Large Oil Compay needs Materials Laboratory for ANSI / SF Testing 4 samples
Water filtration sump to be tested per the ANSI/NSF 42-2000 standard. Section 6.6.6.3 cyclic pressure. The system shall be tested with the outlet plugged after it has been purged of ail. The water temperature shall be 20 C +/- 3C (68 F +/- 5F). The cycle time between the low and high pressure shall be no less than 1 second.section 6.6.1.2 Systems shall be watertight when tested in accordance with 6.6.6.3 after completion of 100,000 cycles at a pressure of 0 to 1040 kPa (0 to 150 psig)