Laboratory Test Request

ASHRAE Refrigeration Oils Testing

Project Description

Large Corporation needs Third-Party Laboratory for ASHRAE Testing of refrigeration oils for sealed glass tube test as per latest ASHRAE-97 test procedure.
1. Refrigeration oil -57
2. Servofriz N57
3. Servofriz 57Plus
The testing has to be carried out at 200 degree cent for 14 days and observations after 14 days with R22 refrigerant. The test parameters are
1. ASHRAE 97-2007/ latest ASHRAE method.
2. All test parameters should be evaluated after 14 days of exposure at 200 degree cent.
3. Pre / Post analysis of oil for TAN, Moisture , ICP analysis .
4. Photographs of before and after exposure .
5. Percentage formation of other refrigerants after 14 days exposure at 200 degree cent.
5. Sample preparation before testing: Please insure that
samples should have less than 35ppm moisture before charging
refrigeration oil in sealed glass tube, if during
transportation/handling it is higher than remove extra moisture by
vacuum/Fuller earth treatment and filtration or any other suitable
technique.
6. Separate test report for each refrigeration oil tested as per ASHRAE97.

Please provide Quotation.


Project Information

Number:18-01118

Industry:Oil and Petroleum

This request is closed and is no longer accepting quotes. Register or Log In to receive alerts when similar requests open in the future.
Oil and Petroleum,Refrigeration Oil,

Test Request: 25-00943

MULTIPLE SAMPLES

BUDGET APPROVED ($2,000-$5,000)

LONG TERM

Need a US testing facility to run simula... view


Test Request: 25-00818

Seeking a laboratory for the electrical characterization of a fluid dielectric. No relation to any compliance standards,... view


Test Request: 25-00763

We need Bombardier’s BAMS 569-001 testing on one of our metalworking fluids. Please share a quote. view