Incoming Oil, Petroleum and Gas Laboratory Test Requests

Contract Laboratory has received the following Oil, Petroleum and Gas Laboratory Test Requests which need to be fulfilled! These Laboratory Test Requests are received from a variety of sources ranging from start-up companies to large, multinational Fortune 500 corporations, international organizations, well-respected universities and government agencies that are actively seeking Independent, Third-Party Oil, Petroleum and Gas Laboratories to perform their Oil, Petroleum and Gas Testing, Analysis, Assays, Product Development, Scientific Research Experiments, Inspections, Certifications, and Engineering Projects. If you are a Oil, Petroleum and Gas laboratory that would like more information on these Oil, Petroleum and Gas projects, please visit our registration page or call toll us free 1-855-377-6821.

Below are our 50 most recent Oil, Petroleum and Gas laboratory test requests. Please log in to see more.

15-00277

Oil, Petroleum and Gas

Toxicology Research Laboratory needed for environmental toxicology study for Metals: Cu, Zn, As, Pb y Cd
on the muscular tissue of freshwater fish (trout)
N° Samples: 25

Closed

15-00266

Oil, Petroleum and Gas

Asia Oil Laboratory needed for ASTM Fuel Testing to detect the Sulfur content in diesel.
Number of Samples - 05

Closed

15-00214

Oil, Petroleum and Gas

MULTIPLE LABS NEEDED: Large Oil company needs midwest usa laboratories for unwashed gum test for gasoline. There will be multiple samples for each location.

Need labs in:
Iowa, Nebraska, Missouri, Oklahoma, Minnesota, Kansas, Wyoming, South Dakota, Idaho, and Montana.

Closed

15-00137

Oil, Petroleum and Gas

Tristate / New England USA oil laboratory needed for gasoline testing for : gasoline octane, ethanol and water content

Closed

15-00126

Oil, Petroleum and Gas

India materials laboratory needed for ASTM Testing: crude oil testing

Closed

15-00063

Oil, Petroleum and Gas

India analytical chemistry laboratory needed for ASTM, EN and ISO biodiesel testing of biodiesel production evaluation from fleshing oil want to carry out transesterification reaction and to characterize the biodiesel produced.

Closed

15-00024

Oil, Petroleum and Gas

Europe independent laboratory needed to conduct C14 testing via spectrometer

Closed

14-01586

Oil, Petroleum and Gas

Large Oil company neededs USA analytical chemistry laoratory for Determination of hydroxyl value by spectroscopy

Closed

14-01540

Oil, Petroleum and Gas

USA materials laboratory needed for Fluid compatibility testing of elastomeric gasket material against a specific grade of kerosene to Exxon Mobil Global Practice 06-05-01:?The Vendor shall either verify that the gasket and glue material are compatible with the specified fluids, including chemical cleaning fluids, or submit proof that verification was performed in the past. In either case, the verification shall be performed by the execution of the following two tests:a) An immersion test to measure gasket swelling, hardness, and susceptibility to chemical attack. The test shall be conducted at the design temperature, and a piece of the specified gasket shall be bonded by the specified adhesive to a piece of the specified plate. The minimum duration of this test shall be 15 days. The gasket hardness change shall not exceed 10 IRHD (International Rubber Hardness Degree), and the volume change shall not be more than 10 percent.b) A compression set test taken on a gasket section compressed to the operational dimension at the upper working temperature of the elastomers. The test shall be done over a 15-day period with compression set measurement taken over 10 cycles. The pass/fail compression is 2 percent. These requirements may be waived if Vendor has at least two years of successful operating experience involving the same gasket, the same adhesive, the same process fluids and conditions, and the same gasket supplier.?

Closed

14-01527

Oil, Petroleum and Gas

Europe ISO/IEC 17025 accredited laboratory needed for ASTM and DIN Testing of Hydraulic oils (HLP and HVLP) to be tested under requirements of DIN 51562-1, DIN 51562-2 and requirements of Bosch Rexroth AG

Closed

14-01511

Oil, Petroleum and Gas

Analytical Chemistry lab needed for Asphaltene Testing. Please specify the rate.

