Top

Welcome!

NEED A LABORATORY?

Save time and money searching! Find a Lab for all your laboratory testing and scientific research.

Submit Laboratory Test Request

ARE YOU A LABORATORY?

Gain new business by registering your laboratory.

Register Laboratories

HAVE QUESTIONS?

Call us 24/7 1-855-377-6821 or send us an email.

Incoming Automotives Laboratory Test Requests

Contract Laboratory has received the following Automotives Laboratory Test Requests which need to be fulfilled! These Laboratory Test Requests are received from a variety of sources ranging from start-up companies to large, multinational Fortune 500 corporations, international organizations, well-respected universities and government agencies that are actively seeking Independent, Third-Party Automotives Laboratories to perform their Automotives Testing, Analysis, Assays, Product Development, Scientific Research Experiments, Inspections, Certifications, and Engineering Projects. If you are a Automotives laboratory that would like more information on these Automotives projects, please visit our registration page or call toll us free 1-855-377-6821.

Below are our 25 most recent Automotives laboratory test requests. Please log in to see more.

10-02562

Automotives

South Africa Automotive Materials Laboratory needed to conduct a fogging test for DIN 75201 according to Method A (Reflectance %) & Method B (Fravimetric fogging Mass depositing mg)

Closed

10-02548

Automotives

Leading manufacturer of Road Speed Limiter (Autograde) Devices for automobiles needs Mechanical/ Materials Automotive Laboratory for the following testing as per AIS 018(ARAI):
1. Endurance test (at ambient temp.)
2. Endurance test (at high temp.)
3. Endurance test (at low temp.)
4. Endurance test with damp heat cycling.
5. Rapid change of temp test.
6. Endurance test under vibration.
7. Endurance test with salt spray.
8. Conditioning with dust.
9. Conditioning with contaminants.
10. Conditioning with water spray.
11. Drop & Topple test.

Closed

10-02544

Automotives

Toronto GMP, UKAS Mechanical Laboratory needed for ASTM Testing, Mechanical friction testing of a nanotech engine lubricant composition within an engine.

Closed

10-02415

Automotives

Global Trading Company from Myanmar needs Automotives Materials Laboratory to test Auto Spare Parts.

Closed

10-02413

Automotives

Europe ISO Analytical Chemistry Laboratory needed for testing PAH content in Tires using ISO 21461 in accordance to REACH Guidelines.

Closed

10-02390

Automotives

Toronto Canada Mechanical Laboratory needed for testing broken Shaft adapter, probably due to rotational bending fatigue. 3-4 samples available, one failed, 2-3 control samples; samples look like different thermal treatment was performed; steel was quoted to be SCM440; need to find out if different material was used maybe hardness and strength

Closed

10-02277

Automotives

SAUDI ARABIA AUTOMOTIVES TESTING LABORATORY NEEDED TO CONDUCT TESTING FOR KIA NEW MODEL VEHICLES.

Closed

10-02181

Automotives

SAE Laboratory needed for fog testing four small plaques to SAE J1756 using gravimetric procedure. These parts will be adjacent to windows in a truck. Please provide quotation first.

Closed

10-02141

Automotives

SAE Laboratory needed to test 16 samples from two suppliers of 1/2-20 wheel studs to the SAE J2316 standard. Section 4.3 - 16 samples
Section 4.4 - 16 samples
Note: The threaded portion of the wheel stud is 1.0in.

We may be interested sending more samples for loss in tension over time.

Closed

10-02127

Automotives

India Metallurgical Laboratory needed to test Iron ore lumps samples.

Closed

10-02077

Automotives

ASTM Packaging/Mechanical Laboratory needed for the following testing:
SEQUENCE: 1 ELEMENT: A Manual Handling Distribution Simulation Hazards incurred during manual handling such as loading, unloading, dropping, throwing, stacking, sorting or palletizing. DESIGN TESTING PRACTICE FORM Delphi Electronics & Safety PKG WI FOR 651.01.02A Effective Date: March 12, 2006 2 Test Standard- ASTM D4169 (latest revision) Equipment - Lansmont drop tester model PDT-56E Conditioning - ambient Drop Height - 21 inches Drop Sequence - bottom, bottom edge, adjacent bottom edge, bottom corner, diagonally opposite corner Results:
SEQUENCE: 2 ELEMENT: D Vehicle Stacking Distribution Simulation Compressive loads that occur during vehicle transport or warehousing. Test Standard- ASTM D4169 (latest revision) Equipment -Lansmont model 76--5K compression test system. Conditioning - ambient Load applied -L=M x J (H-h / h) x F Where: L=minimum required load, lbf or N, M=mass of one shipping unit or individual container, lbf or N, J=1 lbf/lb or 9.8 m/(s squared) H=maximum height of stack in transit vehicle, in. or m, h= height of shipping unit or individual container, in. or m, and F= a factor (8.0) to account for the combined effect of the individual factors described above. Note: Applicable for expendable containers only. Note NOT APPLICABLE - RETURNABLE if appropriate. Results:
SEQUENCE: 3 ELEMENT: F Loose Load Vibration Random Vibration Test: ASTM D4728 Distribution Simulation Repetitive shocks encountered in the transportation of bulk or loose loads. Test Standard - ASTM D4169 (latest revision) Equipment - MTS vibration system Conditioning - ambient Test Duration - 30 minutes in the normal shipping orientation and remaining 30 minutes split among all other possible shipping orientations (specify orientation in the Results area). Results:

