Laboratory Test Request

Ford Sensor Testing

Project Description

MULTIPLE TESTING
Environmental Simulation Laboratory for the following Ford Sensors Testing:
2 test required:

1. Salt spray, FORD CETP 00.00-L-467 --- 20pzs
2. Pressure, Temperature and vibration cycling ---- 20pzs
*****Salt spray test******

1. Measure the impedance of each of the sensors according to the settings in the table below.
2. Connect harnesses, tubing and caps and place sensors vertically inside the Spray Chamber.
3. Test for 12 weeks, according to standard CETP 00.00-L-467.
4. At the end of the test, open the chamber and let it rest at room temperature for 48 hours.
5. Visually confirm that there is no intrusion of liquid and salts inside the connector and harnesses.
6. Take a photograph of the before (chamber-mounted sensors) and after each of the sensors.
7. Carry out the Impedance measurement again once the Salt spray test is finished, according to the table below. (There should be no impedance changes greater than 10% vs. initial condition)



******Pressure, Temperature and vibration cycling******


1. Connect DUTs to manifolds and harnesses as shown in the image below. Take t photos of the equipment used and set up. Use a thermocouple to monitor the chamber temperature.
2. Use the test profile shown in the table below. Repeat 14 times.
3. Use Mobil Gargoyle Artic Oil 155 (part number 9985257) and mix with 1% fluorescent liquid.
4. Monitor for liquid leaks under UV light.


Project Information

Number:22-00046

Industry:Automotive and Vehicles

This request is closed and is no longer accepting quotes. Register or Log In to receive alerts when similar requests open in the future.
Sensors,Sensors (Pressure),Sensors (Temperature),Automotive and Vehicles,Automotive Parts,

Test Request: 25-00814

MULTIPLE SAMPLES

Need testing for CARC (Chemical Agent Resistant Coating) as per AEP-65 under STANAG 4360 for ... view


Test Request: 25-00793

We’ve designed a new tow hitch for vehicles that needs to be tested to SAE J684 for regulatory compliance. Looking ... view


Test Request: 25-00741

LONG TERM

Would like to produce and test a patent-pending anti-slip formula with nanoparticles that reduces t... view