Closed

14-01441

Oil, Petroleum and Gas

Pakistan chemical test lab needed for petrochemical testing

Closed

14-01361

Oil, Petroleum and Gas

Canada ISO bioanalytical laboratory needed forbioanalytical research study for Evaluation of the effect of crude oil contaminants as in-vitro endocrine disruptor and cell proliferation
This research will evaluates the potential endocrine disruptor activity of substances by measuring whether and to what extent a substance induces cell proliferation via estrogen receptor (ER), androgen receptor (AR) (PR) dependent pathways. This research is aimed at screening of test samples to quantify functional activities, either agonist or antagonist, that they may exert against the human androgen receptor and estrogen (ER?) estrogen (ER?).
We shall assay for the following:
1. Agonist dose-response of the AR Reporter Assay
2. Antagonist dose-response of the AR reporter Assay
3. Human ER? and ER? Agonist assays
4. Human ER? antagonist
5. Human ER? antagonist Assay
the statistical analysis shall be carried out as outline below.
Average relative light units (RLU) and corresponding standard deviation (SD) values will be determined for each model concentration (n ? 6). Signal-to-background (S/B) and Z? values will be calculated using Hill?s equation as described by Zhang, et al. (1999a). Non-linear regression and regression analysis, inhibitory concentration (IC50) as well as (Ki) and effective concentration (EC50) analysis will be performed using GraphPad Prism version 6 software. Low percentage coefficient of variation (% CV), high S/B and Z scores will confirm the robust performance of this Assay.

Closed

14-01352

Oil, Petroleum and Gas

Europe analytical chemistry laboratory needed for GC analyses in oil products that we sample from groundwater tables (environmental investigation)

We need fingerprint analysis for product identification. Also, we need to estimate the age of the product.

Closed

14-01351

Oil, Petroleum and Gas

Large multinational corporation needs physical laboratory for Environmental Stress Testing: Run a combined vibration with heat temperature for 20 g-rms random vibration 5-500 Hz. Temperature up to 165 deg C.

Closed

14-01336

Oil, Petroleum and Gas

REQUEST FOR QUOTE quote for OECD Testing to OECD 301B & 306 to run lubricant grease along with the results timeline.

Closed

14-01296

Oil, Petroleum and Gas

Compressor manufacturer needs India ISO Laboratory for oil testing of Oil Content & dust particle to ISO 8573-1, content ta the out of compressor package as per standard ISO 8573-1 class 1 & 1 respectively for dust & oil content after the filter

Closed

14-01281

Oil, Petroleum and Gas

Oil Laboratory for crude oil testing on following:
Asphaltenes ASTM D6560;
Flash point ASTM D56:
Total sulfur, mercaptanes, H2S - UOP 163;
Total nitrogen ASTM D4629;
Bromine number ASTM D1159;
Heat of cumbustion ASTM D240;
Ashes - ASTM D482;
Metals - ASTM D5708, D5863, IP-501;
Chlorides - ASTM D4929, UOP 779, UOP 588;
Organic chlorine;
Wax content;
Atmospheric and vacuum distillation D2892, D5236, D86, D1160;
Acid number;
Vapor pressure;

In addition to that we need GC or GC-MS testing of light petroleum distillate.

Number of samples of crude oil right now could be 15-25 per month, petroleum distillate - 5-8 per month.

Please respond with quotations for any tests you may do for us, and please indicate time around and a sample size required.
Thanks!

Closed

14-01249

Oil, Petroleum and Gas

University Researcher needs Africa oil laboratory for ethanol emission test

Closed

14-01230

Oil, Petroleum and Gas

USA or South America Laoratory needed for petrochemical testing: 1- isotopes ( total crude, saturates, aromatics ) 460 samples

2- analysis of extended diamantoids ( QEDA ) 96 samples

3- Analysis of bio markers with double spectrometry of masses ( AGC-MS-MS) 90 samples

4- IRGC-MS (CSIA-B) of isolated bio markers ( hop and and strange fracts) 90 samples

5- IRGC-MS (CSIA-D) of isolated diamondoids for oil samples plus:
90 samples
Tomografía de nucleos.
Core Gama
Fotografia Visible y UV.

