Laboratory Test Request

Project Description

FDA/ GLP microbiology laboratory needed for Disinfectant efficacy testing for Sporicidal Activity of Disinfectant

1.Reuse Stressing of Disinfectant
- 24 hours, followed by
2.Sporicidal Activity of stressed Disinfectants
3. Time course with 3 contact times
4. T= 19 ± 1°C
5. Use Clostridium sporogenes
6. Porcelain penicylinders
7. No soil load
8. 30 carriers
9. Reused stressed product is prepared by diluting substance in filter sterilized distilled water. The diluted substance is then subjected to simulated use and bio-burden stressing followed by sporicidal testing after 24 hours.

Non-GLP Study Report Required for initial study, which may lead to a GLP Study Report

Project Information

Number:07-0764

This request is closed and is no longer accepting quotes. Register or Log In to receive alerts when similar requests open in the future.