Top

Incoming Pipes and Piping Laboratory Test Requests

Contract Laboratory has received the following Pipes and Piping Laboratory Test Requests which need to be fulfilled! These Laboratory Test Requests are received from a variety of sources ranging from start-up companies to large, multinational Fortune 500 corporations, international organizations, well-respected universities and government agencies that are actively seeking Independent, Third-Party Pipes and Piping Laboratories to perform their Pipes and Piping Testing, Analysis, Assays, Product Development, Scientific Research Experiments, Inspections, Certifications, and Engineering Projects. If you are a Pipes and Piping laboratory that would like more information on these Pipes and Piping projects, please visit our registration page or call toll us free 1-855-377-6821.

Below are our 50 most recent Pipes and Piping laboratory test requests. Please log in to see more.

17-01149

Pipes and Piping

Environmental toxicology laboratory needed for eco-toxicity testing on a pipe liner to be used in culverts in California.

Submit Response

17-00855

Pipes and Piping

Materials laboratory needed for confirmatory testing of jointing materials for sewer drains to DIN 4062, Cold processable plastic jointing materials for sewerdrains - Jointing materials for prefabricated parts of concrete, requirements, testing and processing

Closed

17-00790

Pipes and Piping

URGENT TESTING Laboratory needed for corrosion testing of metals to ISO 6509 on faucet shanks. ISO 6509-2:2017 specifies assessment criteria and provides guidance related to the corrosion type dezincification for the selection of copper alloys with a mass fraction of zinc >15 %, exposed to fresh, saline, or drinking water. The assessment criteria are based on the exposure tests detailed in ISO 6509

Submit Response

17-00761

Pipes and Piping

Construction materials laboratory needed for plastIcs testing for identification of additives in plastic pipes

Closed

17-00229

Pipes and Piping

LONG TERM. TESTING Petroleum laboratory needed for ISO and ASME Testing: of composite reinforcement to ASME PCC2/ISO 24817Petroleum, petrochemical and natural gas industries -- Composite repairs for pipework -- Qualification and design, installation, testing and inspection, .

Closed

16-02410

Pipes and Piping

Plumbing product developer in North America needs a closet flange (toilet flange) tested for CSA181.1 or ASTM d2661 or the UL corresponding certification.

Closed

16-02364

Pipes and Piping

Metal Fittings company needs microbiology laboratory for biocidial efficacy testing of product surface testing according to EN ISO 22196 and TS EN 15457 standards. We are a fittings company. Our base material is brass. We plate it with first nickel and then chrome. We apply a biocide on chrome layer.

Closed

16-02337

Pipes and Piping

FDA 175.300 and ISO 17025 accredited laboratory needed to test polymeric coating samples for repeat use with food contact, in order to use it to line food processing tanks and pipes.

Closed

16-02025

Pipes and Piping

Laboratory needed for quality control testing of the piping pressure of a piping steel lining

Closed

16-01952

Pipes and Piping

Laboratory needed for ASTM Testing of aggregates used in oil pipeline operations to the following standards ASTM:Cement:ASTM C150 ? Standard specification for Portland cement Aggregates:ASTM ?294, ?295 - Standard Guide for Petrographic Examination of Aggregates for Concrete ASTM C33 - Standard Specification for Concrete Aggregates ASTM C637 -Standard Specification for Aggregates for Radiation-Shielding ConcreteWater:ASTM C1602 - Standard Specification for Mixing Water used in the Production of Hydraulic Cement Concrete.Steel wire:ASTM A82- Standard Specification for Steel Wire, Plain for Concrete ReinforcementEN 10080 ? Steel for the Reinforcement of Concrete. Weldable Reinforcing Steel. General (Option)

Closed

16-01945

Pipes and Piping

Laboratory needed for study on the compatibility of slotted HDPE pipe (for horizontal wells) through a groundwater contaminant plume over time and with variable temperature while injecting steam. The product is multi-phased, consisting of jet fuel, trichloroethylene and stoddard solvent.

