01731

Industrial

Occupational Health Laboratory needed toconduct 8-hour exposure monitoring on employees for CO and CO2. Would a five layer gas sampling bag be the best sample media to use, or is there a more appropriate monitoring option?

Closed

17-01726

Industrial

Electrical Certification Laboratory needed for NFPA certification testing of lineman's gloves to NFPA 70E, Standard for Electrical Safety in the Workplace

Closed

17-01724

Industrial

Large Manufacturer need Automotive Laboratory for FMVSS Testing of Step Van to FMVSS 124.Accelerator Control Systems

Closed

17-01721

Industrial

Electrical Laboratory needed for ASTM of gloves as per ATSM D120 Electrical Insulating Gloves including Validation of product to meet the requirements of the standard.

Closed

17-01702

Industrial

LONG-TERM TESTING Large pharmaceutical manufacturer needs Packaging Laboratory to perform a USP container closure study performed to ensure the closure in place to USP <1207> Package Integrity Evaluation - Sterile Products

Closed

17-01701

Industrial

Polymer Laboratory needed for polythene film testing for the presence of Tris Nonylphenyl Phosphate ) & 4-np free (P-nitrophenol) in the polythene film.

Closed

17-01699

Industrial

University Researcher needs mechanical laboratory for temperature measurement for 2 engine pistons with and without coating.

Closed

17-01694

Industrial

Packaging Laboratory needed for child resistant package testing specific to flow-wrapped pouches

Closed

17-01693

Industrial

URGENT / LONG-TERM TESTING Materials Laboratory needed to measure the AR coating on windows and lenses at 1590 and 1877 nm in the 0.05 - 0.2% range by IR Spectrophotometer

Closed

17-01685

Industrial

Electrical Laboratory needed for ASTM Testing of safety protection gloves to ASTM F2675 Standard Test Method for Determining Arc Ratings of Hand Protective Products Developed and Used for Electrical Arc Flash Protection

Closed

17-01681

Industrial

Healthcare manufacturer needs Microbiology Laboratory for Bacterial Suspension Testing using P. aeruginosa. Specifications are: Suspensions diluted to 10^-6 and 10^-7 in sterile saline, pour plated in 0.2 ml amounts in Trypticase Soy Agar and incubated 24-48 hours at 33C to 37C. T0: 4.3 x 10^7 7.6 x 10^8 CFU/ml T6: 4.6 x 10^7 7.6 x 10^8 CFU/ml

Closed

17-01680

Industrial

Power equipment manufacturer needs Analytical Chemistry Laboratory to identify and quantify the species of organic and inorganic content contained in some samples of condensate by Liquid Chromatography Analysis

Closed

17-01668

Industrial

ISO/IEC 17025 Performance Laboratory for gloves testing to standard: ASTM F2961 - 15 Standard Test Method for Characterizing Gripping Performance of Gloves Using a Torque Meter.

Closed

17-01666

Industrial

Materials laboratory needed for measurements on an anti-reflection coating on both external surfaces of a cemented doublet measured. The diameter of the doublet is 110mm, and the focal length 500m. The reflectance of the coatings is specified as < 0.2% at 632.8nm and normal incidence, whereas we measure > 0.4%. I am looking for measurements from an independent laboratory to convince the vendor to take the lens back.

Closed

17-01660

Industrial

Performance laboratory needed tor conducting a study to evaluate the resistance to radiation of a reusable thermal insulation pad. The resistance to radiation is conducted at a cumulative gamma radiation dose of 100 Mrad and evaluated for visible changes to sample after giving dose of 100 Mrad. Please feel free to ask any questions.

Closed

17-01651

Industrial

Pump manufacturer needs industrial laboratory for performance and life testing on submersible pumps.

Closed

17-01633

Industrial

Contract Sterilizer needed for ETO Sterilization

Closed

17-01632

Industrial

FDA registered and cGMP compliant analytical chemistry laboratory needed for latex and/or DEHP (Di Ethyl Hydroxy Phthalate) testing on rubber closures (stoppers) or syringe pistons used for injectable pharmaceuticals. We are not currently looking for a full extractable/leachable study, just the ability to test for the specific items.

