Incoming Construction Laboratory Test Requests

Contract Laboratory has received the following Construction Laboratory Test Requests which need to be fulfilled! These Laboratory Test Requests are received from a variety of sources ranging from start-up companies to large, multinational Fortune 500 corporations, international organizations, well-respected universities and government agencies that are actively seeking Independent, Third-Party Construction Laboratories to perform their Construction Testing, Analysis, Assays, Product Development, Scientific Research Experiments, Inspections, Certifications, and Engineering Projects. If you are a Construction laboratory that would like more information on these Construction projects, please visit our registration page or call toll us free 1-855-377-6821.

Below are our 50 most recent Construction laboratory test requests. Please log in to see more.

Test Request 17-01948

Construction

ISO 17025 Laboratory needed for sports floor testing to DIN 18032 SPORTS HALLS - HALLS AND ROOMS FOR SPORTS AND MULTI-PURPOSE USE - PART 1: PLANNING PRINCIPLES

Submit Response

Test Request 17-01889

Construction

Third-Party Laboratory needed for disassembly, examination and testing of headphones for loose staples after consumer report of two staples fell out of a set of headphones . A picture of the staple has been sent to the manufacturer for comment and they have confirmed that staples are not used in the construction of the headphones. We are searching or 3rd party to disassemble the headphones in question and maybe a new set and advise if there are any staples used and/or if a loose staple could become lodged in the headphones and fall out later.

Submit Response

Test Request 17-01849

Construction

Laboratory needed for UL compliance testing of regulators to UL 252.Standard for Compressed Gas Regulator Accessories Inlet pressures up to 110bar

Submit Response

Test Request 17-01833

Construction

Geology Laboratory needed to carry out Saturate, Aromatic, Resin and Asphaltene SARA analysis and ash content on minerals.

Submit Response

Service Request 17-01772

Construction

Laboratory Engineering Company needed for construction and set-up oil testing laboratory for refined petroleum products. The laboratory will carry out testing to confirm they meet specifications before they are received and discharged into storage tanks.

Closed

Test Request 17-01697

Construction

Engineering company needs Materials Laboratory for testing liquid product to ASTM and ANSI Test Standards: who tests ANSI 118.10, For Load Bearing, Bonded, Waterproof Membranes for Thin-Set Ceramic Tile
And Dimension Stone Installation, ANSI 118.12 specifications for crack
isolation membranes for thin-set ceramic
tile and dimension stone installation and ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers?Tension

Submit Response

Test Request 17-01629

Construction

Materials laboratory needed for ANSI and ASTM testing of liquid membranes to ANSI 118.10, For Load Bearing, Bonded, Waterproof Membranes for Thin-Set Ceramic Tile
And Dimension Stone Installation, ANSI 118.12, Crack Isolation Test and ASTM E96-00, Standard Test Methods for Water Vapor Transmission of Materials

Closed

Test Request 17-01584

Construction

Construction laboratory needed for weld failure analysis and root cause analysis of seam failures of Air Supported Structure buildings that are produced using Radio Frequency welding.

A brief background of the situation is this: We use architectural coated fabric for the exterior of the building, typically 30 mil thick, or 28 oz per square yard. The building is designed with a thermal liner of laminated PVC to create a dead-air space between layers for insulation. The thermal liner is 15 oz per square yard. Often a third layer is used to create two dead-air spaces similar to a triple pane window. All layers are welded simultaneously, so in the case of Triple Wall construction there are 6 layers of material being RF welded.

The failures we have experienced occur between the two exterior fabrics, usually during the hottest weather conditions. The weld will open up and appears that the two exterior layers were never fully welded. However, destructive shop tests show that the welds were fully welded.

.My research includes possible tests as final weld thickness, current monitoring, weld temperature monitoring, and others.

Closed

Test Request 17-01545

Construction

INDIVIDUAL Materials laboratory needed for quality and composition testing of pure rock-wool insulation

Closed

Test Request 17-01477

Construction

Laboratory needed for ASTM testing of gypsum as per ASTM C471M - Standard Test Methods for Chemical Analysis of Gypsum and Gypsum Products

Closed

Test Request 17-01440

Construction

NATA accredited construction materials laboratory needed to perform a Flame Index Test to ASTM E84, Standard Test Method for Surface Burning Characteristics of Building Materials

Closed

Test Request 17-01413

Construction

Laboratory needed for FMVSS and ASTM burn resistance testing of safety sheet vinyl flooring in accordance with FMVSS 302 and/or ASTM D5132-04 . The FTT FMVSS 302 is manufactured according to the Federal Motor Vehicle Safety Standard No. 302.