Closed

16-01808

Pipes and Piping

Shipping company needs laboratory for hose bend testing of 6 hoses that need doing bending test according to EN1765 standard. Electrically discontinuous Hydrostatic tested, Vacuum tested. Oil Suction and Discharge Hose hose id:12 ID x 30' OAL working pressure Meets BS1435 EN1765,type S15 standard 150# RF Weld Neck Flange on end 1 and 150# lap Joint Floating Flange on end 2 assembly weight:1130 LBS

Closed

16-00580

Pipes and Piping

Fittings company needs India analytical chemistry laboratory for raw material testing: Spectro (Chemical Analysis,) Micro, Mechanical,sand testing( No-Bake and Green sand) and in-coming raw materials testing etc.

Closed

16-00484

Pipes and Piping

Canada Laboratory needed for HDPE Plastic Pipe Testing to American Association of State Highway and Transportation Officials, AASHTO designations: M252 and M294
Plastic Pipes (HDPE)
All tests needed

Closed

16-00452

Pipes and Piping

India Physical laboratory needed for joint testing to test double universal joint for following test conditions
1) Functional Test
2) Double Torque test
3) Fatigue Test.
Test parameter will shared later once you confirm the testing capability for above mentioned tests.

Closed

16-00104

Pipes and Piping

Large piping company needs East Coast North America materials laboratory for ASTM Testing of six o-ring elastomer samples for DMA analysis to measure Glass Transition Temperature (tg values) following ASTM E 1640. Basically I need to dynamically compress the samples at starting temperature of -70 C with 1 hz frequency up to 60 C with 2 c/min heating rate.

Closed

15-02030

Pipes and Piping

Materials Laboratory needed for ASTM Testing of porous pipes to ASTM D638
Tensile Test, Elongations test
Fluid friction coefficient test and
Consistency factor (Cv) test

Closed

15-01931

Pipes and Piping

Contract Lab needed for radioactivity Testing of NORM contaminated piping Need levels of lead 210. Verify Radium 226 is not present

Closed

15-01896

Pipes and Piping

Materials Laboratory needed for ASTM Testing of porous pipes to ASTM D638
Tensile Test, Elongations test
Fluid friction coefficient test and
Consistency factor (Cv) test

Closed

15-01313

Pipes and Piping

Asia Laboratory needed for solvent testing to determine the type of chemical (i.e. acid) to be used and the associated concentration for softening and/or dissolving the calcium carbonate debris (we have a sample, of limited amounts ? approximately 100g) found in a natural gas pipeline, at the fastest time, without less (or any) harm to the pipeline.

We have short-listed the type of chemicals to:-

a) Acetic Acid
b) Formic Acid (together with citric acid or hydrochloric acid)

However, we are open to suggestions of other chemical types that can get the job done, while meeting the above requirements.

We need a quotation as well for below chemical:

1) Acetic Acid ? 3200 litres (3.36 tonnes)

Closed

15-01186

Pipes and Piping

Middle East Mechanical Laboratory needed for pipes testing: test the UPVC pipes according to DIN 8061-8062

Closed

15-00689

Pipes and Piping

Materials Laboratory needed for ISO plastic piping testing to ISO 4437:2007 we would like to perform following test on our pipe manufactured with PE100 material, kindly send us testing charges. Sr. no. Characteristic Unit Requirement Test parameter Test method Table 2 Characteristic of PE compound - Tested in pipe form 1) Resistance to gas constituents h ? 20 80°C 2MPa ISO 4437:07 Annex A 2) resistance to rapid crack propagation (RCP) S4 test (e ? 15min) bar Pc ? 1.5 x MOP with Pc = 3.6 xPcs4 + 2.6 (in bar) 0°C ISO 13477 3) Resistance to slow crack growth h ? 500 80°C 8.0 bar 80°C 9.2 bar ISO 13479 4) Resistance to weathering (non black) -- After weathering E ? 3.5 GJ/m² ISO 16871 Hydrostatic strength of pipe 80°C; ? 1000h ISO 1167 1 & 2 Elongation at break of pipe ? 350% ISO 6259 1& 3 De-cohesion of an electrofusion joint - percentage brittle failure 23°C; ?33.3% ISO 13954,ISO 11413 jointing condition 1 ISO 8085-3 Expecting your quick response.