Closed

17-01629

Industrial

Materials laboratory needed for ANSI and ASTM testing of liquid membranes to ANSI 118.10, For Load Bearing, Bonded, Waterproof Membranes for Thin-Set Ceramic Tile And Dimension Stone Installation, ANSI 118.12, Crack Isolation Test and ASTM E96-00, Standard Test Methods for Water Vapor Transmission of Materials

Closed

17-01625

Industrial

Materials laboratory needed for weathering and performance testing of coatings to determine which will preserve and protect the outdoor signs from graffiti and the sun the longest, a specific film laminate, or a spray coating such as AkzoNobel Autocoat BT LV650 ANTI-GRAFFITI. We can prepare a sample treated with each and send it to you IF you can test and tell us how long the sample will last outdoors.

Closed

17-01624

Industrial

Materials laboratory needed for optical testing to determine the luminescence and the evenness of the light across a part that is 3±0.5 cd/m^2 and evenness within 13%

Closed

17-01614

Industrial

Laboratory needed for leak detector performance testing to SAE J1627, Performance Criteria for Electronic Refrigerant Leak Detectors

Closed

17-01608

Industrial

Laboratory needed for water treatment equipment testing to NSF/ANSI 419 testing of ultrafiltration membrane module

Closed

17-01591

Industrial

Plastics laboratory needed for gamma ray irradiation and measurement of light transmittance in PET bottles used in food and beverages. For measurement of light transmittance, it must be measured at 540-550nm. CFU should be less than or equal to 10 for mould, yeast and aerobic bacteria. CFU should be less than or equal to 5 for coliform. CFU should be 0 for E. Coli.

Closed

17-01579

Industrial

Large company needs packaging laboratory for lid seam testing on aluminum cans of carbonated beverages such as cola and sparkling to determine the psi at which the seam fails, and a seam breakdown analysis.

Closed

17-01561

Industrial

Electrical laboratory needed for SAE charge accumulation and dissipation testing for rubber hose with flowing fuel substitute fluid according to SAE1645, Fuel Systems and Components - Electrostatic Charge Mitigation

Closed

17-01560

Industrial

Large corporation needs food laboratory needed with a certified sensory expert to run ASTM comparison study on two developmental food packaging systems for taste and odor transfer as per ASTM E1870.

Closed

17-01557

Industrial

Accredited laboratory needed for determining the combined thermal and mechanical stresses on messenger core of ABC cable acc to HD 626-2 subclause 2.3.2 method 2

Closed

17-01551

Industrial

ISO/IEC 17025 Automotive laboratory needed for resin testing to Mercedes Standard DBL 7384:2015: Supply Specification Coating of plastic parts in vehicle interiors including: As specified in Spec per following items: 7.13 Flame retardant properties 7.14 Odor test 7.15 Fogging test 7.15.1 Quantity of condensable substance 7.16 Thermal desorption analysis 7.16.1 VOC value 7.16.2 FOG value 7.17 Hot light aging

Closed

17-01533

Industrial

Large pharma needs packaging laboratory for container closure integrity testing of vials including -Microbial Challenge (liquid immersion) -Dye ingress test -Container Headspace analysis

Closed

17-01521

Industrial

Valve and fitting firm needs service provider for calibration of it's deadweight tester

Closed

17-01519

Industrial

Large Pharma needs polymer laboratory to study and develop new blends of polymers including the characterization (mechanical, physical) of the produced blends and supply of samples.

Closed

17-01511

Industrial

Plastics laboratory needed for ASTM testing to ASTM D6954-04 Standard Guide for Exposing and Testing Plastics that Degrade in the Environment by a Combination of Oxidation and Biodegradation

Closed

17-01510

Industrial

Contract Sterilizer needed for the sterilization of plastic disposable petri dishes as well as specifications for their packaging.

Closed

17-01503

Industrial

Laboratory needs technical service company for Temperature and Humidity Mapping Validation Studies of Stability Chambers and Refrigerator :

30/75 : 5 SHELVES (@5 points per shelf) 40 / 75 : 5 SHELVES (@ 5 Points per shef)

Please quote separate on doing temperature mapping for our fridge aswell .

There are 5 shelves in the fridge, and we need to place 5 data loggers on each shelf.

Please find the photo of the fridge attached.

Submit Response

17-01502

Industrial

DEVELOPMENT Packaging laboratory needed for determining the specific packaging requirements and packaging stability testing for vinegar based syrup. Considerations to determine are if products needs to be vacuum packed, refrigerated before and/or after opening, etc.

Closed

17-01474

Industrial

Pharmaceutical analytical chemistry laboratory needed for United States Pharmacopeia (USP) 27 testing for extractables and light transmission.