18.000 to 50k feet of nucleos

Closed

14-01187

Oil, Petroleum and Gas

India Laboratory with ISO 17025 accreditation needed for oil filter testing

Closed

14-01178

Oil, Petroleum and Gas

USA Materials laboratory needed for diesel fuel testing to JFTOT ASTM D3241 testing #2 ULSD #2 <15 ppm sulfur diesel fuel
3-5 samples

Closed

14-01108

Oil, Petroleum and Gas

Eastern European Laboratory needed for natural gas testing: gross/high calorific value of natural gas

Closed

14-01070

Oil, Petroleum and Gas

Offshore Oil company needs South Africa oil laboratory to Test 70tons of newly manufactured bentonite and certify it to API std.

Closed

14-01067

Oil, Petroleum and Gas

Oil laboratory needed for propane testing for ethyl mercaptan.

Closed

14-01045

Oil, Petroleum and Gas

Eastern USA analytical chemistry laboratory needed for lubricity testing of race fuel, also possible GCMS analysis.

Closed

14-00939

Oil, Petroleum and Gas

Europe analytical chemistry laboratory needed for ASTM Testing: Petrochemical testng for Propane analysis for petrochemical use

Closed

14-00699

Oil, Petroleum and Gas

EPA GLP laboratory needed for OECD biodegradability testing of lubricant(grease) biodegradation test using OECD 301 or OECD 302 method. I am anxious for the lab information and very appreciated for your help.

Closed

14-00693

Oil, Petroleum and Gas

UAE analytical chemistry laboratory needed for hydrocarbon testing.

Closed

14-00682

Oil, Petroleum and Gas

Oil Exploration Company needs India analytical chemistry laboratory for chemical Analysis of Amine and Glycol samples1. LEAN AMINE: Amine % weight, Water % weight, contamination , Type and % weight, H2S in Amine, CO2 in amine, Foam test, Iron content, pH, salt content.
2.RICH AMINE : Amine % weight, Water % weight, contamination , Type and % weight, H2S in Amine, CO2 in amine, Foam test, Iron content, pH, salt content.
3. LEAN GLYCOL: MEG -% weight, DEG - % weight, TEG - % weight, Water content - % wt, Hydrocarbon content - % weight, salt content as nacl ppm; suspended solid content - % weight; iron content - ppm; foam test; acidity as CH3COOH - % mass; Neutralize value mg KOH/gm; Miscibility with water, pH.
4.RICH GLYCOL-1: MEG -% weight, DEG - % weight, TEG - % weight, Water content - % wt, Hydrocarbon content - % weight, salt content as nacl ppm; suspended solid content - % weight; iron content - ppm; foam test; acidity as CH3COOH - % mass; Neutralize value mg KOH/gm; Miscibility with water, pH.
5.RICH GLYCOL-2: MEG -% weight, DEG - % weight, TEG - % weight, Water content - % wt, Hydrocarbon content - % weight, Amine % weight, salt content as nacl ppm; suspended solid content - % weight; iron content - ppm; foam test; acidity as CH3COOH - % mass; Neutralize value mg KOH/gm; Miscibility with water, pH.

Closed

14-00674

Oil, Petroleum and Gas

University Researcher needs Middle East analytical chemistry laboratory needed for Transmission electron microscopy TEM testing for 6 samples

the samples are solid polyethylene filled with nanoparticles

how much the cost per sample?

Closed

14-00645

Oil, Petroleum and Gas

Middle East Crude Oil trading company needs Middle East materials laboratory for crude oil testing. client and to improve the product specification in case required to meet the international minimum requirement of such product

Closed

14-00636

Oil, Petroleum and Gas

Analytical chemistry laboratory needed for natural gas testing: Test natural gas samples for sulfur compounds, volatile organic compounds, and siloxanes. If you do so, do you have a price quote and what are your reporting limits?