Closed

10-01912

Automotives

India Mechanical Laboratory needed for durability testing: Durabilty Test of hanger
Sine wave test frq.- 20+/-5 Hz
Test Dir.- Z-direction
Apply Load - +/- 75N

2. Durability testing of pipe
Sine wave test frq.- 20+/-5 Hz
Test Dir.- Z-direction
Apply Load - 58.6 Nm

Closed

10-01883

Automotives

Laboratory needed for automotive testing in accordance to VW50185; PV3929; PV3930

Closed

10-01808

Automotives

Asia Laboratory needed for Product Safety Testing in accordance to FMVSS Std. J1571, J1573: one unit of sample to go through the crash test for 4x4 pick up.
Rear Step bumper for pick up.

Closed

10-01788

Automotives

ANSI Laboratory needed for testing in accordance to ANSI Z26.1 Automotive Glazing
Plastic Transparent Nylon
2 thicknesses 0.1" to 0.236"
Item 6 testing
Test 2 Light transmission
Test 16 weathering
Test 19 chemical
Test 29 chemical
Test 22 Flex
Teest 23 flammability

Closed

10-01738

Automotives

ANSI Laboratory needed for testing the following as per Per ANSI NGV 2-2007:
Ambient Cycling Test
Extreme Temp Cycling
Hydrostatic Burst Test
Composite Flaw Tolerance Test
Drop Test
Bonfire Test
Accelerated Stress Test
Penetration Test
Permeation Test
Natural Gas Cycling Test
Leak Before Break

Closed

10-01722

Automotives

Canada Mechanical Laboratory needed for Pressure Cycling & Thermal test to be done on a charge air cooler, destined for truck engine in accordance to ASTM.
2 parts to be submitted.

Closed

10-01602

Automotives

Analytical Chemistry Laboratory needed to test a set of test specimens in accordance to ASTM D 1384.

Closed

10-01577

Automotives

Electrical Laboratory needed for an expert critique for a certain spark plug which will require testing.

Closed

10-01521

Automotives

Midwest USA Materials Laboratory needed to compare the physical, analytical, and performance characteristics of aerosol brake cleaners.

Closed

10-01509

Automotives

USA ANALYTICAL CHEMISTRY LABORATORY NEEDED TO ANALYZE ENGINE OIL.TEST MOTOR OIL FOR CHEMICAL BREAKDOWN & COMPOSITION. ANALYZE FOR POSSIBLE CONTAMINATION.

Closed

10-01391

Automotives

USA NES LABORATORY NEEDED TO TEST ONE STYLE OF AUTOMOTIVE CARPET FOR CONSTRUCTION REQUIREMENTS ONLY - NO COLOR REQUIREMENTS - USING A SPECIFIC TEST METHOD NES MOO76 SUPPLIED BY THE AUTOMOTIVE MANUFACTURER

Closed

10-00845

Automotives

EPA laboratory to conduct emission tests according to EPA regulations for a motorcycle. Requester a certification company from China.

Closed

09-1891

Automotives

North America OECD 301C or ASTM E1720 Environmental Laboratory needed for biodegradability testing.

Closed

08-1762

Automotives

India materials laboratory needed for plastics and polymer testing mainly used in automotives,irrigation projects"

Closed

03-0034

Automotives

Canada Consumer Product Safety Textiles laboratory needed for DIN4102(B1) certification in Canada or near by.

Closed

03-0033

Automotives

Heavy metals testing and FDA extraction testing on printed & folded coupons. (USA)

Closed

03-0032

Automotives

USA toxicology Laboratory needed for skin irritation/sensitisation testing to ISO 10993-10 on polythene film samples. (UK)

Closed

03-0031

Automotives

Pharmaceutical Laboratory needed for Residual Moisture Content analysis (e.g. Karl-Fisher analysis ) on lyophilized cake. All excipients in the formulation safely handled under BL 1 conditions. Fast Turn Around Times a must. Laboratory should be in the contiguous United States.