Closed

Test Request 17-01316

Construction

Materials laboratory needed for flammability of industrial, coated textiles to two BS Specifications including: BS 7837:1996,Specification for flammability performance for textiles used in the construction of marquees and similar textile structures BS 5438:1989, Methods of test for flammability of textile fabrics when subjected to a small igniting flame applied to the face or bottom edge of vertically oriented specimens

Closed

Test Request 17-01294

Construction

Laboratory needed for complete failure analysis of bolts that failed ASTM F3125/F3125M-15a, Standard Specification for High Strength Structural Bolts, Steel and Alloy Steel, Heat Treated, 120 ksi (830 MPa) and 150 ksi (1040 MPa) Minimum Tensile Strength, Inch and Metric Dimensions

Closed

Test Request 17-01253

Construction

Construction materials laboratory needed for ASTM testing of Calacatta Marble as per ASTM C 503,Standard Specification for Marble Dimension Stone.

Closed

Test Request 17-01252

Construction

Construction laboratory needed for environmental simulation / accelerated weathering testing of Exterior Grade High Pressure Laminates HPL as per EN-438 part-6, Decorative high-pressure laminates (HPL) sheets based on thermosetting resins. Classification and specifications for exterior-grade compact laminates of thickness 2mm and greater

Closed

Test Request 17-01221

Construction

Metals laboratory needed for destructive testing of stainless steel tie down fixture, two component estimated break of the weakest link 30,000 Lbs. of pull. Multiple testing angles (adjustable base must be designed to support the test). Test device at vertical, 70 degrees from level, and 35 degrees from level.

Closed

Test Request 17-01176

Construction

Construction materials laboratory needed to conduct ASTM and AASHTO testing of asphalt binder to ASTM D2006 Method of Test for Characteristic Groups in Rubber Extender and Processing Oils by the Precipitation Method and AASHTO T 315-12, Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR)

Closed

Test Request 17-01163

Construction

Construction laboratory needed for ASTM testing of floor covering system using radiant heat energy source to 2 ASTM standards

ASTM E 648, Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

ASTM E 662, Standard Test Method for Specific Optical Density of Smoke Generated by Solid Materials

Closed

Test Request 17-01141

Construction

Construction materials laboratory needed for vinyl flooring testing to ANSI/ESD STM 7.1 Standard Test Method for the Protection of Electrostatic Discharge Susceptible Items on 3 vinyl floor covering products

Closed

Test Request 17-01136

Construction

Construction laboratory needed to examine the bonding performance of an adhesive and PVC flooring product combination.

Closed

Test Request 17-01091

Construction

Construction materials laboratory needed for physical testing of Fiber Reinforced Polymer (FRP) Reinforcing Bar including 160 samples tested for durability in accordance with the following standards:

-AC320 (an acceptance criteria from ICC)
-Conditioned for 1000 and 3000 hours using ASTM D 2247
-ASTM C 581 Standard Practice for Testing Water Resistance of Coatings in 100?% Relative Humidity

Closed

Test Request 17-01068

Construction

Hardscape company needs geology laboratory needed for testing rock used for housing yards and roads to confirm absence of harmful materials.

Closed

Test Request 17-01044

Construction

Construction materials laboratory needed for properties testing of a resin/cement blend for oilfield use including compressive strength (MPa), flexural strength (MPa), E-modulus / elasticity (MPa), rupture elongation (%), tensile strength (MPa), and failure flexural strain (%)

Closed

Test Request 17-01039

Construction

Construction materials company for agriculture needs polymer laboratory to test content analysis of PVC

Closed

Test Request 17-01011

Construction

URGENT Physical laboratory needed for ASTM composite testing to test method of ASTM E 756: Vibration Dampening Testing

The testing sample will be a 2-4 mm thick non-ferrous metal composite material.

Closed

Test Request 17-00923

Construction

University researcher needs acoustics laboratory for sound absorptivity testing and thermal conductivity testing of a composite material.

Closed

Test Request 17-00922

Construction

Building company needs construction materials laboratory for waterproof / resistance testing on windows.

Closed

Test Request 17-00856

Construction

Materials laboratory needed for integrity / life expectancy testing of PVDF and Tedlar used in Supported Structure industry and Fabric Structure industry. The textiles are used in products that have a life expectancy of 20 years and need weathering verification over time that the textiles hold up to the elements like sun, rain, etc.