Closed

14-00633

Oil, Petroleum and Gas

ISO Analytical CHemistry Laboratory needed for biodiesel testing: samples 10. performance test and emmision test

Closed

14-00613

Oil, Petroleum and Gas

Oil Laboratory needed for GPA 2286 extended analyses: field sampling and laboratory analyses of natural gas samples taken at tailgates of selected gas processing plants and selected pipeline interconnects. Total of 28 samples staged over a 4-week period."

Closed

14-00605

Oil, Petroleum and Gas

Materials laboratory needed for wax testing for paraffin wax for oil content and usage. please advise price and location. how much wax should be sent for testing?

Closed

14-00599

Oil, Petroleum and Gas

Texas oil laboratory needed for ASTM Testing: landfill gas Testing of petrochemicals to
ASTM 1946M
ASTM D5504
ASTM D6667

Closed

14-00583

Oil, Petroleum and Gas

Analytical Chemistry Laboratory needed for ASTM Testing: complex analysis of crude oil samples, such as distillations, total sulfur, mercaptan, GC hydrocarbons, naphtalene, nitrogen, flash point, asphaltene, density and others...
Please let me know the prices for multiple samples. I expect 30-40 samples per month or more.

Closed

14-00567

Oil, Petroleum and Gas

Oil laboratory needed for fluid characterization testing tocharacterize fluids from oil & gas operations in order to complete SDS information sheets. Below is a list of analytical that we may look for in some or all of the fluids. Fluids include oil, condensate, gas, and produced water.

Crude Oil, Petroleum 8002-05-9
(as Petroleum distillates) 8002-05-9
(as Oil Mist, mineral) 8012-95-1
Benzene 71-43-2
Ethylbenzene 100-41-4
Toluene 108-88-3
Xylene (mixed isomers) 1330-20-7
1, 2, 4-Trimethylbenzene 95-63-6
Butane 106-97-8
Cumene 98-82-8
Hydrogen Sulfide 7783-06-4
Heptane 142-82-5
Isopentane 78-78-4
Pentane 109-66-0
N-Hexane 110-54-3
Nephthalene 91-20-3
Octane 111-65-9
Sulfur 7704-34-9

Physical State:
Appearance:
Color:
Odor:
Odor Threshold:
Flash Point:
Flammability:
Lower Flammability Limit:
Upper Flammability Limit:
Melting Point:
Initial Boiling Point:
Boiling Point:
Freezing Point:
Evaporation Rate:
Density:
Relative Density:
Vapor Pressure:
Vapor Density:
Viscosity:
Solubility:
Specific Gravity:
Auto-Ignition Temperature:
Decomposition Temperature:
pH:
Coefficient of Water/Oil Distribution:
Partition Coefficient: n Octonal/Water:
Percent Volatile, wt. %:
VOC Content, wt. %:

Closed

14-00544

Oil, Petroleum and Gas

Large Oil Compay needs Materials Laboratory for ANSI / SF Testing 4 samples
Water filtration sump to be tested per the ANSI/NSF 42-2000 standard. Section 6.6.6.3 cyclic pressure. The system shall be tested with the outlet plugged after it has been purged of ail. The water temperature shall be 20 C +/- 3C (68 F +/- 5F). The cycle time between the low and high pressure shall be no less than 1 second.section 6.6.1.2 Systems shall be watertight when tested in accordance with 6.6.6.3 after completion of 100,000 cycles at a pressure of 0 to 1040 kPa (0 to 150 psig)

Closed

14-00543

Oil, Petroleum and Gas

Oil Laboratory needed for International Petroleum Test Method testing: 5 samples
HH60,HH100, HH200, HH300 and HH500 tested to IP 346, Determination of polycyclic aromatics in unused lubricating base oils and asphaltene free petroleum fractions - Dimethyl sulphoxide extraction refractive index method