Closed

15-00581

Pipes and Piping

Bergen County New Jersey physical laboratory needed for tensile strength testing of T shaped weld sample with 1" OD chromoly pipe that is .120" thick. Required tensile strength to break the pipe is calculated to be ~60,000 pounds (~100,000psi).

Closed

15-00060

Pipes and Piping

South Korea Mechanical Laboratory needed for ASME, ASTM, and NACE Mechanical testing of pipe to A522 Type 1.
We will also need to have NACE testing to MR0175.

Is KTR the only recognized lab in South Korea?

Closed

14-01502

Pipes and Piping

Materials laboratory needed to test UPVC fittings for ISO 1452-2 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure

Closed

14-01198

Pipes and Piping

Texas Laboratory needed for Lubricity Testing for O&G Pipe on Pipes. We have a customer who is wanting us to run an independent lubricity test on our Pipe on Pipe product used in Coiled Tubing vs. what they are currently using.

We typically use the below method but are open to better methods.

Method: Each lubricant is tested on the OFI Lubricity Tester. The lubricants were mixed with tap water at a loading of 0.25%, 1.5%, and 3%. The lubricity tester was set to 60 RPM (rotations per minute), and 150 inch-pounds of torque applied to the test block and test ring. The test ran for 5 minutes, and the torque reading of motor was recorded at the end of the 5 minutes. The percent torque reduction is calculated off the motor torque reading of the tap water being the blank value.

% Torque Reduction = Blank ? Lubricant Torque /
(Blank) ? 100

Closed

14-01057

Pipes and Piping

India Materials Laboratory needed for ASTM Testing: Polyester Pipes Testing ( ASTM D2992 )

Closed

14-01010

Pipes and Piping

India or Middle East Mechanical Laboratory needed for mechanical testing of PQR coupon as per below details, PQR Coupon size:- 6? SCH XXS SMLS PIPE PIPE MATERIAL :- API 5L X52 APPLICABLE STANDARDS:- QP-STD R-006 rev-1 , API1104 Test Required: 1. Tensile test:- transverse tensile test as per API1104 2. Macro Examination:- Two Pieces as per QP-STD-R-006 page 15 of 36 ( attached for your reference) 3. Charpy V notch impact test to BS EN 10045:- Three sample sets for three positions as per as per QP-STD-R-006 page 15 of 36 4. CTOD Test to BS 7448: Two sets of sample at three positions as per as per QP-STD-R-006 page 16 of 36 5. All ?weld Tensile Test to BS 876 as per as per QP-STD-R-006 page 15 of 36: Two specimens

Closed

14-00928

Pipes and Piping

UK, USA or Canada Electrical laboratory needed for ISO Testing: electrical conductivity testing to iso 8031:2009

Closed

14-00437

Pipes and Piping

Asia mechanical laboratory needed for SSC Testing. Steel pipe testing to NACE MR0175 for Sulfide stress cracking NACE MR 0175. 250 jts DRL HFRW pipe API 5L X52

Closed

04-0029

Pipes and Piping

US based GMP Lab needed to perform Bioassay for Protease activity for California biopharmaceutical company

Closed

04-0028

Pipes and Piping

Toxicity testing for liquid serum for EPA registration as disinfectant and surfactant. Lab in Western US State preferred.

Closed

04-0027

Pipes and Piping

vibrio cholera testing of mussels for food firm by GMP lab to US FDA requirements

Closed

04-0026

Pipes and Piping

Multinational biopharmaceutical company needs laboratory to perform the following tests in rodents:blood glucose, blood V, blood TH (TSH/T3) and Blood PTH/Ca

Closed

04-0025

Pipes and Piping

Large Canadian pharmaceutical firm needs a contract lab for Raw Materials Testing for Sorbitol that can test for lead and nickel using an AA or ICP instrument. The specifications of the tests are lead, [EP (2.4.10) limit NMT 0.5ppm], and nickel [EP (2.4.15) limit NMT 1ppm]

Closed

04-0024

Pipes and Piping

Disinfectants Effectiveness Study for very large, California based medical device firm

Closed

04-0023

Pipes and Piping

techniques pour l'étalonnage d'une équerre ; la viscosité ... (from firm in Casablanca)

