Top

Incoming Defense Laboratory Test Requests

Contract Laboratory has received the following Defense Laboratory Test Requests which need to be fulfilled! These Laboratory Test Requests are received from a variety of sources ranging from start-up companies to large, multinational Fortune 500 corporations, international organizations, well-respected universities and government agencies that are actively seeking Independent, Third-Party Defense Laboratories to perform their Defense Testing, Analysis, Assays, Product Development, Scientific Research Experiments, Inspections, Certifications, and Engineering Projects. If you are a Defense laboratory that would like more information on these Defense projects, please visit our registration page or call toll us free 1-855-377-6821.

Below are our 50 most recent Defense laboratory test requests. Please log in to see more.

17-00404

Defense

LONG-TERM TESTING Laboratory needed for ongoing and yearly proof testing of various hose assemblies to IAW SAE J2064 using an inert gas and cleanliness testing IAW SAE J2064 testing of various hose assemblies for HVAC units for vehicles.

Closed

17-00164

Defense

Aeronautical laboratory needed for Mil-Spec 25567E testing for liquid leak detection with oxygen and corrosiveness
Product already has 25567C approval

Closed

16-02355

Defense

Europe company needs materials laboratory for specialized military-use tape testing for reflective, effective- fluorescence, yellow color,fire resistant qualities per EN 20471:2013 and EN ISO 14116:2015 standards

Closed

16-02007

Defense

Materials laboratory needed for NATO coatings testing of chemical agent resistant coating (CARC) to North Atlantic Treaty Organization NATO AEP 64 standard fo Performance Requirements for Paint Systems Resistant to Chemical Agents and Decontaminants, for the Protection of Land Military Equipment and 65 coded Standard, described as Performance Requirements and Test Method for Paint Systems Resistant to Chemical Warfare Agents, for new new coating project to:

Screening Test (Resistance to Tri-n-Butyl Phosphate) onAluminium Alloys: 2024-T3 unclad, 5083 and 7020-T8

Optical Characteristics:
*Visual comparison of the colour of the paints
*Specular Gloss
*Colorimetry on Aluminium Alloy 5083 or 7020-T6 and Steel

Scratch Hardness on Aluminium Alloy 5083 or 7020-T6 and Steel

Flexibility (Cupping test) on Aluminium Alloy 5083 or 7020-T6 and Steel

Cross-Cut Resistance (Adhesion) on Aluminium Alloy 5083 or 7020-T6 and Steel

Continuous condensation on Aluminium Alloy 5083 or 7020-T6 and Steel

Hydrocarbons Resistance on Aluminium Alloy 5083 or 7020-T6 and Steel

Acids Resistance on Aluminium Alloy 5083 or 7020-T6 and Steel

Decontaminants Resistance on Aluminium Alloy 5083 or 7020-T6 and Steel

Falling Weight Test Aluminium Alloy 5083 or 7020-T6 and Steel

Chemical Agents Resistance on AEP 65 (Aluminium Alloy 5083 or 7020-T6 or Steel

Artificial Weathering Resistance on Aluminium Alloy 5083 or 7020-T6 and Steel

Corrosion Resistance (Neutral Salt Spray) on Steel

Corrosion Resistance (Cyclic corrosion) on Steel

Aluminium Alloys Corrosion Resistance by Alternate Immersion-Emersion on Burnished Aluminium Alloys: 2024-T3 unclad, 5083 and 7020-T6

Aluminium Alloys Corrosion (Filiform corrosion resistance) on Burnished Aluminium Alloys: 2024-T3 unclad, 5083 and 7020-T6

Hydraulic Fluids Resistance on Aluminium Alloy 5083 or 7020-T6 and Steel

Closed

16-01306

Defense

EPA Microbiology Laboratory needed for EPA microbiology testing. We are looking for EPA testing for heterotrophic plate counts, E. coli and Enterococci (preferably using IDEXX kits), and Vibrio cholerae testing. Samples would be collected from ship ballast water. We would like to specifically get information on labs in or near Vancouver, BC area as we would be shipping samples overnight from the Vancouver area.