Closed

17-01472

Industrial

Accredited automotive laboratory needed for ISO mechanical testing of spark plugs to ISO 11565 - Road vehicles Spark-plugs Test methods and requirements

Closed

17-01468

Industrial

Laboratory needed to measure nicotine captured by (1) passive air filters, and (2) surface dust wipes.Specifically, the air nicotine needs to be analyzed using passively sampled glass fiber filters that are treated with sodium bisulfate.

Closed

17-01463

Industrial

Plastics laboratory needed for ISO biodegradability testing as per ISO 15985, Determination of the ultimate anaerobic biodegradation and disintegration under high-solids anaerobic-digestion conditions Method by analysis of released biogas

Closed

17-01461

Industrial

Materials laboratory needed for ASTM bench mark testing of acrylic caulks. Tests needed include Application Rate v2 ASTM C1183 Boeing Flow ASTM D2202 Tack Free Time (TFT) ASTM C679 Shore A Hardness ASTM D2240 Tensile ASTM D412 Elongation ASTM D412 Modulus @25% ASTM D412 Modulus @50% ASTM D412 Modulus @75% ASTM D412 Modulus @100% ASTM D412 Weight Loss ASTM C1246 Volume Shrinkage ASTM C1241 QUV Chamber ASTM C793

Closed

17-01436

Industrial

Environmental analytical chemistry laboratory needed for VOC testing to EPA Compendium TO-14 Determination Of Volatile Organic Compounds (VOCs) In Ambient Air Using Specially Prepared Canisters With Subsequent Analysis By Gas Chromatography

Closed

17-01434

Industrial

Microbiology laboratory needed for disinfectant efficacy test ingversus Hepatitis B and a test versus Avian influenza

Closed

17-01431

Industrial

Materials laboratory needed for testing depth of impressions on the surface of an embossed nonwoven sheet (approximately 25 samples). using the method Laser Triangulation or Laser Profile Measurement

Closed

17-01421

Industrial

Third-party laboratory needed for testing an Inner Shield Wire (1.2mm diameter) to ASME SFA-5.20 standard, Safety in Welding, Cutting, and Allied Processes

Closed

17-01407

Industrial

Materials laboratory needed for ASTM Testing of plastics to ASTM D2990 Standard Test Methods for Tensile, Compressive, and Flexural Creep and Creep, Rupture of Fiberglass Reinforced Plastics.

Closed

17-01403

Industrial

Performance laboratory needed for ASTM and ISO testing of protective fabric used in coveralls to ASTM F2130, Standard Test Method for Measuring Repellency, Retention, and Penetration of Liquid Pesticide Formulation Through Protective Clothing Materials or iso 22608, Protective clothing Protection against liquid chemicals Measurement of repellency, retention, and penetration of liquid pesticide formulations through protective clothing materials A lab with ISO17491-4 capabilities would be welcomed.

Closed

17-01361

Industrial

Automotive laboratory needed for ANSI testing of glazing materials (glass) to ANSI Z26.1, American National Standard for Safety Glazing Materials for Glazing Motor Vehicles and Motor Vehicle Equipment Operating on Land Highways - Safety Standard

Closed

17-01349

Industrial

Large industrial supplier needs plastics laboratory for roughness testing on rubber sheets.

Closed

17-01347

Industrial

Packaging laboratory needed for comparison evaluation of the strength parameter of corrugated boxes from different suppliers.

Closed

17-01328

Industrial

Plastics laboratory needed for shrink film testing for: puncture thumb edge, puncture sharp edge, tear strength and haze

Closed

17-01316

Industrial

Materials laboratory needed for flammability of industrial, coated textiles to two BS Specifications including: BS 7837:1996,Specification for flammability performance for textiles used in the construction of marquees and similar textile structures BS 5438:1989, Methods of test for flammability of textile fabrics when subjected to a small igniting flame applied to the face or bottom edge of vertically oriented specimens

Closed

17-01311

Industrial

Materials laboratory needed for NFPA testing of goggles to NFPA 1977-11 for Heat and Thermal Shrinkage Resistance for goggles.

Closed

17-01310

Industrial

Polymer laboratory needed for Coefficient of Friction (COF) testing on plastic film samples to ASTM D1894, Standard Test Method for Static and Kinetic Coefficients of Friction of Plastic Film and Sheeting.

Closed

17-01305

Industrial

Materials laboratory needed for chemical analysis of smell during processing of release base paper product. using a silicon.