Closed

03-0030

Automotives

Pharmaceutical Laboratory needed for Osmolality measurements on reconsituted lyophilized formulation. All excipients in the formulation safely handled under BL 1 conditions. Fast Turn Around Times a must. Laboratory should be in the contiguous United States.

Closed

03-0028

Automotives

Bioanalytical Laboratory needed for Vitamin detection on Fetal Bovine Serum. Following is a list of vitamins and detectable units:
Vitamin B-12 pg/mL
Folic Acid ng/mL
Vitamin B-6 ng/mL
Thiamin B-1 ng/mL
Niacin ug/mL
Vitamin H Biotin pg/mL
Riboflavin B2 ng/mL
Vitamin A Retinol ng/mL
Vitamin C ng/mL
A-Tocopherol ug/mL
Carotene ug/mL

Closed

03-0027

Automotives

ENvironmental microbiology laboratory needed for environmental mold issues

Closed

03-0025

Automotives

Microbiology Laboratory needed for Minimum Inhibitory concentration (MIC) determination ,using dilution method

Closed

03-0024

Automotives

Microbiology Laboratory needed for disinfectant efficacy testing

Closed

03-0023

Automotives

EPA GLP certified ENvironmental Laboratory needed that is familiar with EPA tests in LA county

Closed

03-0021

Automotives

ISO Toxicology laboratory needed for In-vitro Toxicology Studies: Cyto-toxicity test to ISO 10993-5

Closed

03-0020

Automotives

Preclinical Laboratory needed for antiviral assay on coronaviruses using our pharmaceutical product(s)

Closed

03-0018

Automotives

Contract Service Preclinical Laboratory to perform an IND enabling FDA GLP toxicology study

Closed

03-0017

Automotives

Consumer Testing for identity testing of capsules

Closed

03-0016

Automotives

Preclinical Contract Research Organization needed for Periodic platelet testing in rats

Closed

03-0015

Automotives

Clinical Contract Research Organization needed for clinical blood testing of rifampin levels in pediatric patients' blood

Closed

03-0012

Automotives

Microbiology Laboratory needed for microbial analysis SB 3112. The test material consisted of only the bacterial spores at a count of 55 x 107 cfu/ml. The tests were run in compliance with the following protocols: 1 USEPA FIFRA;GLP Standards 40 CFR 160 2 USEPA TSCA 40 CFR 792 3 Org. Economic Coop. and Dev. Principles of GLP, Annex 2, C(97)186 4 Japan Ministry of Ag, Forestry & Fisheries, Notification No. 59 Noshan 3850, Director-General of Agricultural Prod. Bureau, 10 Aug 84

Closed

03-0011

Automotives

Analytical Chemistry Laboratory needed for solvent gas chromatography testing of three solvent samples for assay analysis on GC ASAP. Product is very pure ethly lactate.

Closed

03-0010

Automotives

FDA Extraction Test on furnished litho printed coupon paper. Also to do heavy metals testing onfurnished litho inks

Closed

03-0009

Automotives

bioanalytical laboratory needed for bioanalytical testing done on a drug call serostim (hgh)

Closed

03-0007

Automotives

Preclinical toxicology laboratory needed for Cytotoxicity studies: MEM Elution Sample Amount: 120 cm2 or 4 grams Irritation: Intracutaneous Reactivity (ISO) (w/2 extracts) Sample Amount: 240 cm2 or 8 grams Sensitization: Magnusson-Kligman (w/2 extracts) Sample Amount 600 cm2 or 32 grams (6 samples minimum) Sensitization: Local Lymph Node Assay: Sample Amount 400 cm2 or 20 grams

Closed

03-0006

Automotives

Micrbiology Laboratory needed for Microbial Barrier Properties Analysis on Packaging Material

Closed

03-0005

Automotives

Dietary SUpplement Mfg needs FDA analytical chemistry laboratory that can extract herbs supplied by my company of up to 25 times concentration (25:1)

Closed

03-0004

Automotives

University needs Wisconsin Microbiology laboratory TOC (Total Organic Carbon) testing for water analysis on water samples

Closed

03-0002

Automotives

Microbiology Laboratory needed for Microbiology Analysis (Total Plate Count, Yeast, Mold, E. Coli, Salmonella) for 78 Raw Materials

Closed

Submit Automotives Testing Requests for Automotives testing and Automotives Scientific Research