Closed

16-01180

Defense

Large organization needs laboratory for conducting testing on contaminated mining waste testing for acid generation potential.

Closed

16-01110

Defense

Materials Laboratory needed for Atomic Absorption analysis for quantification of Ag+ ions released into an aqueous environment. Please provide the cost on a per sample basis.

Closed

16-01028

Defense

Textiles laboratory needed for MIL/BS Fabric Testing required for anti radar on fabric used for camouflage nets as per MIL/BS standards.

Closed

15-02050

Defense

Materials laboratory needed for Fabric Testing required for anti radar on fabric used for camouflage nets as per MIL/BS standards.

Closed

15-01774

Defense

Asia textiles laboratory needed for Fabric Testing required for anti radar on fabric used for camouflage nets as per MIL/BS standards.

Closed

15-00864

Defense

Materials Laboratory needed for ISO Testing of alloys: ISO 2135 Light fastness of aluminum alloys Spec ? ISO 2135
Part is round ( about 21? diameter) ? made of aluminum 2014, weighs around 15 lbs.

Closed

13-00790

Defense

USA analytical chemistry laboratory needed for hydrazine testing for samples of its hydrazine to be analyzed to verify if it has been contaminated or if it can be returned to service.

Closed

13-00240

Defense

US physical laboratory needed for impact sensitivity testing for low explosive material

Closed

12-1310

Defense

Europe DOD ELAP ( Department of Defense Environmental Laboratory Accreditation Program)Accredited environmental laboratory needed for environmental Testing

Closed

12-1097

Defense

Mechanical Laboratory needed for multiple mechanical tests preferablly to be done in turkey by turkey laboratory

Closed

12-0784

Defense

Physical Laboratory needed for age acceleration and abrasion resistence testing of "Cooling, Trauma, Attenuation Vest" to be worn under body armor. We are interested in age acceleration and abrasion resistence of the vest. Please advise time involved and pricing and confirmation of arrangements to pursue the above.

Closed

12-0636

Defense

Eastern USA Analytical Chemistry Laboratory needed for ASTM Testing, ASTM D1500, ASTM D2276 Color and Particulate concentration to be in conformance with AMS2641. 4 Samples to be tested.

Closed

12-0431

Defense

Nuclear Science Laboratory needed for RESIDUAL RADIOACTIVITY LEVEL TESTING OF HOLDERS FROM EACH LOT SHALL BE CERTIFIED TO CONTAIN LESS THAN 1.0 PICOCURIE OF EQUIVALENT STRONTIUM-90 RADIOACTIVITY (AT THE 95% CONFIDENCE LEVEL) WHEN INDIVIDUALLY COUNTED USING A LOW BACKGROUND BETA-PROPORTIONAL COUNTER WHICH HAS BEEN CALIBRATED WITH A STRONTIUM-90 STANDARD".

Closed

11-2543

Defense

Analytical Chemistry Laboratory needed for closed cup flash point testing determination in 1 degree fahrenheit to 300 F range? Its important to measure to 1 degree Fahrenheit.

Closed

11-01052

Defense

USA Electronics Laboratory needed for static breakdown voltage, insulation resistance between terminals, visual & mechanical, parametric defects, and combined catastrophic and parametric defect.

Closed

10-03015

Defense

USA Mechanical Laboratory needed for US Dept of Defense, First Article Test Physical Load Testing-Proof test web sling to withstand static load of 18,750 lbs for 5 min, allow to rest for 24 hrs, then measure to ensure sling returns to original length.

Closed

10-01787

Defense

Southwest Asia Laboratory needed for Shelf life extension testing for petroleum products in accordance to U.S. Department of Defense military specification.

Closed

09-2326

Defense

ISO 17025 Materials Laboratory needed for Optical Distortion, Deviation, Luminous Transmittance, Haze and NVG weighted transmittance. SAmples will need high / low temp, and humidity conditioning.

Closed

09-1164

Defense

Pennsylvania Environmental Laboratory needed for Particle-size analysis of riverbed substrate

Closed

Submit Defense Testing Requests for Defense testing and Defense Scientific Research