Closed

04-0022

Pipes and Piping

Marine Toxin ( eg Pectenotoxin in shellfish) testing by ISO accredited lab

Closed

04-0021

Pipes and Piping

HPLC Purity and content of phospholipids for California pharmaceutical company

Closed

04-0020

Pipes and Piping

Individual Antibiotic Test in Tea for Consumer

Closed

04-0019

Pipes and Piping

GMP Compliant lab to perform the following: Full Monograph Testing (individual and total) for the following items:·,Magnesium Stearate·,Maltodextin·,Polyethylene Glycol·,Silicon Dioxide,·Stearic Acid·,Croscarmellose Sodium,,Dibasic Calcium Phosphate·,Lactose Monohydrate·, Specific Rotation for Ephedrine HCl·,Diphenhydramine HCl Organic Nitrogenous Bases for a pharmaceutical company

Closed

04-0018

Pipes and Piping

e-tests for mupirocin gram stain for leucocytes, staph and strep

Closed

04-0017

Pipes and Piping

GLP POLARIMETRY TESTING. LAB MUST BE IN CANADA AND MUST CONFIRM TO GLP STANDARDS

Closed

04-0016

Pipes and Piping

GLP Would like to analyse 3 water soluble samples (plant extract to be used as cosmetic ingredients) for their SOD and antiperoxyl activites

Closed

04-0015

Pipes and Piping

Looking for a lab that can certify an all-purpose cleaner for toxicity

Closed

04-0014

Pipes and Piping

GLP repeat dose acute toxicology studies for vaccines.

Closed

04-0013

Pipes and Piping

assess the androgenic activity, in a quantitative fashion, of a single steriod with the trivial name tetrahydrogestrinone(THG) in a pilot scale study. Either an aquatic organism model or rodent model would appear adequate to provide the information desired but other potential testing types will be considered such as in-vitro receptor binding studies. The study should compare the relative androgenicity of THG to a reference compound such as testosterone

Closed

04-0012

Pipes and Piping

Preservative efficacy test to be performed during the following year. Number of samples and products to be determined. Preferred labs in Ireland or UK

Closed

04-0011

Pipes and Piping

Testing of protein toxicity. GLP compliance needed.

Closed

04-0007

Pipes and Piping

Gas Chromatography. Chemical structure by volume of element, analysis of liquids and solids

Closed

04-0006

Pipes and Piping

Pyruvic acid test

Closed

04-0005

Pipes and Piping

Carbon & Oxygen by combustion analysis. Analysis will be performed on a metal powder. Laboratory must be GLP compliant. Prefer Lab in Canada, but not necessary)

Closed

04-0004

Pipes and Piping

The same microorganism has been recovered from two different sources, Need to know if they are the same strain

Closed

04-0002

Pipes and Piping

Quantification of crystalline Hgh

Closed

03-0036

Pipes and Piping

Lab. to have a Radon Test Kits tested in Ontario, Canada

Closed

03-0035

Pipes and Piping

chronic toxicity tests, one in sediment and one in water, for zooplankton. Also, a chronic toxicity test for a benthic invertebrate, the midge for example if available, for water

Closed

03-0034

Pipes and Piping

Canada Consumer Product Safety Textiles laboratory needed for DIN4102(B1) certification in Canada or near by.

Closed

03-0033

Pipes and Piping

Heavy metals testing and FDA extraction testing on printed & folded coupons. (USA)

Closed

03-0032

Pipes and Piping

USA toxicology Laboratory needed for skin irritation/sensitisation testing to ISO 10993-10 on polythene film samples. (UK)

Closed

03-0031

Pipes and Piping

Pharmaceutical Laboratory needed for Residual Moisture Content analysis (e.g. Karl-Fisher analysis ) on lyophilized cake. All excipients in the formulation safely handled under BL 1 conditions. Fast Turn Around Times a must. Laboratory should be in the contiguous United States.

Closed

03-0030

Pipes and Piping

Pharmaceutical Laboratory needed for Osmolality measurements on reconsituted lyophilized formulation. All excipients in the formulation safely handled under BL 1 conditions. Fast Turn Around Times a must. Laboratory should be in the contiguous United States.