Closed

17-01303

Industrial

Toxicology laboratory needed for USP biological reactivity testing of rubber and or silicone used in pharmaceutical products to USP 6, Plastics Test

Closed

17-01295

Industrial

Industrial Hygiene Laboratory needed for Vapour Monitor testing (Sampling Badge - 3M) for 30 samples.

Closed

17-01293

Industrial

Materials laboratory needed for reflectivity measurements for Anti-Reflection AR coated glass plates. The glass plates are 4.75 x 3.75 x 0.063 in size.

Closed

17-01284

Industrial

Laboratory needed for ANSI testing a pilot and thermocouple assembly to ensure that it meets ANSI Z21.77 for Piezo-Electric Spark Ignitors and ANSI Z21.92 for Manually Operated Electric Gas Ignition Systems

Closed

17-01273

Industrial

Large consumer products company needs laboratory for ASHRAE compliance testing to ASHRAE 145.2-2011, Laboratory Test Method for Assessing the Performance of Gas-Phase Air Cleaning Systems: Air Cleaning Devices. Laboratory must have the ability to test low concentration formaldehyde challenge in standard.

Closed

17-01265

Industrial

Laboratory needed for VBI filter porosity testing to The Association of German Engineers Standard VDI 3926 PART 1 . 2004 Evaluation of filter media which are used in dry-operating cleanable filters

Closed

17-01244

Industrial

URGENT Packaging laboratory needed for sensory testing on a new food packaging item in order to market it in the EU. Assess whether the packaging when used as intended (to heat food) causes an off odor or taste to the food, rendering the food unfit for use.

Closed

17-01239

Industrial

FDA food packaging laboratory needed for quality control, food grade verification testing of food grade container product that is manufactured for US firm in China. The food container is made of PP and TPE and needs to be testing to ensure it is FDA Food grade and BPA-free.

Closed

17-01232

Industrial

Plastics laboratory needed for ASTM testing of plastic film and sheeting for water vapor using a modulated infrared sensor to ASTM F1249-13 test method for water vapor transmission rate.

Closed

17-01230

Industrial

Metallurgical laboratory needed for failure investigation of a failed metal plug stem that is a part of a Control Valve. It broke during operations, and we would like to have it tested, to see whether it is a manufacturing issue, or much more related to process.

Study required: 1. Ultrasonic test 2. Radiography test 3. Hardness test 4. Tensile test 5. Chemical analysis 6. Fractography test

And any other recommended test?

Kindly advise the procedures, lead time and other related information.

Closed

17-01195

Industrial

Consumer Products Laboratory with ISO 17025 accreditation needed for Consumer Panel testing for child resistant packaging for lighters to 16 CFR 1210

Closed

17-01182

Industrial

Materials laboratory needed for powder coatings testing applied to metal panels. The topography and texture of powder coating surfaces to image and quantify roughness and identify patterns

Closed

17-01177

Industrial

Materials laboratory needed for USDOT certification testing of 30 gal bio boxes for transporting Corrosive Class 8 UN3261 materials.

Closed

17-01172

Industrial

FDA food laboratory needed for FDA food contact material safety testing of plastic resealable containers to show it is BPA free.

Closed

17-01167

Industrial

Polymer laboratory needed for ASTM testing for determination of Carbon Black in vinyl compound to ASTM D3349 , Standard Test Method for Absorption Coefficient of Ethylene Polymer Material Pigmented with Carbon Black

Closed

17-01152

Industrial

Medical Device laboratory needed for ISO pre-compliance filter testing on medical ventilation module in accordance with ISO 23328-1:2008 standard, Breathing system filters for anaesthetic and respiratory use Part 1: Salt test method to assess filtration performance The standard specifies a salt (NaCl) filtration challenge.

Closed

17-01149

Industrial

Environmental toxicology laboratory needed for eco-toxicity testing on a pipe liner to be used in culverts in California.

Closed

17-01145

Industrial

Packaging company needs laboratory for flash point testing for Green Seal Certification.

Closed

17-01143

Industrial

Plastics laboratory needed for acetaldehyde testing for PET bottle preforms by gas chromatography.

Closed

17-01134

Industrial

Polymer laboratory needed for testing water vapors and oxygen gas permeability testing of new improvement in barrier of food packaging films made by blending two polymers.

