Laboratory Test Request

Project Description

Oil Laboratory needed for Automatic Transmission Fluid (ATF) testing: oil side thermal cycle test per the below on 3 or up to 6 units (1/2" NPT connections) . An additional TOC flow loop will need to be present to allow for the TBV wax valve actuation throughout the testing and with differential pressure transducer(max 30 psi) to monitor.
Test set up flow schematic will be provided.

Part #1
0) Oil type (ATF): ATF+4
1) Mounting: No mounting will be required, but additional flow loop will need to be installed into the TOC flow ports
2) Physical set up : See flow schematic,
3) Min temperature (°C); 23.9 C
4) Max temperature (°C): 135.5 C
5) Cycle Time-Total (s): 20 cycles / hour (180 seconds per cycle)
6) Cycle Time Portion Hot/Cold/(s): 90s/90s
7) Initial ramp rate (°C/s): Not Specified, generally linearly rising
8) Min hold time 60 (sec) after outlet >130.5 (°C) and cold <28.9C for 60s
9) Inlet pressure Max or Range (kPa gage); Not controlled
10) Flow Range (lpm): 9.5 LPM (keep min flow >7.6 lpm)
11) Required # of cycles: 1,500 cycles

Part #2: Oil type (ATF): ATF+4
1) Mounting: No mounting will be required, but additional flow loop will need to be installed into the TOC flow ports
2) Physical set up : See flow schematic
3) Min temperature (°C); 23.9 C
4) Max temperature (°C): 79.4 C
5) Cycle Time-Total (s): 30 cycles / hour (120 seconds per cycle)
6) Cycle Time Portion Hot/Cold/(s): 60 sec/60 sec
7) Initial ramp rate (°C/s): Not specified, generally linearly rising.
8) Min hold time 40 (sec) after outlet >75 (°C)
9) Inlet pressure Max or Range (kPa gage); Not controlled
10) Flow Range (lpm): 9.5 LPM +/- 1.9 lpm: (keep min flow >7.6 lpm)
11) Required # of cycles: 3,500 cycles

Pressure Transducer sampling frequency: Nominal 1Hz
Inspect for pressure drop change of more than 10% 2 times daily, notify requestor

Project Information

Number:15-00859

This request is closed and is no longer accepting quotes. Register or Log In to receive alerts when similar requests open in the future.
Oil and Petroleum

Test Request: 25-00944

MULTIPLE SAMPLES

I grow and use mushrooms and would like to get my products tested for psilocybin content by a ... view


Test Request: 25-00943

MULTIPLE SAMPLES

BUDGET APPROVED ($2,000-$5,000)

LONG TERM

Need a US testing facility to run simula... view


Test Request: 25-00942

Looking for testing peptides for mass and purity by a USA laboratory. view