Closed

03-0028

Pipes and Piping

Bioanalytical Laboratory needed for Vitamin detection on Fetal Bovine Serum. Following is a list of vitamins and detectable units:
Vitamin B-12 pg/mL
Folic Acid ng/mL
Vitamin B-6 ng/mL
Thiamin B-1 ng/mL
Niacin ug/mL
Vitamin H Biotin pg/mL
Riboflavin B2 ng/mL
Vitamin A Retinol ng/mL
Vitamin C ng/mL
A-Tocopherol ug/mL
Carotene ug/mL

Closed

03-0027

Pipes and Piping

ENvironmental microbiology laboratory needed for environmental mold issues

Closed

03-0025

Pipes and Piping

Microbiology Laboratory needed for Minimum Inhibitory concentration (MIC) determination ,using dilution method

Closed

03-0024

Pipes and Piping

Microbiology Laboratory needed for disinfectant efficacy testing

Closed

03-0023

Pipes and Piping

EPA GLP certified ENvironmental Laboratory needed that is familiar with EPA tests in LA county

Closed

03-0021

Pipes and Piping

ISO Toxicology laboratory needed for In-vitro Toxicology Studies: Cyto-toxicity test to ISO 10993-5

Closed

03-0020

Pipes and Piping

Preclinical Laboratory needed for antiviral assay on coronaviruses using our pharmaceutical product(s)

Closed

03-0018

Pipes and Piping

Contract Service Preclinical Laboratory to perform an IND enabling FDA GLP toxicology study

Closed

03-0017

Pipes and Piping

Consumer Testing for identity testing of capsules

Closed

03-0016

Pipes and Piping

Preclinical Contract Research Organization needed for Periodic platelet testing in rats

Closed

03-0015

Pipes and Piping

Clinical Contract Research Organization needed for clinical blood testing of rifampin levels in pediatric patients' blood

Closed

03-0012

Pipes and Piping

Microbiology Laboratory needed for microbial analysis SB 3112. The test material consisted of only the bacterial spores at a count of 55 x 107 cfu/ml. The tests were run in compliance with the following protocols: 1 USEPA FIFRA;GLP Standards 40 CFR 160 2 USEPA TSCA 40 CFR 792 3 Org. Economic Coop. and Dev. Principles of GLP, Annex 2, C(97)186 4 Japan Ministry of Ag, Forestry & Fisheries, Notification No. 59 Noshan 3850, Director-General of Agricultural Prod. Bureau, 10 Aug 84

Closed

03-0011

Pipes and Piping

Analytical Chemistry Laboratory needed for solvent gas chromatography testing of three solvent samples for assay analysis on GC ASAP. Product is very pure ethly lactate.

Closed

03-0010

Pipes and Piping

FDA Extraction Test on furnished litho printed coupon paper. Also to do heavy metals testing onfurnished litho inks

Closed

03-0009

Pipes and Piping

bioanalytical laboratory needed for bioanalytical testing done on a drug call serostim (hgh)

Closed

03-0007

Pipes and Piping

Preclinical toxicology laboratory needed for Cytotoxicity studies: MEM Elution Sample Amount: 120 cm2 or 4 grams Irritation: Intracutaneous Reactivity (ISO) (w/2 extracts) Sample Amount: 240 cm2 or 8 grams Sensitization: Magnusson-Kligman (w/2 extracts) Sample Amount 600 cm2 or 32 grams (6 samples minimum) Sensitization: Local Lymph Node Assay: Sample Amount 400 cm2 or 20 grams

Closed

03-0006

Pipes and Piping

Micrbiology Laboratory needed for Microbial Barrier Properties Analysis on Packaging Material

Closed

03-0005

Pipes and Piping

Dietary SUpplement Mfg needs FDA analytical chemistry laboratory that can extract herbs supplied by my company of up to 25 times concentration (25:1)

Closed

03-0004

Pipes and Piping

University needs Wisconsin Microbiology laboratory TOC (Total Organic Carbon) testing for water analysis on water samples

Closed

03-0002

Pipes and Piping

Microbiology Laboratory needed for Microbiology Analysis (Total Plate Count, Yeast, Mold, E. Coli, Salmonella) for 78 Raw Materials

Closed

Submit Pipes and Piping Testing Requests for Pipes and Piping testing and Pipes and Piping Scientific Research