Submit Response

17-01127

Industrial

Materials laboratory needed for UV resistance testing in HDPE Corrugated Flexible Pipe used as an electrical conduit

Submit Response

17-01126

Industrial

Metallurgical laboratory needed for ASTM testing of copper clad steel wire to two ASTM Standards including:

ASTM B227, Standard Specification for Hard-Drawn Copper-Clad Steel Wire

ASTM 228, Standard Specification for Steel Wire, Music Spring Quality which includes tension, torsion and wrap

Closed

17-01122

Industrial

LONG-TERM TESTING Large corporation needs electrical laboratory for multiple electrical tests on refrigerator system (domestic and commercial).

Closed

17-01114

Industrial

Polymer laboratory needed forGas chromatography mass spectrometry GC-MS analysis to determine the organic purity of 2-Octyl cyanoacrylate monomer using with Agilent 7820A or Shimadzu GC-2010.

Closed

17-01108

Industrial

ISO 17025 metallurgical laboratory needed for ASTM testing of copper tubes (diameter 8mm) to ASTM B577: 2016 - Standard Test Methods for Detection of Cuprous Oxide (Hydrogen Embrittlement Susceptibility) in Copper - Method A (or in according to standard ISO 2626: 1973 - Copper - Hydrogen embrittlement test) on some samples of copper tubes (diameter 8 mm).

Closed

17-01091

Industrial

Construction materials laboratory needed for physical testing of Fiber Reinforced Polymer (FRP) Reinforcing Bar including 160 samples tested for durability in accordance with the following standards:

-AC320 (an acceptance criteria from ICC) -Conditioned for 1000 and 3000 hours using ASTM D 2247 -ASTM C 581 Standard Practice for Testing Water Resistance of Coatings in 100?% Relative Humidity

Closed

17-01075

Industrial

Packaging company needs laboratory for overall migration limit testing on 8 different plastic products including shrink film and PET for the specific limits of heavy metals, primary aromatic amines (PAA), phthalates, bisphenol amine (BPA), and PAN .

Submit Response

17-01070

Industrial

Materials laboratory needed for testing waterproofing membrane for 1 - hydrostatic head resistance (an independent test) required values: 70m (231ft), 2 - wet/dry cycling (an independent test) required values: no effect @ 25 cycles at 231ft, and 3 - adhesion to concrete (an independent test) 4 - technical properties testing per ASTM standards including mass per unit area, peel adhesion to concrete, hydrostatic pressure resistance, permeability, grab tensile strength, puncture resistance, low temperature flexibility, and water vapor transmission rate.

Closed

17-01056

Industrial

Materials laboratory needed for ASTM testing of newmarine coating to ASTM D4939 Subjecting Marine Antifouling Coating to Biofouling and Fluid Shear Forces in Natural Seawater and ASTM D5618 Measurement of Barnacle Adhesion Strength in Shear on materials

Closed

17-01047

Industrial

Packaging laboratory needed to analyze the gas content of a modified atmosphere packaged food product for O2, CO2, and nitrogen gases.

Closed

17-01046

Industrial

Electrical laboratory needed for UL certification testing of centrifuges with two motors prior to shipment to Canada.

Closed

17-01039

Industrial

Construction materials company for agriculture needs polymer laboratory to test content analysis of PVC

Closed

17-01022

Industrial

URGENT TESTING Polymer laboratory needed for certificate of analysis COA testing required on three polymer products used in waste water treatment. Testing results needed by Saturday, June 24.

Closed

17-01017

Industrial

Materials microbiology laboratory needed for preservative effectiveness testing of a coating.

Closed

17-01008

Industrial

Oil laboratory needed for refrigerant systems compressor oil analysis of four mechanical HVAC compressors.

Closed

17-01003

Industrial

Medical Device company needs packaging laboratory for transportation simulation studies of polypropylene and polyethylene medical devices with a shelf life of 5 years.

Closed

17-01001

Industrial

Packaging laboratory needed for ASTM testing of packaging material for cushioning curve of packaging materials by the ASTM D-1596 test method, Dynamic Shock Cushioning Characteristics of Packaging Material. This ASTM test method uses acceleration-time data achieved from dropping a falling guided platen assembly onto a motionless sample.

Closed

17-00995

Industrial

University research scientist needs materials laboratory for thermal conductivity testing of composites across varying temperature ranges.

Closed

17-00991

Industrial

Polymer laboratory needed for Fourier transform infrared spectroscopy (FTIR) analysis on a polypropylene product.

