Laboratory Test Request

Multiple Transceivers Testing

Project Description

MULTIPLE TESTING
Transceivers Company needs Laboratory for multiple physical, mechanical , explosives, vibration, fungal resistance, solvents resistance to the following standards:
1. Mechanical Shock
MIL-STD-202H, Method 213, Test Condition I (100 g, 6 ms, terminal-peak sawtooth)

2. Acoustic noise
MIL-STD-810H, Method 515, Procedure I a - Uniform Intensity Acoustic Noise
High performance aircraft at location not close to jet exhausts, 145 dB OASPL with the transmission loss

3. Pressure altitude test
MIL-STD-202-105
altitudes from -1,300 feet to 65,000 feet, over the temperature range -40~+850C

4. Explosive atmosphere test
MIL-STD-810G, Method 511, Procedure I
850C bias on twice

5. Fungus resistance.
MIL-STD-810G, Method 508.
guide for selecting insert materials MIL-HDBK 454, Guideline 4


6. Constant Acceleration
MIL-STD-883, Method 2001
Operating: ±9g in x, y,z direction
Non-Operating:±12g in x, y,z direction

7. Sinusoidal vibration
determine the four (4) frequencies in the range of 40 Hz to 250 Hz to which the equipment is most sensitive
Sine tones of 20 g amplitude, three (3) orthogonal axes

8. Random vibration
MIL-STD-810H, Method 514, Procedure I

9. Fluid resistance
MIL-STD-810, Method 504, Procedure II.
PAO (polyalphaolefin) (MIL-PRF-87252).

10. Resistance to Solvents
MIL-STD-883, Method 2015 or MIL-STD-202-215

Project Information

Number:23-00222

Industry:Transformers, Transmitters, and Transducers

This request is closed and is no longer accepting quotes. Register or Log In to receive alerts when similar requests open in the future.
Electric Circuits,Electric Control Equipment,Electronic Components and Accessories,Electronics,Electrotechnical Products,Transformers, Transmitters, and Transducers,

Test Request: 24-02308

MULTIPLE TESTING

Large sustainable energy company needs transformer cables testing - especially twin enamel epo... view


Test Request: 23-02981

Electronics Laboratory needed for failure root cause analysis testing of current transformer that is not working. view


Test Request: 23-02278

MULTIPLE TESTING USA Medical Device Laboratory needed for AAMI and IEC testing of disposable transducer to AAMI BP22?19... view