Closed

14-00413

Oil, Petroleum and Gas

University Researcher needs mechanical laboratory for biodiesel testing of the wear characteristics of the Bio-dieselin the Four ball wear testing machine at three different speeds ( 400 to 1500 rpm) , With Scanning Electron microscope testing. So I request you to give me a permission to do the experiments, Send me the quotations for the requirements. ASTM D4172 STANDARD Number of Samples -------- 15 No's Speed Variation -------- (600, 900, 1200) Load -------- 40kg Temperature -------- 75 C Requirements 1. Report of 15 Sampels 2. Microscopic testing report. [ Scanning Electron Microscope ]

Closed

14-00397

Oil, Petroleum and Gas

India mechanical laboratory needed for biodiesel testing of the wear characteristics of the Bio-diesel in the Four ball wear testing machine at three different speeds ( 400 to 1500 rpm) , With Scanning Electron microscope testing. So I request you to give me a permission to do the experiments, Send me the quotations for the requirements.

ASTM D4172 STANDARD

Number of Samples -------- 15 No's
Speed Variation -------- (600, 900, 1200)
Load -------- 40kg
Temperature -------- 75 C

Requirements

1. Report of 15 Sampels
2. Microscopic testing report.
[ Scanning Electron Microscope ]

Closed

14-00390

Oil, Petroleum and Gas

Asia materials laboratory needed for wax testing.

Closed

13-00743

Oil, Petroleum and Gas

Oil Laboratory needed for lubricant testing some of our most commonly used lubricant additives in brine base drilling fluids. The lubricants consist of various blends of esters, glycols, fatty acids, hydrocarbon (diesel) and emulsifiers. The purpose is to determine which lubricant performs the best at reducing the coefficient of friction between metal to metal and metal to formation and the optimal concentrations of each. At the same time, and perhaps more importantly, I would like to evaluate what kind of contaminants and at what concentrations cause "greasing" effects. I would also like to look at miscibility or emulsion of the lubricant in a brine solution and the role this plays on lubricity. Lastly, how do the lubricants hold up when examining formation damage/permeability reduction and to what extent this damage is increased when lubricants eventually grease out.

Closed

13-00738

Oil, Petroleum and Gas

Norway Petroleum Laboratory needed for Hydrocarbon Development Testing and Training programs

Closed

13-00727

Oil, Petroleum and Gas

USA EPA Laboratory needed for VALAP Certification Testing: Btu testing of #2 fuel oil (EPA Method D240 or equivalent) - prefer Northern Virginia location

Closed

13-00668

Oil, Petroleum and Gas

USA Oil Laboratory needed for R &D Testing: Research on Automotive Transmission Fluid ( ATF and any kind of ATF)If we put into the engine ( transmission fluid replace motor oil ) would harm the engines when we run the vehicles about 1-3 weeks . (we can use anykind of ATF for test )

Closed

13-00658

Oil, Petroleum and Gas

USA, Canada Oil Laboratory needed for ASTM Testing: CHNS and BTU in reduced crude oil matrix Typical is ASTM procedures with reference to traceability

Closed

13-00600

Oil, Petroleum and Gas

Middle East Oil Laboratory needed for ASTM Testing: fuel testing, oil testing and natural gas analyisi Distillate Oil -ASTM D 240 Heat of Combustion & ASTM D 5291 (Hydrogen, Carbon and Nitrogen)
Natural Gas - ASTM D 1945 Composition of Natural Gas & ASTM D3588 Heating Value, Compressibility
Other analysis methods may be used if they are equivalent.

Closed

13-00574

Oil, Petroleum and Gas

USA or Canada Oil Laboratory needed for ASTM Testing of oil to ASTM standards: astm d445 40deg c.
astm d445 100 deg c.
astm d2270
astm d287
astm d92
astm d97
astm d4172
astm d943
astm d2272
astm d877
astm d665a
astm d665b
astm 892
astm d130
astm dd2711
astm d5864
astm d6866

Closed

Submit Oil, Petroleum and Gas Testing Requests for Oil, Petroleum and Gas testing and Oil, Petroleum and Gas Scientific Research