Standards / Methodologies:

Testing Chemical, Biological, Radiological, Mechanical & Electrical
CalibrationThermal Metrology (Contact & Non-contact Measurement, Fixed Points, SPRTs, SSPRTs, RTDs, LIGT, TC, IR-Thermometry & Thermo-hygrometry), Mechanical Metrology (Mass, Volume, Density, Viscosity,  Pressure, Acceleration, Speed and Flow), Dimensional Metrology, Electro-technical Metrology (AC/DC Voltage, Resistance, Current and Frequency, Power, Capacitance, Energy, Time), Fluid-Flow Metrology (Air Velocity, Air Flow Rate) and Calibration of Medical Devices
Proficiency Testing Provider: Testing: Chemical, Biological & Radiological, Calibration: Mechanical, Thermal & Electro-Technical 
Inspection Body: IAF-03: Cereal and Cereal Products, Edible Oils & Seeds, Tea, Coffee, Sugar, Spices & Spice Products, IAF 30: Process Inspection of Food Business Operators, Food Safety Audits, HRAA
Techniques/Methodology: LC/EA-IRMS, LC-MS/MS, LC-ICP-MS, ICP-OES, GC-MS/MS(Dioxins), GC-MS/MS-HS Purge &Trap , GC with ECD, NPD, TCD &FID Detectors , UHPLC with ELSD &UV , Dietary Fiber &Crude Fiber Analyzer , Soxhlet , HPLC with UV, FLD & RI Detectors, HPTLC, lon Chromatograph, AAS with Flame, Graphite  & Hydride Generator , Flame Photometer , Falling No., TOC Analyzer, Particle Counter, Tergotometer, UV Visible Double Beam Spectrophotometers, Water Activity Meters, Refractometer, Tintometers, ELISA, Auto-Titrators, FTIR, Rancimat, Real Time PCR, Micro Plate Reader, Nano Drop Spectrophotometer, Viscometer, Pulse NMR, DSC, Microbial Air Samplers, Phase Contrast Microscope, Beta Counting Systems, ZnS(Ag), Scintillation Detector, Gamma Detectors Automated, PM10 & PM2.5 E BAM Monitor, Particle Size Analyzer, OTR / WVTR Bomb Calorimeter, CHNSO Analyzer, Sulphur Analyzer, Alcolyzer, Colorimeter Karl Fisher Moisture Analyzer, Reflectance Meter, Polarimeter, SPF Analyzer, Primary Standards, Fixed Points of ITS-90 (-196°C t o 660°C), High Temperature Black Body Source, (600-3000)°C, High Precision Radiation Pyrometer (600-3000)°C , High Accuracy Super Thermometer, Resolution 1 mk , High Temperature Metrology Furnace (300-1200)°C , High Precision Variable Temperature Cryostat, (-180 to -80)°C , High Temperature Alumina Block Furnance (600-1800)°C, Multi-Function Calibrator, Multi-Product Calibrator, AC/DC Reference Standards (Primary Level), Rubidium Frequency Standards, (Primary Level, High Current Coils (50 turns upto 6000A)

Submit Lab Request


DISCLAIMER: This Laboratory Profile was provided by the company above.