Project Description
Materials Laboratory needed for film testing to ISO 4892-2 Part 2 Method B Cycle 5
Material: PET and Polycarbonate films, which are electrically conductive, laminated to glass
We have 30 films that are 2x2" in size
Total time is 20 days exposure
We need the samples to be taken out and measured for its electrical resistance at time points Day 0, 1, 3, 6, 10, 20. We need electrical resistance using a normal Ohm-meter (2 point probe)
All samples return to chamber. Samples that may have infinite resistance (failure) can be taken out of the test and sent back. At the end return all to Innova.
Can you provide failure analysis services? We would want EDS and SEM done on the samples to see if sulfidation, halogenation, and oxidation occurred to the silver-films.
Project Information
Number:14-00919