Closed

17-00990

Industrial

Pharmaceutical company needs mechanical laboratory for ISO functionality (force testing) of medical instruments to ISO 11608-1 Testing of auto injectors and stability

Closed

17-00975

Industrial

Petrochemical company needs laboratory for ASTM sand slurry testing for ultra-high-molecular-weight polyethylene UHMWPE per ASTM 4020 Standard Specification for Ultra-High-Molecular-Weight Polyethylene Molding and Extrusion Materials

Closed

17-00970

Industrial

LONG-TERM TESTING Metallurgic laboratory needed for ASTM grain size testing on Ni 200 rolled sheet that has been cold worked in multiple operations to ASTM E112, Standard Test Methods for Determining Average Grain Size. We will require multiple analyses over an extended period of time.

Closed

17-00967

Industrial

Polymer laboratory needed for full polyethylene low-density PE-LD polybag quality testing.

Closed

17-00966

Industrial

New distillery needs laboratory for stability testing of alcoholic beverages in aluminum cans for the integrity of the water-based polymer lining of the can

Closed

17-00960

Industrial

LONG-TERM TESTING Large pharma needs packaging laboratory for child resistance cap testing on a regular basis to industry approved test procedures.

Closed

17-00959

Industrial

Mechanical laboratory needed for ASTM Testing (yield/breaking strength/elongation) of uncoated seven-wire strand (15.24mm) in accordance with ASTM A416 Grade 270.

Closed

17-00951

Industrial

Physical laboratory needed for EN fire safety testing (90min) for storage cabinets as per EN 14470, European Standard for Safety Storage Cabinets

Closed

17-00949

Industrial

Materials laboratory needed for comparison study of the Coefficient of Friction (COF) of two lubrication sticks according to BS EN - Annex L.

Closed

17-00946

Industrial

Airline needs aviation laboratory for MIL-STD testing of aviation oxygen to MIL-PRF-27210 Oxygen Aviator's Breathing Liquid Gas.

Closed

17-00945

Industrial

Packaging laboratory needed for ASTM testing to ASTM C868 Standard Test Method for Chemical Resistance of Protective Linings and ASTM D6677 Standard Test Method for Evaluating Adhesion by Knife

Closed

17-00944

Industrial

Engineering company needs metallurgical laboratory for corrosion investigation of rotating bottle apparatus.

Closed

17-00942

Industrial

Virology laboratory needed for virus transfer study of medical device membrane blood filter.

Closed

17-00940

Industrial

URGENT Large corporation needs automotive laboratory for UN testing of coating tint used on windscreen/windshield to ISO 3537 Headform testing for automotive windscreen/windshield or UNECE R43, Uniform provisions concerning the approval of safety glazing materials and their installation on vehicles

Closed

17-00919

Industrial

Consumer products / textiles laboratory needed for polyester textile fiber testing for silicone composition.

Closed

17-00912

Industrial

Electrical laboratory needed for AITM testing of wires /cables 1) AITM 2.0008A Smoke Density Electrical Wire/Cable for Power Supply, 2) AITM 2.0008B Smoke Density Electrical and Non-Electrical Cable for Signal/Data Transmission, and 3) AITM 3.0005 Smoke Toxicity Flaming

Closed

17-00908

Industrial

LONG-TERM TESTING Physical laboratory needed for ASTM flammability testing of paint to ASTM D822 Open-Flame Carbon-Arc Exposures of Paint and Related Coatings, test to four 4x6 samples.

Closed

17-00907

Industrial

Environmental toxicology laboratory needed for standard LC50 toxicity testing for flathead minnow to comply with MSDS for a plant-derived odor control product used in landfills.

Closed

17-00903

Industrial

URGENT TESTING Performance laboratory needed for ASHRAE testing of air filter to ASHRAE Standard 52.1-1992,Gravimetric and Dust-Spot Procedures for Testing Air Cleaning Devices Used in General Ventilation for Removing Particulate Matter or minimum efficiency rating value (MERV) per ANSI/ASHRAE Standard 52.2-2007, Method of Testing General Ventilation Air Cleaning Devices for Removal Efficiency by Particle Size

Closed

17-00901

Industrial

University research scientist needs materials laboratory for tensile strength analysis of a biocompatible polymer nanocomposite.

Submit Response

17-00892

Industrial

Electrical laboratory needed for IEC testing of transformers to IEC 61869-1, Instrument transformers and IEC 61869-2, Instrument transformers - Part 2: Additional requirements for current transformers

Closed