Closed

Test Request 17-00855

Construction

Materials laboratory needed for confirmatory testing of jointing materials for sewer drains to DIN 4062, Cold processable plastic jointing materials for sewerdrains - Jointing materials for prefabricated parts of concrete, requirements, testing and processing

Closed

Test Request 17-00852

Construction

Materials certification laboratory needed for thermal conductivity testing of lightweight concrete to ASTM C177 Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus at 200 - 300 Celcius

Closed

Test Request 17-00831

Construction

Laboratory needed for UL fire testing of solar panels to UL 1703 Standard for Flat-Plate Photovoltaic Modules and Panels.

Closed

Test Request 17-00800

Construction

Large corporation needs materials laboratory for ASTM slip resistance testing of polymer and acrylic prototype bathroom tiles to ASTM 462, Standard Consumer Safety Specification for Slip-Resistant Bathing Facilities

Closed

Test Request 17-00790

Construction

URGENT TESTING Laboratory needed for corrosion testing of metals to ISO 6509 on faucet shanks. ISO 6509-2:2017 specifies assessment criteria and provides guidance related to the corrosion type dezincification for the selection of copper alloys with a mass fraction of zinc >15 %, exposed to fresh, saline, or drinking water. The assessment criteria are based on the exposure tests detailed in ISO 6509

Closed

Test Request 17-00789

Construction

Materials laboratory needed for ASTM thermal conductivity testing of plastic roofing product to ASTM C518 (Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus test) .

Closed

Test Request 17-00761

Construction

Construction materials laboratory needed for plastIcs testing for identification of additives in plastic pipes

Closed

Test Request 17-00749

Construction

Construction materials laboratory needed for ASTM testing of flooring to ASTM E1007: Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures.

Closed

Test Request 17-00747

Construction

Product safety laboratory needed for ANSI testing of ladder levelers to ANSI 14.8-2013 (Safety Requirements for Ladder Accessories).

Closed

Test Request 17-00742

Construction

Plastics construction materials company needs laboratory for Solar Reflectance Index SRI measurement for LEED compliance to ASTM E1980

Closed

Test Request 17-00698

Construction

Construction laboratory needed for materials and toxicity testing of naval thermal insulation testing to various standards including: NCD 1427 : SPECIFICATION FOR MINERAL WOOL MARINE BOARD FOR THERMAL AND ACOUSTIC INSULATION ON BOARD INDIAN NAVAL SHIPS

NCD 1433 : SPECIFICATIONS FOR ELASTOMERIC NITRILE THERMAL INSULATION FOR USE ONBOARD INDIAN NAVAL SHIPS

Closed

Test Request 17-00690

Construction

Materials laboratory needed for ASTM testing for thermal conductivity of nitrile rubber Insulation foam at 0, 20, and 40 Celcius to ASTM C 518 and ASTM C 177 test methods

Closed

Test Request 17-00668

Construction

Construction materials laboratory needed for bisphenol BPA testing in polypropylene sheets

Submit Response

Test Request 17-00626

Construction

Large electronics company needs product safety laboratory for fall hazard, structural integrity / physical stability / product safety testing of a commercial product to ensure it does not present "fall" or "tilt" hazard.

Closed

Test Request 17-00599

Construction

LEGAL Materials laboratory needed for performance, weathering and failure investigation testing of potentially defective, two coat, acrylic elastomeric liquid coating used for roofing on commercial building. Polymer coating that instead of coating and drying within two hours discharged into storm drain causing notification of Fire department and Hazardous Materials units.

Closed

Test Request 17-00555

Construction

Environmental analytical chemistry laboratory needed for ISO & ASTM VOC emissions testing of window coating product to ASTM D5116 and ISO 16000-6 standards.

Closed

Test Request 17-00477

Construction

Engineering company needs materials laboratory for environmental simulations testing of GRP (Glass-Fibre Reinforced Plastic) ground anchor for UV stability testing in accordance with ES ISO 4892-2 , performance at elevated temperatures is in accordance with ACI440.3R-04 Section B.6 Accelerated test method for alkali resistance of GRP bars, and suitability, Durability,

Closed

Test Request 17-00470

Construction

Construction laboratory needed for core testing of concrete samples

Closed

Test Request 17-00455

Construction

Metallurgical laboratory needed for micro structure study of differing layers of zinc on zinc-coated reinforced bars (re bars).

Closed

Test Request 17-00454

Construction

India Engineering / Contstruction laboratory needed for Rock Bolt Anchor Pull Testing on site in Mumbai.

Closed

Test Request 17-00405

Construction

Construction Materials Laboratory needed for strength and durability check of glass reinforced fiber GRF material.

Closed

Test Request 17-00362

Construction

Water agency needs Metallurgical Laboratory needed for corrosion testing including pitting depth from corrosion on 1 Type K Soft copper tubing.

Closed

Submit Construction Testing Requests for Construction testing and Construction Scientific Research